Have a question about the U-Line UHFZ124-SS01B? The AI assistant looks through this manual and shows the pages with the answer.
Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all freezer manuals on this site that print the same figure.
| Door-open alarm after | 5 minutesWhen the door remains open longer than thisTypical for freezers: 3 to 5 minutes | p. 38 |
|---|---|---|
| Clearance above | does not require additional air spaceBuilt-in installationno additional air spacebuilt-in installationTypical for freezers: 3 to 5.5 in (7.6 to 14 cm) | p. 8 |
| Clearance at the sides | does not require additional air spaceBuilt-in installationno additional air spacebuilt-in installationTypical for freezers: 3 to 5 in (7.6 to 12.7 cm) | p. 8 |
| Clearance behind | does not require additional air spaceBuilt-in installationno additional air spacebuilt-in installationTypical for freezers: 2 to 5 in (5.1 to 12.7 cm) | p. 8 |
| Space to open the doors | 1/4" (6 mm)side-by-side installation, between units | p. 9 |
| Defrost | automaticduring the defrost cycle | p. 25 |
| Room temperature range | 50 °F (10 °C) and 100 °F (38 °C)Operating ambient temperatureTypical for freezers: 50 to 109 °F (10 to 43 °C) | p. 6 |
| Sabbath mode | YesUHFZ124-SS01B | p. 38 |
Models in this manual
1 model with ENERGY STAR certified data. Models with the same figures share a row.
| Models | Type | Capacity | Energy use | Ice | Height × width |
|---|---|---|---|---|---|
| UHFZ124-SS01B | Compact | 4.8 ft³136 L | 390 kWh/yr11% below US standard40% more than the median of 66 similar certified models (278 kWh/yr) | None |
U-Line UHFZ124-SS01B questions
Answers taken from this manual. Each one links to the page it comes from.
How do I check the freezer’s actual temperature?
Test the water temperature after the bottle has remained inside for 24 hours.
- Partly fill a nonbreakable plastic bottle with water.
- Put an accurate thermometer inside the bottle.
- Securely tighten the bottle cap.
- Set the bottle in the area you want to check for 24 hours.
- Do not open the freezer during the test.
- After 24 hours, read the water temperature.
- If needed, adjust the temperature control by a small increment.
Manual: page 26
Why is frost forming on the freezer’s internal surfaces?
A door that does not close or seal properly can cause internal frost; check the door seal.
Manual: page 25
Why is condensation forming on the outside of the freezer?
High humidity causes external condensation; the moisture should clear as humidity decreases.
Manual: page 25
Why is my freezer not cooling?
Check condenser airflow and cleanliness, then confirm condenser fan operation.
Manual: page 37
The freezer is not running; what should I check first?
Check that Sabbath mode is not enabled before diagnosing a power-on problem.
Manual: page 38
What clearance does built-in installation need around the freezer?
No extra space is needed above, beside, or behind the unit, but keep the front grille clear and allow room for the rear electrical connection.
Manual: page 8
How much space should separate side-by-side units?
1/4" (6 mm) must remain between the units for unobstructed door swing.
Manual: page 9
What do the error codes mean?
They identify door, thermistor, and pump-circuit faults.
| Code | Meaning | Model note |
|---|---|---|
| E0 | Door 1, upper, open | |
| E9 | Door 2, lower, open | |
| E1, E2, E3, E4 | Thermistors 1 to 4 open | E4 does not apply |
| E5, E6, E7, E8 | Thermistors 1 to 4 shorted | E8 does not apply |
| P1 | Pump circuit open | Does not apply |
Manual: page 41
How does VIEW ERROR LOG display recorded errors?
The entries scroll once in the order they occurred, while all errors remain stored in memory.
Manual: page 41
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| E0 | Upper door is open. | p. 41 | |
| E1 | Thermistor 1 is open. | p. 41 | |
| E2 | Thermistor 2 is open. | p. 41 | |
| E3 | Thermistor 3 is open. | p. 41 | |
| E4 | Thermistor 4 is open. | p. 41 | |
| E5 | Thermistor 1 is shorted. | p. 41 | |
| E6 | Thermistor 2 is shorted. | p. 41 | |
| E7 | Thermistor 3 is shorted. | p. 41 | |
| E8 | Thermistor 4 is shorted. | p. 41 | |
| E9 | Lower door is open. | p. 41 | |
| P1 | Pump circuit is open. | p. 41 |
U-Line UHFZ124-SS01B compared with other brands
Freezers from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| U-Line UHFZ124-SS01B | Marvel MLFZ | Danby DUF140E1WDD | Summit ADFD2D24 | |
|---|---|---|---|---|
| Door-open alarm after | 5 minutes | more than 30 minutes | more than 5 minutes | more than 5 minutes |
| Space to open the doors | 1/4" (6 mm) | · | · | · |
| Room temperature range | 50 °F (10 °C) and 100 °F (38 °C) | 55 °F to 100 °F (13 °C to 38 °C) | 0 °F to 110 °F (-17 °C to 43 °C) | 50ºF and 100ºF (10º to 38ºC) |
Similar compact models from other brands
Same layout, capacity within 1.5 ft³ (42 L) of this one. Figures: ENERGY STAR.
| Model | Capacity | Energy use | Ice | Counter depth |
|---|---|---|---|---|
| Master Chef 043-0293-0 | 5 ft³142 L | 196 kWh/yr | None | No |
| L2 LRC05M2AWWC | 5 ft³142 L | 196 kWh/yr | None | No |
| Danby DUFM043A2 | 4.3 ft³122 L | 260 kWh/yr | None | No |
| Koolmore KM-RUF-42C | 4.2 ft³119 L | 260 kWh/yr | None | No |
| LG LROFC0605 | 5.8 ft³164 L | 283 kWh/yr | None | No |
| Criterion CUF36C1W | 3.6 ft³102 L | 252 kWh/yr | None | No |
Similar U-Line freezers
| U-Line UHFZ124-IS01BCompact, 4.8 ft³ | User Manual | 51 pages |
|---|---|---|
| U-Line FZ124Compact, 4.8 ft³ | User Manual | 47 pages |
| U-Line UOFZ124-SS01BCompact, 4.8 ft³ | User Manual | 47 pages |