Same manual for other models

These manuals share their text with this one.

Arctic Air Commercial RefrigeratorCommercial RefrigeratorSame manualInstallation & Operation Manual · 27 pages

Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Fridge adjustment range34 °F to 38 °F (1 °C, 3 °C)All food prep units, under-counter refrigerators, and worktop refrigeratorsTypical for commercial refrigeration: 34 to 45 °F (1 to 7 °C)p. 8
Freezer adjustment range-3 °F to -7 °F (-19 °C, -22 °C)Under-counter and worktop freezersTypical for commercial refrigeration: -8 to 3 °F (-22 to -16 °C)p. 8
Wait before use24 hoursIf the unit is laid on its side or back before start-upp. 7

Arctic Air Commercial Refrigerator questions

Answers taken from this manual. Each one links to the page it comes from.

How much space should I leave around the commercial unit?

Leave at least two inches from a wall, with clear air intake and exhaust paths.

Manual: page 7

How long should the unit stand upright before startup?

After being laid on its side or back, leave the unit upright for a minimum of 24 hours before startup.

Manual: page 7

What should I do if the equipment arrives damaged?
  1. Inspect the package, skid, and container before unpacking.
  2. If damage is visible, open the package with the carrier and inspect the contents.
  3. Report hidden damage to the carrier both verbally and in writing.
  4. Request damage forms and a shipping-company inspection within 10 days of receipt.
  5. Keep all crating until the inspection is completed or waived.

Manual: page 6

Where can I find the unit’s serial number?

Inside the unit, on the left wall near the top; have it ready when requesting parts or service.

Manual: page 6

What do the Fan, Compressor, and Alarm indicators mean?

These indicators show operating conditions and temperature alarms.

IndicatorMeaning
FanFans are running.
CompressorCompressor is running.
AlarmA temperature alarm occurred.

Manual: page 8

How do I clean the condenser coil?

Turn off the unit and disconnect its power before cleaning the condenser coil.

  1. Clean the condenser coil at least every 90 days.
  2. Shorten cleaning to every 30 days if debris, dust, or grease builds up sooner.
  3. Brush away light dust and debris.
  4. Use a vacuum or compressed air for heavier dust.
  5. Treat heavy grease with a coil degreaser, then blow through with compressed air.
  6. Do not use a high-pressure water wash near the condenser coil.

Manual: page 10

How do I replace the door gasket?
  1. Pull the old gasket from the door groove.
  2. Press the replacement gasket into the groove.

Manual: page 11

Why is water collecting inside or beneath the unit?
  • Loose drain tube. Reconnect it between the evaporator housing and condensate evaporator drain pan.
  • Tube out of the pan. Place the condensate evaporator drain tube inside the drain pan.
  • Unit not level or drain blocked. Level the unit and clear obstructions from drain lines.

Manual: page 11

Error codes in this manual

CodeMeaningWhat to do
CASerious external alarm when i1F equals bal.Display the alarm with both arrow buttons; hold SET to reset it.p. 9
CSdCondenser alarm.Display the alarm with both arrow buttons; hold SET to reset it.p. 9
dADoor open alarm.Display the alarm with both arrow buttons; hold SET to reset it.p. 9
EAExternal alarm.Display the alarm with both arrow buttons; hold SET to reset it.p. 9
HAMaximum temperature alarm.Display the alarm with both arrow buttons; hold SET to reset it.p. 9
LAMinimum temperature alarm.Display the alarm with both arrow buttons; hold SET to reset it.p. 9
P1Room temperature probe failure.Display the alarm with both arrow buttons; hold SET to reset it.p. 9
P2Evaporator probe failure.Display the alarm with both arrow buttons; hold SET to reset it.p. 9
P3Condenser probe failure.Display the alarm with both arrow buttons; hold SET to reset it.p. 9
All Arctic Air error codes →

Arctic Air Commercial Refrigerator compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Arctic Air Commercial RefrigeratorOther Commercial RefrigeratorPolar UA001Gram Commercial Refrigerator
Fridge adjustment range34 °F to 38 °F (1 °C, 3 °C)34 °F to 38 °F (1 °C, 3 °C)-2 °C to +4 °C (28 °F, 39 °F)2 to 12 °C (36 to 54 °F)
Freezer adjustment range-3 °F to -7 °F (-19 °C, -22 °C)-7°Fto -1 °F (-22 °C, -18 °C)-18 °C to -22 °C (0 °F, -8 °F)-10 to -22 °C (14 to -8 °F)
Wait before use24 hoursat least 24 hoursabout 12 hoursat least 2 hours