Have a question about the Sanyo MPR-1411? The AI assistant looks through this manual and shows the pages with the answer.
Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all refrigerator manuals on this site that print the same figure.
| Fridge factory setting | 5oC warmer than mostfactory chamber temperature settingTypical for refrigerators: 37 to 39 °F (3 to 4 °C) | p. 17 |
|---|---|---|
| Fridge adjustment range | between 2 and 23oCavailable chamber temperature setting rangeTypical for refrigerators: 36 to 46 °F (2 to 8 °C) | p. 17 |
| Door-open alarm after | 2 minutesinitial factory settingTypical for refrigerators: 1 to 5 minutes | p. 19 |
| Defrost | Cycle defrostForced defrostWhen cycle defrost is insufficient | p. 22 |
Sanyo MPR-1411 questions
Answers taken from this manual. Each one links to the page it comes from.
What are the chamber’s factory setting and adjustment limits?
The factory setting is 5oC; the available range is between 2 and 23oC, and partial freezing may occur below 3oC.
Manual: page 17
How much space should I leave around the refrigerator?
Leave at least 10 cm around the unit for ventilation.
Manual: page 13
How do I level the refrigerator after positioning it?
- Rotate the leveling feet counterclockwise until they contact the floor.
- Check that the unit is level.
Manual: page 14
When might the refrigerator need forced defrosting?
High humidity or storing much damp product can leave evaporator frost that cycle defrost does not remove; forced defrost can then be initiated.
Manual: page 22
What does dF mean during defrosting?
A forced defrost cycle is running; the display alternates the chamber temperature with dF, and temperature rises about 10oC.
Manual: page 22
Which error code appears when several alarms happen?
The lowest-numbered error code appears when multiple alarm conditions occur simultaneously.
Manual: page 23
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| E01 | Thermal sensor is short circuited. | p. 23 | |
| E02 | Thermal sensor is disconnected. | p. 23 | |
| E03 | Defrost sensor is disconnected. | p. 23 | |
| E04 | Defrost sensor is short circuited. | p. 23 | |
| E05 | Compressor sensor is disconnected. | p. 23 | |
| E06 | Compressor sensor is short circuited. | p. 23 | |
| E09 | Battery switch was turned on before required setup. | Turn off the battery switch and perform the setting procedure. | p. 23 |
| E10 | Cooling compressor fan motor has failed. | p. 23 | |
| F-1 | Battery replacement is due after approximately three years. | Replace the battery. | p. 23 |
| F-2 | Fan motor replacement is due after approximately six years. | Replace the fan motor. | p. 23 |
Sanyo MPR-1411 compared with other brands
Refrigerators from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Sanyo MPR-1411 | Samsung RR39A7463AP | Marvel 80RDE | Whirlpool Refrigerator | |
|---|---|---|---|---|
| Fridge factory setting | 5oC | 3 °C (37 °F) | 38 °F (3 °C) | 37 °F (3 °C) |
| Fridge adjustment range | between 2 and 23oC | 7 °C and 1 °C (45 °F, 34 °F) | 33° to 47 °F (8 °C) | 33 °F to 45 °F (0 °C to 7 °C) |
| Door-open alarm after | 2 minutes | more than 2 minutes | over 5 minutes | 5 minutes |
Similar Sanyo refrigerators
| Sanyo MPR-1013Model family MPR1 | Instruction Manual | 28 pages |
|---|---|---|
| Sanyo MPR-514Model family MPR | User Manual | 45 pages |
| Sanyo MPR-514RModel family MPR | Instruction Manual | 45 pages |
| Sanyo MPR-214FModel family MPR | Instruction Manual | 35 pages |
| Sanyo MPR-414FModel family MPR | Instruction Manual | 29 pages |
| Sanyo MPR-411FModel family MPR | Instruction Manual | 24 pages |
| Sanyo MPR-311Model family MPR | User Manual | 20 pages |
| Sanyo MBR-1404G | Instruction Manual | 26 pages |