Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all refrigerator manuals on this site that print the same figure.

Fridge factory setting5oC warmer than mostfactory chamber temperature settingTypical for refrigerators: 37 to 39 °F (3 to 4 °C)p. 17
Fridge adjustment rangebetween 2 and 23oCavailable chamber temperature setting rangeTypical for refrigerators: 36 to 46 °F (2 to 8 °C)p. 17
Door-open alarm after2 minutesinitial factory settingTypical for refrigerators: 1 to 5 minutesp. 19
DefrostCycle defrostForced defrostWhen cycle defrost is insufficientp. 22

Sanyo MPR-1411 questions

Answers taken from this manual. Each one links to the page it comes from.

What are the chamber’s factory setting and adjustment limits?

The factory setting is 5oC; the available range is between 2 and 23oC, and partial freezing may occur below 3oC.

Manual: page 17

How much space should I leave around the refrigerator?

Leave at least 10 cm around the unit for ventilation.

Manual: page 13

How do I level the refrigerator after positioning it?
  1. Rotate the leveling feet counterclockwise until they contact the floor.
  2. Check that the unit is level.

Manual: page 14

When might the refrigerator need forced defrosting?

High humidity or storing much damp product can leave evaporator frost that cycle defrost does not remove; forced defrost can then be initiated.

Manual: page 22

What does dF mean during defrosting?

A forced defrost cycle is running; the display alternates the chamber temperature with dF, and temperature rises about 10oC.

Manual: page 22

Which error code appears when several alarms happen?

The lowest-numbered error code appears when multiple alarm conditions occur simultaneously.

Manual: page 23

Error codes in this manual

CodeMeaningWhat to do
E01Thermal sensor is short circuited.p. 23
E02Thermal sensor is disconnected.p. 23
E03Defrost sensor is disconnected.p. 23
E04Defrost sensor is short circuited.p. 23
E05Compressor sensor is disconnected.p. 23
E06Compressor sensor is short circuited.p. 23
E09Battery switch was turned on before required setup.Turn off the battery switch and perform the setting procedure.p. 23
E10Cooling compressor fan motor has failed.p. 23
F-1Battery replacement is due after approximately three years.Replace the battery.p. 23
F-2Fan motor replacement is due after approximately six years.Replace the fan motor.p. 23
All Sanyo error codes →

Sanyo MPR-1411 compared with other brands

Refrigerators from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Sanyo MPR-1411Samsung RR39A7463APMarvel 80RDEWhirlpool Refrigerator
Fridge factory setting5oC3 °C (37 °F)38 °F (3 °C)37 °F (3 °C)
Fridge adjustment rangebetween 2 and 23oC7 °C and 1 °C (45 °F, 34 °F)33° to 47 °F (8 °C)33 °F to 45 °F (0 °C to 7 °C)
Door-open alarm after2 minutesmore than 2 minutesover 5 minutes5 minutes

Similar Sanyo refrigerators

Sanyo MPR-1013Model family MPR1Instruction Manual28 pages
Sanyo MPR-514Model family MPRUser Manual45 pages
Sanyo MPR-514RModel family MPRInstruction Manual45 pages
Sanyo MPR-214FModel family MPRInstruction Manual35 pages
Sanyo MPR-414FModel family MPRInstruction Manual29 pages
Sanyo MPR-411FModel family MPRInstruction Manual24 pages
Sanyo MPR-311Model family MPRUser Manual20 pages
Sanyo MBR-1404GInstruction Manual26 pages
All Sanyo refrigerators →