Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Clearance above12”above the condensing unit, for air circulation and certain maintenanceTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 5
Clearance behindunrestricted air flowalternative to 12” overhead clearanceTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 5
Space to open the doors120°door stay-open feature90°minimum door opening for maximum clear door widthp. 3
Defrostautomaticfreezer modelsp. 5

Traulsen G10000 questions

Answers taken from this manual. Each one links to the page it comes from.

The food compartment is too warm. What should I check?
  • Poor door or gasket seal. Check that doors and gaskets seal correctly.
  • Warm food or prolonged door opening. Allow adequate recovery time.
  • Control set too high. Re-adjust the control.
  • Dirty condensing coil. Check that the condensing coil is clean.

Manual: page 19

How do I remove a stubborn odor spill?

Mix 1 TBSP baking soda with 1 pint water for stubborn odor spills.

Manual: page 7

What overhead or rear clearance does the refrigerator need?

At least 12” above the condensing unit is required, or the back must have unrestricted airflow; 12” also permits certain maintenance.

Manual: page 5

How much room should I allow for the doors and doorway?
  • Side wall: leave room for the door stay-open feature at 120°; self-closing works through 90°.
  • Door opening: allow the door to open at least 90° for maximum clear width.
  • Doorway under 35”: remove the door or hinges if needed to pass through.

Manual: page 3, page 4

How do I replace the door gasket?
  1. Pull the old gasket out by one corner.
  2. Bring the unit and replacement gasket to room temperature.
  3. Fit all four corners first with a rubber mallet or hammer and wood block.
  4. Tap gently from both ends toward the center until the gasket is fully seated.
  5. A gasket that looks too large can fit when installed this way.

Manual: page 6, page 7

Traulsen G10000 compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Traulsen G10000EdgeStar VBM101SSHoshizaki Commercial Refrigerator
Clearance above12”1/2”30 cm (11.8 in)
Space to open the doors120°2 1/4”120 cm (47.2 in)

Similar Traulsen commercial refrigeration

Traulsen G10000Model family G10000Service Manual78 pages
Traulsen G10000Model family G10000Owner's Manual24 pages
Traulsen G10000Model family G10000Service Manual20 pages
Traulsen G13010Model family G13010Service Manual32 pages
Traulsen AHT126WPUT-FHGService Manual40 pages
Traulsen AHT126WPUT-FHGOwner's Manual26 pages
Traulsen TU044HTOwner's Manual24 pages
Traulsen CLBM-23F-FSOwner's Manual20 pages
All Traulsen commercial refrigeration →