Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Wait before use | at least twelve hoursafter transporting and installing the cooler, before connecting it | p. 16 |
|---|---|---|
| Time to cool down | at least one hourafter the cooler has been turned off, before introducing product14 hourscooler recovering temperature after its inside temperature is too highTypical for commercial refrigeration: 1 to 24 hours | p. 17 p. 26 |
| Defrost | automatic evaporator deicing systemcoolermanual | p. 23 |
Imbera VFS24 questions
Answers taken from this manual. Each one links to the page it comes from.
Do I need to adjust the cooler’s temperature control?
No. The electronic controls are set by the manufacturer, so routine temperature adjustments are not needed.
Manual: page 17
What should I do if the temperature control or alarm malfunctions?
Contact the Customer Service Center and do not adjust the control. This applies to CIF, EMS, LAE, ERC, and ETC1H issues.
Manual: page 18
Why will the cooler not turn on after a power interruption or restart?
- Power supply failure. Wait until electricity service is restored.
- The plug is loose. Connect the plug correctly to the outlet.
- The fuse burned or circuit breaker tripped. Replace the fuse or reset the circuit breaker.
- The cooler was just connected. Wait at least 5 minutes for the compressor to start running.
Manual: page 24
Why is the cooler still warm after I reconnect it?
- The cooler was connected recently. Wait a minimum of 14 hours for its temperature to recover.
- The condenser coil is dirty. Clean dust, lint, and waste from the coil.
- The evaporator coil is blocked by frost. Turn the cooler off to defrost it.
- Doors stay open too long or do not close. Keep doors from remaining open for prolonged periods.
- Airflow is poor or obstructed. Arrange products for airflow and stay below the max fill height.
Other brands: Other 5-6 hours · True 24 hours · Fisher & Paykel 2 to 3 hours Compare all
Manual: page 26
What should I do if the cooler shows a failure alarm?
Call the Customer Service Center. Do not adjust CIF, EMS, LAE, or ERC controls when failure alarms appear.
Manual: page 18
How do I turn the cooler lights off manually?
Use the lighting switch, if fitted, only while the business is closed; turn lighting on during sale hours.
Manual: page 20
Why do the lights turn off automatically?
The lights turn off automatically in savings mode on coolers with Intelligent Control Function (CIF); open the door to exit.
Manual: page 20