Allavino error codes
11 Allavino error and alarm codes from 12 manuals: what each code means and what the manual says to do.
11 codes12 manuals
Codes and what they mean
As described in each manual. The same code can mean different things on different models, so check the model column.
| Code | Meaning | What to do | Manual |
|---|---|---|---|
| C1 | Upper zone temperature sensor has an open circuit. | VSW2734D-2, VSW3015S-1, VSW71LD-2, VSW15471D-2 | |
| C1 | Temperature sensor open circuit. | VSW3634FD-2S | |
| C1 | Temperature sensor has an open circuit. | VSW16371S-1 | |
| C1 | Wine cellar does not operate. | Check the power connection, circuit breaker, fuse, and temperature setting. | VSW15471D-2 |
| C2 | Lower zone temperature sensor has an open circuit. | VSW2734D-2, VSW3015S-1, VSW71LD-2, VSW15471D-2 | |
| C2 | Upper zone temperature sensor has a short circuit. | VSW15471D-2 | |
| DO | Door has remained open for three minutes. | Press any control button to silence it, or let it stop automatically after five minutes. | VSW2734D-2, VSW16371S-1 |
| DO | Door has been open for three minutes and alarm sounds. | VSW3634FD-2S | |
| DO | The door has remained open for three minutes. | Press any control panel button to silence the alarm. | VSW3015S-1, VSW71LD-2, VSW15471D-2, VSW5134D-2 |
| DO | Door has remained open for up to three minutes. | Press any control button to silence the alarm, or wait five minutes. | VSW16371S-1 |
| DO | Door has been open for three minutes. | VSW15471D-2 | |
| DO | The door has been open for three minutes. | VSW6771S-1 | |
| E1 | Upper sensor has a short circuit. | Contact warranty support or an authorized technician. | YHWR172-2, YHWR99-2 |
| E2 | Upper sensor has an open circuit. | Contact warranty support or an authorized technician. | YHWR172-2, YHWR99-2 |
| E3 | Lower sensor has a short circuit. | Contact warranty support or an authorized technician. | YHWR172-2, YHWR99-2 |
| E4 | Lower sensor has a short circuit. | Contact warranty support or an authorized technician. | YHWR172-2, YHWR99-2 |
| HH | High temperature alarm. | VSW2734D-2, VSW3634FD-2S, VSW3015S-1, VSW71LD-2 | |
| HH | The appliance temperature is too high. | VSW15471D-2 | |
| LL | Low temperature alarm. | VSW2734D-2, VSW3634FD-2S, VSW3015S-1, VSW71LD-2 | |
| LL | The appliance temperature is too low. | VSW15471D-2 | |
| U1 | Upper zone temperature sensor has a short circuit. | VSW2734D-2, VSW3015S-1, VSW71LD-2, VSW15471D-2 | |
| U1 | Temperature sensor short circuit. | VSW3634FD-2S | |
| U1 | Temperature sensor has a short circuit. | VSW16371S-1 | |
| U1 | Upper zone temperature sensor has an open circuit. | VSW15471D-2 | |
| U2 | Lower zone temperature sensor has a short circuit. | VSW2734D-2, VSW3015S-1, VSW71LD-2, VSW15471D-2 | |
| U2 | Lower zone temperature sensor has an open circuit. | VSW15471D-2 |