Arctic Air Commercial RefrigeratorCommercial RefrigeratorSame manualUser Manual · 21 pages

Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Fridge adjustment range34 °F to 38 °F (1 °C, 3 °C)Food prep units, under-counter and worktop refrigeratorsTypical for commercial refrigeration: 34 to 45 °F (1 to 7 °C)p. 10
Freezer adjustment range-3 °F to -7 °F (-19 °C, -22 °C)Under-counter and worktop freezersTypical for commercial refrigeration: -8 to 3 °F (-22 to -16 °C)p. 10
Wait before use24 hourswhen the unit is laid on its side or backp. 9
DefrostautomaticThe unit defrosts every 6 hoursp. 10

Arctic Air Commercial Refrigerator questions

Answers taken from this manual. Each one links to the page it comes from.

How do I clean the door gasket?

Use warm soapy water to clean the gasket.

  1. Avoid full-strength cleaning products, which can make the gasket brittle.
  2. Do not use sharp tools or knives on the gasket.

Manual: page 13

How often does the unit defrost, and how long can the cycle last?

Every 6 hours, the unit defrosts and restarts when the coil reaches terminal temperature or after 20 minutes.

Manual: page 10

How do I start a manual defrost cycle?

Hold Defrost for a minimum of two seconds to start the manual defrost cycle.

Manual: page 11

How do I level an under-counter refrigerator or freezer?

Use a level from front to back and side to side, then adjust based on the support type.

  • Legs: Adjust the bullet feet until the cabinet is level.
  • Casters: Level the floor because caster units have no leveling adjustment.
  • After positioning a caster unit, lock the front wheels to prevent movement.

Manual: page 9

How do I display and reset an alarm code?
  1. Press Up Arrow and Down Arrow together to display the alarm code.
  2. Hold SET until rst appears, then release it.
  3. Press SET again; rst blinks and the room temperature returns.

Manual: page 11

Error codes in this manual

CodeMeaningWhat to do
CASerious external alarm.Display the alarm with the arrow buttons, then reset it using SET.p. 11
CSdCondenser alarm.Display the alarm with the arrow buttons, then reset it using SET.p. 11
dADoor open.Display the alarm with the arrow buttons, then reset it using SET.p. 11
EAExternal alarm.Display the alarm with the arrow buttons, then reset it using SET.p. 11
HAMaximum temperature alarm.Display the alarm with the arrow buttons, then reset it using SET.p. 11
LAMinimum temperature alarm.Display the alarm with the arrow buttons, then reset it using SET.p. 11
P1Room temperature probe failure.Display the alarm with the arrow buttons, then reset it using SET.p. 11
P2Evaporator probe failure.Display the alarm with the arrow buttons, then reset it using SET.p. 11
P3Condenser probe failure.Display the alarm with the arrow buttons, then reset it using SET.p. 11
All Arctic Air error codes →

Arctic Air Commercial Refrigerator compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Arctic Air Commercial RefrigeratorOther Commercial RefrigeratorPolar UA001Gram Commercial Refrigerator
Fridge adjustment range34 °F to 38 °F (1 °C, 3 °C)34 °F to 38 °F (1 °C, 3 °C)-2 °C to +4 °C (28 °F, 39 °F)2 to 12 °C (36 to 54 °F)
Freezer adjustment range-3 °F to -7 °F (-19 °C, -22 °C)-7°Fto -1 °F (-22 °C, -18 °C)-18 °C to -22 °C (0 °F, -8 °F)-10 to -22 °C (14 to -8 °F)
Wait before use24 hoursat least 24 hoursabout 12 hoursat least 2 hours