Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Door-open alarm after | 0...30 min later than mostConfigurable delay before the door-open alarm warningTypical for commercial refrigeration: 1 to 5 minutes | p. 12 |
|---|---|---|
| Defrost | off-cyclerefrigeratorsautomaticfreezers | p. 6 |
Traulsen CLBM-23F-FS questions
Answers taken from this manual. Each one links to the page it comes from.
Can the unit fit through a doorway narrower than 33.5”?
A doorway under 33.5” may require removing the doors, access panels, and/or hinges to move the unit through.
Manual: page 4
How do I replace the door gasket?
Pull out the old gasket, then fit the replacement while both pieces are at room temperature.
- Pull the existing gasket out by one corner.
- Bring the unit and replacement gasket to room temperature.
- Seat all four corners first using a rubber mallet or wood-blocked hammer.
- Work from both ends toward the center, gently tapping until fully seated.
Manual: page 7
How should I clean the door gasket?
Wipe the gasket with baking soda mixed with warm water and a soft cloth, following the metal grain.
Manual: page 7
What does dEF mean on the display?
It means defrost is running:
| Appliance | During defrost | Defrost ends when |
|---|---|---|
| Refrigerator | Compressor off, fans on | Coil reaches 44 °F |
| Freezer | Compressor and fans off initially | Coil reaches 44 °F |
Manual: page 6
How often does automatic defrost run?
The schedule depends on the appliance:
| Appliance | Schedule | Maximum duration |
|---|---|---|
| Refrigerator | Every 6 hours | 30 minutes |
| Freezer | Approximately every 5 hours | Not specified |
Manual: page 6
What does HC mean when the refrigerator beeps?
It signals a high condenser alarm; HC flashes on the display and the buzzer sounds.
Manual: page 13
How long can the door stay open before the alarm warning?
The door-open alarm warning delay is adjustable from 0...30 min.
Manual: page 12
How do the interior lights operate?
They operate automatically or remain illuminated, depending on the model.
- Door-switch models: Opening the door turns the interior light on; closing it turns the light off.
- Other models: The interior lights stay illuminated with the doors open or closed.
Manual: page 6
Similar Traulsen commercial refrigeration
| Traulsen G10000 | Service Manual | 78 pages |
|---|---|---|
| Traulsen AHT126WPUT-FHG | Service Manual | 40 pages |
| Traulsen G13010 | Service Manual | 32 pages |
| Traulsen AHT126WPUT-FHG | Owner's Manual | 26 pages |
| Traulsen G10000 | Owner's Manual | 24 pages |
| Traulsen TU044HT | Owner's Manual | 24 pages |
| Traulsen G10000 | Owner's Manual | 20 pages |
| Traulsen G10000 | Service Manual | 20 pages |