True error codes
69 True error and alarm codes from 11 manuals: what each code means and what the manual says to do.
69 codes11 manuals
Codes and what they mean
As described in each manual. The same code can mean different things on different models, so check the model column.
| Code | Meaning | What to do | Manual |
|---|---|---|---|
| COM | Display is not communicating with the control board. | Check display and board connections; the unit may need a firmware update. | TCIM-422-FA1-A~*-# |
| COMM | Display communication error. | TCIM-422-FA1-A~*-# | |
| dA | Door switch alarm. | TRM2L******#*******#, Commercial Refrigerator | |
| dEF | Defrost is in progress. | TRM2L******#*******#, Commercial Refrigerator, TGO-27-POP01, TGO-27-POP01 | |
| dEF | Defrost is active | GDM-23-HST02-HC | |
| dEF | Defrost is currently running. | GDM-49-SCI-HC | |
| dLc | Door lock or unlock password entry | TGO-27-POP01, GDM-23-HST02-HC, TGO-27-POP01, GDM-23-HST02-HC | |
| do | Door open alarm | TGO-27-POP01, GDM-23-HST02-HC, TGO-27-POP01, GDM-23-HST02-HC | |
| do | The cabinet door is open. | GDM-49-SCI-HC | |
| do | Door open | Open for ≥ 60 sec | Commercial Refrigerator |
| E1 | Probe t1 failure | TGO-27-POP01 | |
| E1 | Probe 1 has failed | GDM-23-HST02-HC | |
| E1 | Temperature probe 1 has failed. | GDM-49-SCI-HC | |
| E1 | Probe 1 failure | TGO-27-POP01 | |
| E1 | Probe t1 has failed | GDM-23-HST02-HC, GDM-49-SCI-HC | |
| E1 | Evaporator outlet temperature probe error. | TCIM-422-FA1-A~*-# | |
| E1 | T1 probe is open or shorted. | Replace the probe. | TCIM-422-FA1-A~*-# |
| E2 | Probe t2 failure | TGO-27-POP01 | |
| E2 | Probe 2 has failed | GDM-23-HST02-HC | |
| E2 | Temperature probe 2 has failed. | GDM-49-SCI-HC | |
| E2 | Probe 2 failure | TGO-27-POP01 | |
| E2 | Probe t2 has failed | GDM-23-HST02-HC, GDM-49-SCI-HC | |
| E2 | Ambient air temperature probe error. | TCIM-422-FA1-A~*-# | |
| E2 | T2 probe is open or shorted. | Replace the probe. | TCIM-422-FA1-A~*-# |
| E3 | Probe t3 failure | TGO-27-POP01 | |
| E3 | Probe 3 has failed | GDM-23-HST02-HC | |
| E3 | Temperature probe 3 has failed. | GDM-49-SCI-HC | |
| E3 | Probe 3 failure | TGO-27-POP01 | |
| E3 | Probe t3 has failed | GDM-23-HST02-HC, GDM-49-SCI-HC | |
| E3 | Sump water temperature probe error. | TCIM-422-FA1-A~*-# | |
| E3 | T3 probe is open or shorted. | Replace the probe. | TCIM-422-FA1-A~*-# |
| E4 | Supply water temperature probe error. | TCIM-422-FA1-A~*-# | |
| E4 | T4 probe is open or shorted. | Replace the probe. | TCIM-422-FA1-A~*-# |
| E6 | High pressure safety switch is open. | TCIM-422-FA1-A~*-# | |
| E6 | Discharge pressure exceeded 370 psi. | Clean the air filter and condenser coil; verify the condenser fan operates. | TCIM-422-FA1-A~*-# |
| E7 | High pressure transducer error. | TCIM-422-FA1-A~*-# | |
| E7 | HP1 transducer signal is lost or indicates high pressure. | Check transducer wiring to the board; replace the transducer. | TCIM-422-FA1-A~*-# |
| E8 | Low pressure transducer error. | TCIM-422-FA1-A~*-# | |
| E8 | LP1 transducer signal is lost or indicates low pressure. | Check transducer wiring to the board; replace the transducer. | TCIM-422-FA1-A~*-# |
| E9 | Water level sensor input error. | TCIM-422-FA1-A~*-# | |
| E9 | Water level sensor signal is lost. | Check sensor tubing and verify the board pressure chip has good contact. | TCIM-422-FA1-A~*-# |
| E10 | Ice level sensor communication error. | TCIM-422-FA1-A~*-# | |
| E11 | Evaporator outlet temperature is too low during freezing. | TCIM-422-FA1-A~*-# | |
| E11 | T1 fell below minus 10 degrees during the first two freeze minutes. | Check probe resistance and location, pump operation, and whether the previous ice sheet fell. | TCIM-422-FA1-A~*-# |
| E12 | Evaporator outlet temperature is too high. | TCIM-422-FA1-A~*-# | |
| E12 | Evaporator outlet temperature exceeded 113 degrees Fahrenheit. | Verify cold water supply and ambient temperatures; test the probe. | TCIM-422-FA1-A~*-# |
| E13 | Evaporator outlet temperature is too low. | TCIM-422-FA1-A~*-# | |
| E13 | Evaporator outlet temperature fell below minus 20 degrees Fahrenheit. | Test the probe, outlet temperature, pump operation, and water supply. | TCIM-422-FA1-A~*-# |
| E14 | Ambient air temperature is too high. | TCIM-422-FA1-A~*-# | |
| E14 | Ambient temperature exceeded 130 degrees Fahrenheit. | Verify ambient temperature, test the probe, and verify condenser motor operation. | TCIM-422-FA1-A~*-# |
| E15 | Ambient air temperature is too low. | TCIM-422-FA1-A~*-# | |
| E15 | Ambient temperature fell below 33 degrees Fahrenheit. | Verify ambient temperature and test the probe. | TCIM-422-FA1-A~*-# |
| E16 | Sump water temperature is too high. | TCIM-422-FA1-A~*-# | |
| E16 | Water trough temperature exceeded 113 degrees Fahrenheit. | Verify trough water temperature and test the probe. | TCIM-422-FA1-A~*-# |
| E17 | Sump water temperature is too low. | TCIM-422-FA1-A~*-# | |
| E17 | Water trough temperature fell below 25 degrees Fahrenheit. | Verify trough water temperature and test the probe. | TCIM-422-FA1-A~*-# |
| E18 | Supply water temperature is too high. | TCIM-422-FA1-A~*-# | |
| E18 | Incoming water temperature exceeded 124 degrees Fahrenheit. | Check water supply temperature and test the probe. | TCIM-422-FA1-A~*-# |
| E19 | Supply water temperature is too low. | TCIM-422-FA1-A~*-# | |
| E19 | Incoming water temperature fell below 33 degrees Fahrenheit. | Check water supply temperature and test the probe. | TCIM-422-FA1-A~*-# |
| E20 | High pressure detected at the high pressure transducer. | TCIM-422-FA1-A~*-# | |
| E20 | HP1 head pressure exceeded 320 to 360 psi, depending on model. | Clean the air filter and condenser coil; verify proper condenser fan operation. | TCIM-422-FA1-A~*-# |
| E21 | Drain switch alarm. | TCIM-422-FA1-A~*-# | |
| E22 | Freeze cycle takes too long. | TCIM-422-FA1-A~*-# | |
| E22 | Freeze cycle exceeded 40 minutes. | Verify compressor operation and check high and low side pressures. | TCIM-422-FA1-A~*-# |
| E23 | Calculation produced a negative value. | TCIM-422-FA1-A~*-# | |
| E23 | Sump water level fell below the freeze cycle differential. | Check for leaks near the evaporator cover, harvest flap, and drain valve. | TCIM-422-FA1-A~*-# |
| E24 | Fill cycle takes too long. | TCIM-422-FA1-A~*-# | |
| E24 | Sump tank did not fill within 30 minutes. | Verify water supply; check the incoming filter and inlet valve. | TCIM-422-FA1-A~*-# |
| E25 | Purge cycle takes too long. | TCIM-422-FA1-A~*-# | |
| E25 | Sump water did not drain to the proper level within four minutes. | Check drain valve voltage, clear and vent the drain, and check the sump drain. | TCIM-422-FA1-A~*-# |
| E26 | Harvest cycle takes too long. | TCIM-422-FA1-A~*-# | |
| E26 | Bin switch failed to open during three harvests, or startup temperature stayed too low. | Check stuck switch contacts, evaporator freezing, and ice sheet pattern. | TCIM-422-FA1-A~*-# |
| E27 | Water leakage detected. | TCIM-422-FA1-A~*-# | |
| E27 | Water level fell below the harvest initiation level during the first five minutes. | Check excessive splashing, the water curtain, harvest flap, and leaking drain valve. | TCIM-422-FA1-A~*-# |
| E28 | Pump motor alarm. | TCIM-422-FA1-A~*-# | |
| E28 | During startup, water level did not fall below 43 millimeters within 60 seconds. | Check pump voltage and verify the inlet valve shuts off. | TCIM-422-FA1-A~*-# |
| E29 | Sump tank did not fill within three minutes. | Check the water filter, incoming pressure, inlet valve, and drain valve. | TCIM-422-FA1-A~*-# |
| E30 | Biozone communication or bulb problem. | Check communication or replace the bulb. | TCIM-422-FA1-A~*-# |
| E30 | UV Biozone system failure. | Check the UV menu for low current, high current, or exceeded lamp time. | TCIM-422-FA1-A~*-# |
| E31 | Hot gas valve alarm. | TCIM-422-FA1-A~*-# | |
| E31 | High side pressure exceeded 165 psi during harvest. | Follow the No Harvest or Frozen In flow chart. | TCIM-422-FA1-A~*-# |
| E32 | Low suction pressure. | TCIM-422-FA1-A~*-# | |
| E32 | Low side pressure fell below 10 psi during freezing. | Check cycle times, pressures, ice pattern, leaks, and restrictions. | TCIM-422-FA1-A~*-# |
| E33 | Secondary high side transducer failed. | Check transducer wiring to the control board; replace the transducer. | TCIM-422-FA1-A~*-# |
| E34 | Secondary low side transducer failed. | Check transducer wiring to the control board; replace the transducer. | TCIM-422-FA1-A~*-# |
| Edt | End time for timed actions | TGO-27-POP01, TGO-27-POP01, GDM-23-HST02-HC | |
| Edt | End time for scheduled actions | GDM-23-HST02-HC | |
| EE | Data or memory failure. | TRM2L******#*******#, Commercial Refrigerator | |
| H2O | Water fill is slow. | Check the water connection. | TCIM-422-FA1-A~*-# |
| HA | Maximum cabinet temperature alarm. | TRM2L******#*******# | |
| HA | Maximum temperature alarm | Commercial Refrigerator | |
| HA2 | Maximum condenser liquid line temperature alarm. | TRM2L******#*******# | |
| hi | Appliance high temperature alarm | TGO-27-POP01, GDM-23-HST02-HC, TGO-27-POP01, GDM-23-HST02-HC | |
| hi | The cabinet temperature is too high. | GDM-49-SCI-HC | |
| hi | High temperature | ≥ 46 °F (8 °C) for ≥ 5 min | Commercial Refrigerator |
| hi | Cabinet high temperature alarm. | GDM-49-SCI-HC | |
| hLA/Loc | Health Safety Alarm or lockout is active | TGO-27-POP01, GDM-23-HST02-HC, TGO-27-POP01, GDM-23-HST02-HC | |
| hrS | Hours of the real time clock | TGO-27-POP01, TGO-27-POP01, GDM-23-HST02-HC | |
| hrS | Real time clock hours | GDM-23-HST02-HC | |
| hrS | Displays the real time clock hour. | GDM-49-SCI-HC | |
| hrS | Hours shown by the real-time clock. | GDM-49-SCI-HC | |
| hSt | Health Safety Timer password entry | TGO-27-POP01, GDM-23-HST02-HC, TGO-27-POP01, GDM-23-HST02-HC | |
| hSt/dLY | Delays checking Health Safety Timer conditions | TGO-27-POP01, GDM-23-HST02-HC | |
| hSt/dLY | Delays Health Safety Timer condition checks | GDM-23-HST02-HC | |
| hSt/dLY | Delay for checking Health Safety Timer conditions | TGO-27-POP01 | |
| hSt/tSt | Tests the Health Safety Lock | TGO-27-POP01, GDM-23-HST02-HC | |
| hSt/tSt | Health Safety Lock testing | GDM-23-HST02-HC | |
| hSt/tSt | Testing the Health Safety Lock | TGO-27-POP01 | |
| H₂O | Sump tank did not fill within three minutes. | Check the water filter, incoming pressure, inlet valve, and drain valve. | TCIM-422-FA1-A~*-# |
| LA | Minimum temperature alarm. | TRM2L******#*******#, Commercial Refrigerator | |
| Lo | Appliance low temperature alarm | TGO-27-POP01, GDM-23-HST02-HC, TGO-27-POP01, GDM-23-HST02-HC | |
| Lo | The cabinet temperature is too low. | GDM-49-SCI-HC | |
| Lo | Low temperature | ≤ 36 °F (2 °C) for ≥ 5 min | Commercial Refrigerator |
| Lo | Cabinet low temperature alarm. | GDM-49-SCI-HC | |
| Loc | Keypad is locked | Press the down arrow until the display shows Loc. | TGO-27-POP01, GDM-23-HST02-HC, TGO-27-POP01, GDM-23-HST02-HC |
| Loc | The keypad is locked. | GDM-49-SCI-HC | |
| min | Minute of the real time clock | TGO-27-POP01, TGO-27-POP01, GDM-23-HST02-HC | |
| min | Real time clock minute | GDM-23-HST02-HC | |
| min | Displays the real time clock minute. | GDM-49-SCI-HC | |
| min | Minute shown by the real-time clock. | GDM-49-SCI-HC | |
| oFF | Controller is in standby. | Hold the power button until the display shows OFF. | TRM2L******#*******#, Commercial Refrigerator, TGO-27-POP01, GDM-23-HST02-HC |
| oFF | The controller is in standby mode. | GDM-49-SCI-HC | |
| on | Control is turned on | Press and hold Cancel until on appears. | TGO-27-POP01 |
| P1 | Thermostat probe failure. | TRM2L******#*******#, Commercial Refrigerator | |
| P2 | Evaporator probe failure. | TRM2L******#*******#, Commercial Refrigerator | |
| P3 | Auxiliary probe failure. | TRM2L******#*******#, Commercial Refrigerator | |
| PF | Power failure | TGO-27-POP01, GDM-23-HST02-HC, TGO-27-POP01, GDM-23-HST02-HC | |
| PoF | Control is locked. | Hold both arrow buttons until the display shows PoF. | TRM2L******#*******#, Commercial Refrigerator |
| Pon | Control is unlocked. | Hold both arrow buttons until the display shows Pon. | TRM2L******#*******#, Commercial Refrigerator |
| Stt | Start time for timed actions | TGO-27-POP01, TGO-27-POP01, GDM-23-HST02-HC | |
| Stt | Start time for scheduled actions | GDM-23-HST02-HC | |
| t1 | Current probe 1 temperature | TGO-27-POP01 | |
| t1 | Current temperature from probe 1 | GDM-23-HST02-HC | |
| t1 | Shows the current temperature from probe 1. | GDM-49-SCI-HC | |
| t1 | Instant temperature from probe 1 | TGO-27-POP01, GDM-23-HST02-HC | |
| t1 | Instant temperature of probe 1. | Press info to show t1. | GDM-49-SCI-HC |
| t2 | Current probe 2 temperature | TGO-27-POP01 | |
| t2 | Current temperature from probe 2 | GDM-23-HST02-HC | |
| t2 | Shows the current temperature from probe 2. | GDM-49-SCI-HC | |
| t2 | Instant temperature from probe 2 | TGO-27-POP01, GDM-23-HST02-HC | |
| t2 | Instant temperature of probe 2. | GDM-49-SCI-HC | |
| t3 | Current probe 3 temperature | TGO-27-POP01 | |
| t3 | Current temperature from probe 3 | GDM-23-HST02-HC | |
| t3 | Shows the current temperature from probe 3. | GDM-49-SCI-HC | |
| t3 | Instant temperature from probe 3 | TGO-27-POP01, GDM-23-HST02-HC | |
| t3 | Instant temperature of probe 3. | GDM-49-SCI-HC | |
| thi | Maximum recorded probe 3 temperature | TGO-27-POP01, TGO-27-POP01 | |
| thi | Highest recorded probe 3 temperature | GDM-23-HST02-HC | |
| thi | Displays the highest recorded temperature from probe 1. | GDM-49-SCI-HC | |
| thi | Maximum recorded temperature from probe 3 | GDM-23-HST02-HC | |
| thi | Maximum recorded temperature of probe 1. | GDM-49-SCI-HC | |
| tLo | Minimum recorded probe 3 temperature | TGO-27-POP01, TGO-27-POP01 | |
| tLo | Lowest recorded probe 3 temperature | GDM-23-HST02-HC | |
| tLo | Displays the lowest recorded temperature from probe 1. | GDM-49-SCI-HC | |
| tLo | Minimum recorded temperature from probe 3 | GDM-23-HST02-HC | |
| tLo | Minimum recorded temperature of probe 1. | GDM-49-SCI-HC |