Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all ice maker manuals on this site that print the same figure.
| Water supply pressure | 20 to 100 psi (138 to 690 kPa)Water supply for the ice maker | p. 3 |
|---|
True TCIM-422-FA1-A~*-# questions
Answers taken from this manual. Each one links to the page it comes from.
What water pressure does the ice maker need?
20-100 psig (138-689 kPa) is the required water supply pressure.
Other brands: Scotsman 20 to 80 psi (138 to 552 kPa) · Marvel 20 to 80 psi (138 to 552 kPa) · Whirlpool 30 to 120 psi (207 to 827 kPa) Compare all
Manual: page 3
What should I verify after installing the water filter?
Verify the filter is installed and the ice maker has the correct water filter capacity setting.
Manual: page 3
How do I remove the front panel?
- Remove the front panel screws.
- Open the front panel or panels.
Manual: page 41
When should I sanitize the ice machine?
What dilution should I use for non-TRUE descaler?
For non-TRUE Nickel-safe descaler, use these amounts and never mix descaler with sanitizer.
- Soaking parts: 3 fl oz (88.7 ml) per 1 gal (3.78 L).
- Evaporator cleaning: 6-8 fl oz (177.4-236.6 ml).
Manual: page 56
How do I enable the TRUE TIME-OF-FLIGHT® (TOF) sensor after powering the ice maker?
Power the unit, then choose a preset that matches the ice storage setup.
- Power the unit.
- On the home screen, press MENU.
- In the MENU screen, press TOF.
- Choose the preset for your ice storage unit.
- If none fits, choose Level 5 - Custom Setup.
Manual: page 49
How do I clear a custom TOF setting?
Choose Level 5 - Custom Setup if the preset options do not fit the application.
- On the custom setting screen, press CLR to clear the current setting.
- Enter the desired setting, then press okay.
Manual: page 50
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| COMM | Display communication error. | p. 93 | |
| E1 | Evaporator outlet temperature probe error. | p. 93 | |
| E2 | Ambient air temperature probe error. | p. 93 | |
| E3 | Sump water temperature probe error. | p. 93 | |
| E4 | Supply water temperature probe error. | p. 93 | |
| E6 | High pressure safety switch is open. | p. 93 | |
| E7 | High pressure transducer error. | p. 93 | |
| E8 | Low pressure transducer error. | p. 93 | |
| E9 | Water level sensor input error. | p. 93 | |
| E10 | Ice level sensor communication error. | p. 93 | |
| E11 | Evaporator outlet temperature is too low during freezing. | p. 93 | |
| E12 | Evaporator outlet temperature is too high. | p. 93 | |
| E13 | Evaporator outlet temperature is too low. | p. 93 | |
| E14 | Ambient air temperature is too high. | p. 93 | |
| E15 | Ambient air temperature is too low. | p. 93 | |
| E16 | Sump water temperature is too high. | p. 93 | |
| E17 | Sump water temperature is too low. | p. 93 | |
| E18 | Supply water temperature is too high. | p. 93 | |
| E19 | Supply water temperature is too low. | p. 93 | |
| E20 | High pressure detected at the high pressure transducer. | p. 93 | |
| E21 | Drain switch alarm. | p. 93 | |
| E22 | Freeze cycle takes too long. | p. 93 | |
| E23 | Calculation produced a negative value. | p. 93 | |
| E24 | Fill cycle takes too long. | p. 93 | |
| E25 | Purge cycle takes too long. | p. 93 | |
| E26 | Harvest cycle takes too long. | p. 93 | |
| E27 | Water leakage detected. | p. 93 | |
| E28 | Pump motor alarm. | p. 93 | |
| E30 | Biozone communication or bulb problem. | Check communication or replace the bulb. | p. 93 |
| E31 | Hot gas valve alarm. | p. 93 | |
| E32 | Low suction pressure. | p. 93 | |
| H2O | Water fill is slow. | Check the water connection. | p. 93 |