Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all refrigerator manuals on this site that print the same figure.

Door-open alarm after5 minutesdoor left openTypical for refrigerators: 1 to 5 minutesp. 51
Clearance aboveno additional air spacebuilt-in installationTypical for refrigerators: 1 to 3.9 in (2.5 to 9.9 cm)p. 8
Clearance at the sidesno additional air spacebuilt-in installationTypical for refrigerators: 0.7 to 3.1 in (1.8 to 7.9 cm)p. 8
Clearance behindno additional air spacebuilt-in installation; clearance is required for an electrical connection in the rearno additional air space, electrical connection clearance requiredbuilt-in installationTypical for refrigerators: 1.5 to 3 in (3.8 to 7.6 cm)p. 8
Space to open the doors1/4" (6 mm)side-by-side installationp. 10
Defrostautomaticp. 38
Room temperature range50 °F (10 °C) to 100 °F (38 °C)1215WC indoor/interior applicationsTypical for refrigerators: 50 to 100 °F (10 to 38 °C)p. 6
Sabbath modeYeswhen the unit is cooling but the display or interior light does not workp. 38

U-Line 1215WC questions

Answers taken from this manual. Each one links to the page it comes from.

How do I check the refrigerator’s actual product temperature?

Use a sealed, water-filled bottle and thermometer to measure the product temperature.

  1. Partially fill a plastic, nonbreakable bottle with water.
  2. Put an accurate thermometer inside the bottle.
  3. Tighten the bottle cap securely.
  4. Place the bottle in the area you want to check for 24 hours.
  5. Do not open the unit during testing.
  6. Check the water temperature after 24 hours.
  7. Adjust the temperature control in a small increment if needed.

Manual: page 39

Why is my refrigerator freezing or not cold enough?

Several conditions can affect the refrigerator’s internal temperature.

  • Product touches the rear wall. Move it away from the wall to prevent freezing.
  • Temperature setting is too cold. Adjust it to a warmer set point.
  • Temperature setting is too warm. Adjust it to a cooler set point.
  • Excessive ambient heat or direct sunlight. Relocate the unit away from those conditions.
  • Door, grille, condenser, or light problem. Check the seal, clear the grille, clean the coil, and check the light.

Manual: page 39

What should I do about frost inside the refrigerator?
  • Normal rear-wall frost. No action is needed; it melts during an off cycle.
  • Frost reaches 1/4" or more. Manually defrost the unit.
  • Poor sealing, heat, or humidity. Check the door seal and the surrounding temperature and humidity.

Manual: page 38

Is water dripping into the drain pan during defrost normal?

Yes, water may drip or run into the drain pan during the automatic defrost cycle.

Manual: page 38

What should I check first if the refrigerator is not cooling?

Check airflow around the condenser and clean it if dirty, because compressor overheating can cause no cooling. If the compressor runs without cooling, system diagnosis is required.

Manual: page 49

Is a hum or pulsing sound normal while the refrigerator runs?

Yes, the compressor may make a hum or pulsing sound during operation.

Manual: page 48

Why is the ice maker producing less ice?

Room temperatures above 100 °F (38 °C) can lower ice output; operate the unit between 50 °F (10 °C) and 100 °F (38 °C).

Manual: page 6

What clearance does built-in installation need around the unit?

Built-in placement needs no extra ventilation gap above, beside, or behind the unit. Do not block the front grille, and leave room behind for the electrical connection.

Manual: page 8

How much space is needed between two units installed side by side?

Leave 1/4" (6 mm) between side-by-side units; no trim kit is required.

Manual: page 10

What happens when I view the refrigerator’s error log?

The stored errors scroll once in occurrence order, while only a door error appears on the display and sounds an alert.

Manual: page 55

Error codes in this manual

CodeMeaningWhat to do
E0Upper door 1 is open.p. 55
E1Thermistor 1 is open.p. 55
E2Thermistor 2 is open.p. 55
E3Thermistor 3 is open.p. 55
E4Thermistor 4 is open.p. 55
E5Thermistor 1 is shorted.p. 55
E6Thermistor 2 is shorted.p. 55
E7Thermistor 3 is shorted.p. 55
E8Thermistor 4 is shorted.p. 55
E9Lower door 2 is open.p. 55
P1Pump circuit is open.p. 55
All U-Line error codes →

U-Line 1215WC compared with other brands

Refrigerators from other brands with the most of the same figures in their manuals. Values as printed in each manual.

U-Line 1215WCWhirlpool WRB3504SKitchenAid RefrigeratorHisense HQD20
Door-open alarm after5 minutes2 minutes5 minutes2 minutes
Space to open the doors1/4" (6 mm)350mm2" (5.08 cm) minimum4" (10 cm) minimum
Room temperature range50 °F (10 °C) to 100 °F (38 °C)above 10 °C (50 °F)55 °F (13 °C) to 110 °F (43 °C)55 °F (13 °C) to 110 °F (43 °C)

Similar U-Line refrigerators

U-Line U-3036RRINT-00BService Manual72 pages
U-Line ADA24ROperating Instructions63 pages
U-Line 3018CLRService Manual63 pages
U-Line U-ADA24RGLS-13BService Manual44 pages
U-Line UACR015-SS01AService Manual44 pages
U-Line URNP115-IS01AService Manual33 pages
All U-Line refrigerators →