How do I install the case pedestals, rails, panels, and bumper?
- Fasten the pedestals to each case wrap end with the supplied fasteners.
- Align the “J” rail with the basehorses and secure it with the supplied screws.
- Slide the kickplate into the “J” rail.
- Stand the lower front panel upright and fit it into the retainer.
- Leave the nose bumper in the store for 24 hours, then insert its bottom first.
- Roll the nose bumper through the master bumper channel without stretching it.
Manual: page 15
How do I access the case drain area?
Access the drain area from the front of the case.
- Lift and remove the lower front panel.
- If installed, lift and remove the kickplate.
- Reach the drain outlet at the front center of either case side.
Manual: page 17
What drain connection does the case use?
The case uses a 1 1/2" PVC drain connection.
Manual: page 9
What shelf sizes are available?
Available shelf sizes are 12" and 16".
Manual: page 9
How do I clean a Hill Phoenix case safely?
- Switch off every electrical supply before cleaning.
- Do not spray water or cleaner onto fan motors or electrical connections.
- Dry all lighting receptacles before insertion and restoring the lighting circuit.
Manual: page 32
How do I order a replacement part for this case?
- Contact the Service Parts Department at 800-283-1109.
- Provide the case model number and serial number.
- Give the part length, such as 8’ or 12’, if applicable.
- Give the painted or polymer part color.
- State whether shelves have lights, and provide the quantity.
- For a credit return, request a Return Materials Authorization Number.
Manual: page 30
How long does the Hill Phoenix warranty last?
Fourteen months from original shipment covers material or workmanship defects during normal use and maintenance. A replacement part may be provided without charge when the defective part is returned, but labor and other repair costs are excluded.
Manual: page 31
Similar Hill Phoenix commercial refrigeration
| Hill Phoenix P056170DModel family P05 | Installation & Operation Manual | 36 pages |
|---|---|---|
| Hill Phoenix PF-54-SC | Installation & Operation Manual | 33 pages |
| Hill Phoenix Commercial Refrigeration Installation & Operation Manual | Installation & Operation Manual | 54 pages |
| Hill Phoenix Commercial Refrigeration Installation & Operation Manual | Installation & Operation Manual | 52 pages |
| Hill Phoenix Commercial Refrigeration Installation & Operation Manual | Installation & Operation Manual | 44 pages |
| Hill Phoenix Commercial Refrigeration Installation & Operation Manual | Installation & Operation Manual | 44 pages |
| Hill Phoenix Commercial Refrigeration Installation & Operation Manual | Installation & Operation Manual | 40 pages |
| Hill Phoenix Commercial Refrigeration Installation & Operation Manual | Installation & Operation Manual | 36 pages |