| Freezer adjustment range | -5 to 5 F degreesULT32 freezer modelTypical for commercial refrigeration: -8 to 3 °F (-22 to -16 °C) | p. 5 |
|---|---|---|
| Clearance above | no clearance requirementsTraulsen unitTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm) | p. 4 |
| Clearance at the sides | no clearance requirementsTraulsen unitTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm) | p. 4 |
| Clearance behind | no clearance requirements needs less space than mostTraulsen unitTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm) | p. 4 |
Traulsen Commercial Refrigerator questions
Answers taken from this manual. Each one links to the page it comes from.
How do I adjust the refrigerator temperature?
Turn the adjustment screw slightly; clockwise lowers temperature, while OFF interrupts only the compressor and condenser fan.
Manual: page 5
What temperature range can the ULT32 freezer use?
The ULT32 freezer adjusts from -5 to 5 F degrees.
Manual: page 5
What clearance does Traulsen require around the cabinet?
No clearance is required at the sides, rear, or top, but provide air supply underneath and use legs, casters, or a front ventilated utility base.
Manual: page 4
How do I replace a door or drawer gasket?
- Pull the old gasket out of the gasket retainer.
- Push the four corners of the new gasket straight into the retainer.
- Do not stretch the gasket, or it will not return to its original length.
- Starting at one edge’s center, push the gasket straight into the retainer.
- Work from the center toward each corner until that edge is attached.
- Repeat this process on the remaining edges until the gasket is fully installed.
Manual: page 8
Where can I find the model and serial number?
The name tag is in the right interior compartment on all standard models.
Manual: page 2
How do I contact Traulsen service?
Call 800-825-8220 from 7:30 am - 4:30 pm CST, Monday thru Friday, or visit www.traulsen.com.
Manual: page 1
Similar Traulsen commercial refrigeration
| Traulsen G10000 | Service Manual | 78 pages |
|---|---|---|
| Traulsen AHT126WPUT-FHG | Service Manual | 40 pages |
| Traulsen G13010 | Service Manual | 32 pages |
| Traulsen AHT126WPUT-FHG | Owner's Manual | 26 pages |
| Traulsen G10000 | Owner's Manual | 24 pages |
| Traulsen TU044HT | Owner's Manual | 24 pages |
| Traulsen G10000 | Owner's Manual | 20 pages |
| Traulsen CLBM-23F-FS | Owner's Manual | 20 pages |