Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Door-open alarm after5 minutesdoor left openTypical for commercial refrigeration: 1 to 5 minutesp. 39
Clearance aboveno additional air spacebuilt-in installationTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 8
Clearance at the sidesno additional air spacebuilt-in installationTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 8
Clearance behindno additional air spacebuilt-in installationTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 8
Defrostautomaticp. 26
Room temperature range50 °F (10 °C) to 100 °F (38 °C)Typical for commercial refrigeration: 60 to 100 °F (16 to 38 °C)p. 6
Sabbath modeYesunit controlp. 39

U-Line UCRE518-SG33A questions

Answers taken from this manual. Each one links to the page it comes from.

How do I check the refrigerator's actual product temperature?
  1. Partially fill a plastic, nonbreakable bottle with water.
  2. Put an accurate thermometer inside, then tighten the cap securely.
  3. Set the bottle in the area you want to check for 24 hours.
  4. Do not open the unit while testing.
  5. Read the water temperature after 24 hours.
  6. Adjust the control slightly if needed.

Manual: page 27

What should I check if the refrigerator is not cooling?

Inspect airflow through the condenser, check whether it is clean, and confirm that the condenser fan operates.

Manual: page 38

Why is the ice maker producing less ice?

Higher ambient temperatures can reduce ice production; this unit operates between 50 °F (10 °C) and 100 °F (38 °C).

Manual: page 6

What clearance does the unit need for built-in installation?

For built-in installation, no extra space is specified above, beside, or behind the unit. Leave the front grille open and provide rear electrical-connection clearance.

Manual: page 8

Can I install the unit behind a closed cabinet door?

No. The unit cannot be installed behind a closed cabinet door.

Manual: page 8

What do the U-Line error codes mean?
  • E0: Door 1 (upper) open; E9: Door 2 (lower) open.
  • E1: Thermistor 1 open; E2: Thermistor 2 open.
  • E3: Thermistor 3 open; E7: Thermistor 3 shorted.
  • E5: Thermistor 1 shorted; E6: Thermistor 2 shorted.
  • E4, E8, and P1 do not apply to this model.

Manual: page 41, page 42

Does the error log store every error?

Yes, all errors are stored in memory, but only a door error appears on the display and sounds an audible signal.

Manual: page 41

Error codes in this manual

CodeMeaningWhat to do
E0Upper door 1 is open.p. 41
E1Thermistor 1 is open.p. 41
E2Thermistor 2 is open.p. 41
E3Thermistor 3 is open.p. 41
E4Thermistor 4 is open.p. 41
E5Thermistor 1 is shorted.p. 41
E6Thermistor 2 is shorted.p. 41
E7Thermistor 3 is shorted.p. 41
E8Thermistor 4 is shorted.p. 41
E9Lower door 2 is open.p. 41
P1Pump circuit is open.p. 41
All U-Line error codes →

U-Line UCRE518-SG33A compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

U-Line UCRE518-SG33AOther 9301F-290Summit SPR627OSTrue TGO-27-POP01
Door-open alarm after5 minutes2 minutesmore than 60 seconds5 minutes
Room temperature range50 °F (10 °C) to 100 °F (38 °C)70-100 °F (-73 °C)44ºF and 90ºF (7ºC to 32ºC)60 °F (15.5 °C)

Similar U-Line commercial refrigeration

U-Line UCRE518-SS33AModel family UCRE518SUser Manual48 pages
U-Line UCRE515-SG33AModel family UCRE51User Manual48 pages
U-Line UCRE515-SS33AModel family UCRE51User Manual48 pages
U-Line UCRE524-SS33AModel family UCRE5User Manual48 pages
U-Line UCRE524-SG33AModel family UCRE5User Manual48 pages
U-Line UCRE552-SS61AModel family UCRE5User Manual37 pages
U-Line UCFZ527-SS31AModel family UCFZ5User Manual30 pages
U-Line UCWC518-SS33AUser Manual49 pages
All U-Line commercial refrigeration →