Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Clearance behind2”single case, between the wall and case backTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 7
Defrostelectric, hot gas, or timed-offHill PHOENIX casesp. 14
Room temperature range65 °F in winter and a maximum of 95 °F in summer (18 °C, 35 °C)air-cooled condensing unit machine roomsTypical for commercial refrigeration: 60 to 100 °F (16 to 38 °C)p. 6

Hill Phoenix Commercial Refrigerator questions

Answers taken from this manual. Each one links to the page it comes from.

How do I prevent product loading from causing temperature problems?

Keep products 1” to 2” below each shelf and within the load limit line. Do not cover discharge or return air sections.

Manual: page 14

What defrost methods can this case use?

Electric, hot gas, or timed-off defrost may be used; timed-off defrost switches refrigeration off for a specified time.

Manual: page 14

How much space should I leave behind a single case?

At least 2” must remain between the wall and the back of the case.

Manual: page 7

How do I level a single case after positioning it?

Use a bubble level to check both vertical plumb and horizontal level.

  1. Keep hands and feet out of the way before lowering the case.
  2. Raise one case end under the cross support with a “J” bar.
  3. Remove the caster assembly and lower the basehorse onto the shim packs.
  4. Repeat the caster removal and lowering process at the other end.
  5. Check vertical plumb with a bubble level on the rear wall; adjust shim packs.
  6. Check horizontal level with the bubble level on the front sill; adjust shim packs.

Manual: page 7

What should I check before powering up a Hill Phoenix case?
  1. Inspect the case for shipping damage and remove the casters.
  2. Check that the case is vertically plumb and horizontally level.
  3. Seal adjoining cases with foam tape gasket and sealant.
  4. Seal case joints at the pipe-chase seam with caulk and acrylic tape.
  5. Remove shipping blocks from the refrigeration lines.
  6. Seal any tank penetrations.
  7. Clear loose packaging and other case materials.

Manual: page 11

How do I remove the kickplate to reach the drain line?

Remove the screws, then pull the kickplate away from the case to expose the drain-line area.

Manual: page 10

Similar Hill Phoenix commercial refrigeration

Hill Phoenix Commercial Refrigeration Installation & Operation ManualInstallation & Operation Manual52 pages
Hill Phoenix Commercial Refrigeration Installation & Operation ManualInstallation & Operation Manual44 pages
Hill Phoenix Commercial Refrigeration Installation & Operation ManualInstallation & Operation Manual44 pages
Hill Phoenix Commercial Refrigeration Installation & Operation ManualInstallation & Operation Manual40 pages
Hill Phoenix Commercial Refrigeration Installation & Operation ManualInstallation & Operation Manual36 pages
Hill Phoenix P056170DInstallation & Operation Manual36 pages
Hill Phoenix PF-54-SCInstallation & Operation Manual33 pages
Hill Phoenix Commercial Refrigeration Installation & Operation ManualInstallation & Operation Manual32 pages
All Hill Phoenix commercial refrigeration →