Why is the refrigerator temperature too high?

Adjust the thermostat. A room thermostat set too high can cause the temperature to be too high.

Manual: page 16

Why isn't the compressor running?
  • Main switch open. Close the switch.
  • Unit in defrost cycle. Wait for the cycle to finish.
  • Thermal overload tripped. Wait for automatic reset, then check the unit when it comes back online.

Manual: page 16, page 17

How much space should remain around the unit cooler during installation?

Leave 12” clearance from the bottom of the unit and enough space above for hand cleaning without tools.

Manual: page 5

Where should I locate the unit cooler?
  • Keep it away from doors and door openings.
  • For multiple units, avoid positioning them directly opposite each other.
  • Cover the room with the airflow pattern without restricting inlet or outlet air.

Manual: page 4, page 5

How do I set the 8145-20B defrost timer?
  1. Choose the daily defrost count and timing based on observed system operation.
  2. Insert the timer pins for the selected schedule.
  3. Set fail-safe termination a few minutes beyond the expected completion time.
  4. Use 30 to 50 minutes for air defrost or 25 to 40 minutes for electric defrost.

Manual: page 10, page 12

How many defrost cycles should I schedule each day?

Two to four defrost cycles per day are usually adequate for most applications. Set the final schedule by observing system operation.

Manual: page 10

Similar Turbo Air commercial refrigeration

Turbo Air KUCTB2504Model family KUCTB250User Manual26 pages
Turbo Air KGR12-2Service Manual41 pages
Turbo Air TGF-49FService Manual128 pages
Turbo Air PRO-26-2FService Manual54 pages
Turbo Air TSF-23SDService Manual53 pages
Turbo Air M3F24-1Service Manual46 pages
Turbo Air TSF-23SDService Manual46 pages
Turbo Air TST-28SDService Manual34 pages
All Turbo Air commercial refrigeration →