Have a question about the U-Line UOFZ124-SS01B? The AI assistant looks through this manual and shows the pages with the answer.
Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all freezer manuals on this site that print the same figure.
| Clearance above | no additional air spaceBuilt-in installationTypical for freezers: 3 to 5.5 in (7.6 to 14 cm) | p. 7 |
|---|---|---|
| Clearance at the sides | no additional air spaceBuilt-in installationTypical for freezers: 3 to 5 in (7.6 to 12.7 cm) | p. 7 |
| Clearance behind | no additional air spaceBuilt-in installation; electrical connection clearance is still required at the rearTypical for freezers: 2 to 5 in (5.1 to 12.7 cm) | p. 7 |
| Space to open the doors | 1/4" (6 mm)Between side-by-side units | p. 8 |
| Defrost | automaticunit | p. 24 |
| Room temperature range | 50 °F (10 °C) and 100 °F (38 °C)Operating environmentTypical for freezers: 50 to 109 °F (10 to 43 °C) | p. 5 |
Models in this manual
1 model with ENERGY STAR certified data. Models with the same figures share a row.
| Models | Type | Capacity | Energy use | Ice | Height × width |
|---|---|---|---|---|---|
| UOFZ124-SS01B | Compact | 4.8 ft³136 L | 390 kWh/yr11% below US standard40% more than the median of 66 similar certified models (278 kWh/yr) | None |
U-Line UOFZ124-SS01B questions
Answers taken from this manual. Each one links to the page it comes from.
Why is my freezer not cold enough?
- Warm temperature setting. Select a colder setting.
- Heat or sunlight nearby. Check the installation area for excessive ambient heat or direct sunlight.
- Door not sealing. Check that the door closes and seals properly.
- Interior light stays on. Check that the light has not remained on too long.
- Restricted airflow or dirty condenser. Clear the lower grille and remove dirt or lint from the condenser.
Manual: page 24
How do I check the freezer's actual temperature?
Use a water-filled bottle and thermometer to measure the freezer's actual temperature.
- Partially fill a plastic, nonbreakable bottle with water.
- Put an accurate thermometer inside the bottle.
- Tighten the bottle cap securely.
- Place the bottle in the area you want to test for 24 hours.
- Do not open the freezer during the test.
- After 24 hours, check the water temperature and adjust the control slightly if needed.
Manual: page 25
Why is frost forming on the freezer's internal surfaces?
A door that does not close or seal properly can cause internal frost; check that the door closes and seals properly.
Manual: page 24
Why is condensation appearing on the freezer's exterior?
Excess humidity causes external condensation; moisture dissipates as humidity levels decrease.
Manual: page 24
What clearance does the freezer need for built-in installation?
No additional air space is needed at the top, sides, front, or rear for built-in installation. Do not block the front grille, and leave rear clearance for the electrical connection.
Manual: page 7
How much space is needed between side-by-side units?
1/4" (6 mm) of space must remain between side-by-side units for unobstructed door swing.
Manual: page 8
What do the freezer’s error codes mean?
These codes indicate the following conditions for this model.
| Code | Meaning |
|---|---|
| E0 | Upper door open |
| E1, E2, E3 | Thermistor 1, 2, 3 open |
| E5, E6, E7 | Thermistor 1, 2, 3 shorted |
| E9 | Lower door open |
| E4, E8, P1 | Do not apply to this model |
Manual: page 40
What happens when I view the error log?
The error list scrolls once in occurrence order, remains stored in memory, and only door errors appear on the display with an audible signal.
Manual: page 40
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| E0 | Upper door is open. | p. 40 | |
| E1 | Thermistor 1 is open. | p. 40 | |
| E2 | Thermistor 2 is open. | p. 40 | |
| E3 | Thermistor 3 is open. | p. 40 | |
| E4 | Thermistor 4 is open; this does not apply to this model. | p. 40 | |
| E5 | Thermistor 1 is shorted. | p. 40 | |
| E6 | Thermistor 2 is shorted. | p. 40 | |
| E7 | Thermistor 3 is shorted. | p. 40 | |
| E8 | Thermistor 4 is shorted; this does not apply to this model. | p. 40 | |
| E9 | Lower door is open. | p. 40 | |
| P1 | Pump circuit is open; this does not apply to this model. | p. 40 |
U-Line UOFZ124-SS01B compared with other brands
Freezers from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| U-Line UOFZ124-SS01B | Danby DUFM060B1WDB | |
|---|---|---|
| Space to open the doors | 1/4" (6 mm) | enough space on at least 2 sides |
| Room temperature range | 50 °F (10 °C) and 100 °F (38 °C) | 0 °F to 110 °F (-17 °C to 43 °C) |
Similar compact models from other brands
Same layout, capacity within 1.5 ft³ (42 L) of this one. Figures: ENERGY STAR.
| Model | Capacity | Energy use | Ice | Counter depth |
|---|---|---|---|---|
| Master Chef 043-0293-0 | 5 ft³142 L | 196 kWh/yr | None | No |
| L2 LRC05M2AWWC | 5 ft³142 L | 196 kWh/yr | None | No |
| Danby DUFM043A2 | 4.3 ft³122 L | 260 kWh/yr | None | No |
| Koolmore KM-RUF-42C | 4.2 ft³119 L | 260 kWh/yr | None | No |
| LG LROFC0605 | 5.8 ft³164 L | 283 kWh/yr | None | No |
| Criterion CUF36C1W | 3.6 ft³102 L | 252 kWh/yr | None | No |
Similar U-Line freezers
| U-Line UHFZ124-SS01BCompact, 4.8 ft³ | User Manual | 48 pages |
|---|---|---|
| U-Line UHFZ124-IS01BCompact, 4.8 ft³ | User Manual | 51 pages |
| U-Line FZ124Compact, 4.8 ft³ | User Manual | 47 pages |