Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Clearance at the sidesNoneat sidesTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 6
Clearance behind2 inches (5.1 cm)at backTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 6
DefrostautomaticDanfoss controllermanualElectronic Controllerp. 11 p. 13

Victory VPP questions

Answers taken from this manual. Each one links to the page it comes from.

Why does the refrigerator run almost constantly?
  • The condenser is dirty. Clean the condenser.
  • The evaporator is iced over. Defrost the evaporator.
  • The room is too warm. Lower the room temperature.
  • The temperature control is faulty or stuck open. Adjust or replace it.

Manual: page 23

The unit is not cooling and is silent. What should I check?
  • Power is disconnected. Connect the unit to the proper voltage circuit.
  • The fuse or breaker tripped. Replace the fuse or reset the breaker.
  • The power plug is loose. Check the outlet connection and replace it as needed.

Manual: page 23

How do I clean the door gaskets?
  1. Remove food and shelves, then store food at a safe temperature.
  2. Disconnect power by unplugging the unit or switching off the breaker.
  3. Remove loose food particles from the door liner and surrounding interior.
  4. Scrub the gaskets with a warm (100oF to 110oF) detergent solution and soft scrub brush.
  5. Rinse with clean water and let the gaskets and interior air dry.
  6. Return the shelves, restore power, and replace food after reaching a safe temperature.

Manual: page 20

How does defrosting work on my refrigerator?
  • Danfoss controller: Defrost occurs automatically as needed, with no fixed defrost schedule.
  • Electronic Controller: Defrost is manual, and its LED indicator does not operate.

Manual: page 11, page 13

How do I start a manual defrost?
  • Danfoss controller: Push and immediately release the melting or defrost button; holding it too long shuts the controller off.
  • Electronic Controller: Quickly press and release DEFROST (ESC) to activate manual defrost.

Manual: page 11, page 13

How do I restore power after cleaning the interior?

Disconnect power before cleaning, then restore it after the shelves are secured.

  1. Remove food and shelves; store the food at a safe temperature.
  2. Disconnect power by unplugging the unit or switching off the breaker.
  3. Clear loose food particles from the interior surfaces.
  4. Scrub surfaces and gaskets with warm (100oF to 110oF) detergent solution.
  5. Rinse with clean water and let the interior air dry.
  6. Replace and secure the shelves.
  7. Restore power to the unit.
  8. Return food after the unit reaches a safe temperature.

Manual: page 20

What does the alarm LED mean?

The alarm LED shows whether an alarm is present or has been silenced.

LED stateMeaning
On fixedALARM present
FlashingALARM silenced
OffNo alarm

Manual: page 13

Similar Victory commercial refrigeration

Victory VERSA-1D-GD-HCInstallation & Operation Manual53 pages
Victory VEFSA-1D-HD-HC-*Installation & Operation Manual48 pages
Victory VBCFT-20-202PU-HCOperating Instructions42 pages
Victory VWR36HC*********Installation & Operation Manual31 pages
Victory VUR36HC*********Installation & Operation Manual30 pages
Victory VWF*48HC*********Installation & Operation Manual26 pages
Victory VUF*48HC*********Installation & Operation Manual25 pages
Victory Commercial Refrigeration Operating InstructionsOperating Instructions38 pages
All Victory commercial refrigeration →