Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Door-open alarm after | 0÷99 min later than mostXR03CX, when iF=doTypical for commercial refrigeration: 1 to 5 minutes | p. 31 |
|---|
Hill Phoenix Commercial Refrigerator questions
Answers taken from this manual. Each one links to the page it comes from.
How do I adjust the case temperature settings?
- Hold UP or DOWN for 2-3 seconds, changing one setting number at a time.
- Wait 1-2 hours for the case temperature to stabilize before another adjustment.
- Judge the setting by measuring product interior temperature, not case air temperature.
- Turn the case on 1 hour before placing product.
Manual: page 22
What heat settings should I use as starting points?
Begin with these settings, then adapt them to the product and store conditions.
| Heat setting | Application |
|---|---|
| 5-6 heat-setting | Overhead Controls |
| 5-6 heat-setting | Fried Foods |
| 2-5 heat-setting | Immersed Foods |
Manual: page 22
What store conditions does the display case require?
An air-conditioned store with a maximum ambient of 75 °F and 55% relative humidity is required.
Manual: page 12
How do I position multiple cases before joining them?
For a multi-case lineup, position and join the cases in this order.
- Position the next case approximately 3’ away from the first case.
- Move it to approximately 6" from the first case and place it on the shim packs.
- Push the cases tightly together.
- Lightly bolt them through the provided holes.
- Tighten joining bolts until all margins are equal, without overtightening.
Manual: page 13
How do I turn the case lights on?
After an electrician connects the lighting circuit, use the ON/OFF switch in the raceway, power box, or inside back of the case.
Manual: page 16
Can I silence the alarm buzzer?
Yes, on XR03CX when tb is set to y, press a key during an alarm; the alarm relay switches off.
Manual: page 31
What do the controller's alarm messages mean?
The display message identifies the alarm condition.
| Message | Meaning |
|---|---|
| P1, P2 | Room or evaporator probe failure |
| HA, LA | Maximum or minimum temperature alarm |
| EA, CA | External or serious external alarm |
| dA | Door Open |
Manual: page 31
What does Er mean during Hot Key programming?
Er means programming failed; remove the Hot Key to abort.
Manual: page 31
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| AL | Minimum temperature alarm. | p. 32 | |
| AU | Maximum temperature alarm. | p. 32 | |
| dF | Display during defrost. | p. 32 |
Similar Hill Phoenix commercial refrigeration
| Hill Phoenix Commercial Refrigeration Installation & Operation Manual | Installation & Operation Manual | 54 pages |
|---|---|---|
| Hill Phoenix Commercial Refrigeration Installation & Operation Manual | Installation & Operation Manual | 52 pages |
| Hill Phoenix Commercial Refrigeration Installation & Operation Manual | Installation & Operation Manual | 44 pages |
| Hill Phoenix Commercial Refrigeration Installation & Operation Manual | Installation & Operation Manual | 44 pages |
| Hill Phoenix Commercial Refrigeration Installation & Operation Manual | Installation & Operation Manual | 40 pages |
| Hill Phoenix P056170D | Installation & Operation Manual | 36 pages |
| Hill Phoenix PF-54-SC | Installation & Operation Manual | 33 pages |
| Hill Phoenix P054955M | Installation & Operation Manual | 32 pages |