| Code | Meaning | What to do | Manual |
|---|---|---|---|
| E01 | Condensing temperature sensor failure. | Check related parts. | IC-100 |
| E02 | Water temperature sensor fault. | Check related parts. | IC-100 |
| E03 | Ice falling takes too long. | Check the heating valve, circuit, ice thickness detector, and inlet system. | IC-100 |
| E04 | Insufficient water supply. | Check related parts. | IC-100 |
| E05 | Temperature is too high. | Check related parts. | IC-100 |
| E06 | Pressure is excessively high. | Check refrigeration pressure, condensing system, and cooling system. | IC-100 |
| E07 | Ice plate or full ice switch fault. | Check related parts. | IC-100 |
| E07/08 | Condensing temperature sensor failure. | Check related parts. | IC-100 |
| E09/10 | Evaporation temperature sensor failure. | Check related parts. | IC-100 |
| E11 | Refrigeration performance is poor. | Check related parts. | IC-100 |
| HH | Sensor temperature is above the permitted limit. | Check the cooling system. | 240VAC |
| LL | Sensor temperature is below the permitted limit. | Check whether the controller works properly. | 240VAC |