Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all ice maker manuals on this site that print the same figure.

Water filter replacementwithin 6 monthsfilter elementTypical for ice makers: 6 monthsp. 18
Water supply pressure22 to 80 psi (150 to 550 kPa)Water supplyp. 6
Clearance at the sidesabove 15cmAir-cooled ice machine, left and right sidesTypical for ice makers: 1 to 6 in (2.5 to 15.2 cm)p. 5
Clearance behindabove 15cmAir-cooled ice machine, backTypical for ice makers: 3 to 6 in (7.6 to 15.2 cm)p. 5
Room temperature range1℃ to 40℃Normal operating ambient temperatureTypical for ice makers: 50 to 100 °F (10 to 38 °C)p. 5

Trufrost IC-100 questions

Answers taken from this manual. Each one links to the page it comes from.

How do I adjust the ice thickness?
  1. Hold △ or ▽ for 3 seconds until C1 appears and the final two digits flash.
  2. Hold △ to add 1 minute, increasing thickness, or ▽ to subtract 1 minute, reducing thickness.
  3. Keep the setting between 0 and 35 minutes.
  4. Wait 10 seconds without operating, or press the cleaning button to save the setting.

Manual: page 12

How should I maintain the ice maker during a long shutdown?

Run the ice maker for 4 to 6 hours every two months during a long shutdown.

Manual: page 10

How often should I clean the air-cooled condenser?

Every three months, brush the condenser fins downward with a soft brush or vacuum brush.

Manual: page 18

How do I level the ice maker after installing its feet?

Adjust the supporting feet until the machine stands firmly and level.

  1. Attach each foot to the machine’s underside.
  2. Fasten every foot securely to prevent bending.
  3. Set the ice maker on a firm, level surface.
  4. Change foot height until the ice maker is level.

Manual: page 5

What do the first button type's E01 through E06 codes mean?

They indicate these faults on the first button type.

CodeFault
E01Condensing temperature sensor failure
E02Water temperature sensor fault
E03Ice falling timeout
E04Water shortage fault
E05High temperature failure
E06Pressure overruns

Manual: page 13

What do the second button type's E07/08, E09/10, and E11 codes mean?

They indicate these faults on the second button type.

CodeFault
E07/08Condensing temperature sensor failure
E09/10Evaporation temperature sensor failure
E11Poor refrigeration effect

Manual: page 15

Error codes in this manual

CodeMeaningWhat to do
E01Condensing temperature sensor failure.Check related parts.p. 13
E02Water temperature sensor fault.Check related parts.p. 13
E03Ice falling takes too long.Check the heating valve, circuit, ice thickness detector, and inlet system.p. 13
E04Insufficient water supply.Check related parts.p. 13
E05Temperature is too high.Check related parts.p. 13
E06Pressure is excessively high.Check refrigeration pressure, condensing system, and cooling system.p. 13
E07Ice plate or full ice switch fault.Check related parts.p. 13
E07/08Condensing temperature sensor failure.Check related parts.p. 15
E09/10Evaporation temperature sensor failure.Check related parts.p. 15
E11Refrigeration performance is poor.Check related parts.p. 15
All Trufrost error codes →

Trufrost IC-100 compared with other brands

Ice Makers from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Trufrost IC-100Scotsman CB0330Follett 15CI114A-NW-**-**-**Other HZB-45A
Water filter replacementwithin 6 monthsmore than 6 months6 months·
Water supply pressure22 to 80 psi (150 to 550 kPa)20 to 80 psi (138 to 552 kPa)10 to 70 psi (69 to 483 kPa)15 to 116 psi (100 to 800 kPa)
Clearance at the sidesabove 15cm6" (15.2 cm)3" (7.62 cm)5 cm (2 in)
Clearance behindabove 15cm6" (15.2 cm)2" (5.08 cm)5CM
Room temperature range1℃ to 40℃50 F. to 100oF50 F (10 C) to 100 F (38 C)above 50 Fahrenheit and below 90Fahrenheit

Similar Trufrost ice makers

Trufrost IC-18BWModel family IC1User Manual11 pages
All Trufrost ice makers →