Have a question about the U-Line FZ124? The AI assistant looks through this manual and shows the pages with the answer.
Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all freezer manuals on this site that print the same figure.
| Clearance above | No additional air spaceBuilt-in installationTypical for freezers: 3 to 5.5 in (7.6 to 14 cm) | p. 8 |
|---|---|---|
| Clearance at the sides | No additional air spaceBuilt-in installationTypical for freezers: 3 to 5 in (7.6 to 12.7 cm) | p. 8 |
| Clearance behind | No additional air spaceBuilt-in installationTypical for freezers: 2 to 5 in (5.1 to 12.7 cm) | p. 8 |
| Space to open the doors | 1/4" (6 mm)Side-by-side installation, between units | p. 9 |
| Defrost | Automatic Defrost | p. 28 |
| Room temperature range | 50 °F (10 °C) and 100 °F (38 °C)Operating ambient temperatureTypical for freezers: 50 to 109 °F (10 to 43 °C) | p. 6 |
| Sabbath mode | YesWhen diagnosing a unit that does not seem to power on | p. 37 |
Models in this manual
3 models with ENERGY STAR certified data. Models with the same figures share a row.
| Models | Type | Capacity | Energy use | Ice | Height × width |
|---|---|---|---|---|---|
| UHFZ124-IS01B, UHFZ124-SS01B, UOFZ124-SS01B | Compact | 4.8 ft³136 L | 390 kWh/yr11% below US standard40% more than the median of 66 similar certified models (278 kWh/yr) | None |
U-Line FZ124 questions
Answers taken from this manual. Each one links to the page it comes from.
How do I check the freezer’s actual temperature?
Use a water-filled bottle and thermometer, then adjust the control only after the 24-hour test.
- Partially fill a plastic, nonbreakable bottle with water.
- Insert an accurate thermometer and tighten the bottle cap securely.
- Place the bottle in the desired area for 24 hours.
- Avoid opening the freezer during the testing period.
- After 24 hours, check the water temperature.
- If needed, adjust the temperature control in a small increment.
Manual: page 29
The freezer is not cold enough. What should I check?
Adjust the set point only after checking the product temperature and these conditions.
- Temperature is too warm. Adjust the temperature to a cooler set point.
- The door is not sealing. Check that the door closes and seals properly.
- Airflow is blocked. Clear the front grille at the bottom of the unit.
- The condenser coil is dirty. Clean the coil and remove dirt or lint buildup.
- The unit is too warm or sunlit. Move it away from excessive ambient temperatures or direct sunlight.
Manual: page 28
Why is frost or condensation appearing on my freezer?
- Improper door seal. Check that the door closes and seals correctly.
- High humidity. Moisture on the outside should fade as humidity decreases.
Manual: page 28
What should I check first if the freezer does not seem to power on?
First, verify that the unit is not set to sabbath mode, then begin the power-fault checks.
Manual: page 37
What clearance does a built-in U-Line freezer need?
None at the top, sides, or rear, but do not block the front grille and leave room for the rear electrical connection.
Manual: page 8
How much space should separate side-by-side units?
Leave 1/4" (6 mm) between units to provide unobstructed door swing.
Manual: page 9
What happens when I view the error log?
The errors scroll once in occurrence order and stay stored in memory; only a door error appears on the display and sounds an alert.
Manual: page 40
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| E0 | Upper door 1 is open. | p. 40 | |
| E1 | Thermistor 1 is open. | p. 40 | |
| E2 | Thermistor 2 is open. | p. 40 | |
| E3 | Thermistor 3 is open. | p. 40 | |
| E4 | Thermistor 4 is open; unavailable on this model. | p. 40 | |
| E5 | Thermistor 1 is shorted. | p. 40 | |
| E6 | Thermistor 2 is shorted. | p. 40 | |
| E7 | Thermistor 3 is shorted. | p. 40 | |
| E8 | Thermistor 4 is shorted; unavailable on this model. | p. 40 | |
| E9 | Lower door 2 is open. | p. 40 | |
| P1 | Pump circuit is open; unavailable on this model. | p. 40 |
U-Line FZ124 compared with other brands
Freezers from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| U-Line FZ124 | Danby DUFM060B1WDB | |
|---|---|---|
| Space to open the doors | 1/4" (6 mm) | enough space on at least 2 sides |
| Room temperature range | 50 °F (10 °C) and 100 °F (38 °C) | 0 °F to 110 °F (-17 °C to 43 °C) |
Similar compact models from other brands
Same layout, capacity within 1.5 ft³ (42 L) of this one. Figures: ENERGY STAR.
| Model | Capacity | Energy use | Ice | Counter depth |
|---|---|---|---|---|
| Master Chef 043-0293-0 | 5 ft³142 L | 196 kWh/yr | None | No |
| L2 LRC05M2AWWC | 5 ft³142 L | 196 kWh/yr | None | No |
| Danby DUFM043A2 | 4.3 ft³122 L | 260 kWh/yr | None | No |
| Koolmore KM-RUF-42C | 4.2 ft³119 L | 260 kWh/yr | None | No |
| LG LROFC0605 | 5.8 ft³164 L | 283 kWh/yr | None | No |
| Criterion CUF36C1W | 3.6 ft³102 L | 252 kWh/yr | None | No |
Similar U-Line freezers
| U-Line UHFZ124-SS01BCompact, 4.8 ft³ | User Manual | 48 pages |
|---|---|---|
| U-Line UHFZ124-IS01BCompact, 4.8 ft³ | User Manual | 51 pages |
| U-Line UOFZ124-SS01BCompact, 4.8 ft³ | User Manual | 47 pages |