Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Wait before use | 24 HOURSBefore plugging the cabinet into the power source | p. 6 |
|---|
True TFM-29FL questions
Answers taken from this manual. Each one links to the page it comes from.
How do I level a castored unit on an uneven floor?
- Rotate the bearing race counter-clockwise until the cabinet is level front to back and side to side.
- Fit the needed shims between the rail end and bearing race, with each slot around the castor stem.
- With multiple shims, turn each slot 90° so the slots do not align.
- Turn the bearing race clockwise, then tighten the anchoring bolt using a 3/4 inch open-end wrench or supplied tool.
Manual: page 7
How long should the cabinet stand upright before I plug it in?
Leave the cabinet upright for 24 hours before plugging it into power.
Manual: page 6
What should I connect the cabinet drain to during cleaning?
Route the cabinet drain hose through a hose leading to a floor drain during cleaning.
Manual: page 6
How do I clean the condenser safely?
- Disconnect electrical power from the unit.
- Remove the louvered grill.
- Vacuum or brush dirt, lint, and debris from the finned condenser coil.
- For heavy buildup, use compressed air with eye protection.
- Do not place filter material in front of the condenser coil, because it blocks airflow.
- Replace the louvered grill to protect the condenser.
- Reconnect electrical power. If dirt remains, call a refrigeration service company.
Manual: page 15
How often should I clean the condenser?
Every 30 days, or as needed.
Manual: page 15
How do I adjust a Danfoss temperature control for high altitude?
For high-elevation installations, adjust the control only after disconnecting the cooler from power.
- Disconnect power from the cooler.
- Remove the screws holding the temperature control in the inset box.
- If needed, remove the control, recording each wire’s terminal.
- Gently pull the control from the cabinet.
- Turn each adjustment screw clockwise 1/4 revolution.
- This raises cut-in and cut-out temperatures about 2 °F.
- Reconnect each wire to its proper terminal before reinstalling.
Manual: page 11
What should I do if the unit arrives damaged?
File a claim with the delivery freight carrier immediately after finding damage.
Manual: page 4
How much product can I load into the unit?
Do not load beyond the product load line marked on the interior wall.
Manual: page 4
How do I clean the condenser coil?
- Disconnect power and remove the lower grill screws.
- Pull the grill gently outward and downward.
- Brush dirt from the condenser coil and clean the fan blade.
- Blow off remaining debris with CO2 or compressed air, then vacuum it up.
- Remove compressor assembly bolts and slide it out carefully; do not bend refrigeration lines.
- Lift the W.R. Board cover at its plastic plugs and clean the coil and fan blade.
- Vacuum dirt from the coil and interior floor.
- Slide the assembly back, replace bolts, reinstall the grill, reconnect power, and check the fan turns.
Manual: page 14
Similar True commercial refrigeration
| True FGD01 | Service Manual | 44 pages |
|---|---|---|
| True TSCI-150PR-SWG-R | Installation Manual | 68 pages |
| True GDM-49-SCI-HC | Installation Manual | 56 pages |
| True GDM-49-SCI-HC | Installation Manual | 56 pages |
| True TBR32-RISZ1-L-B-S-1 | Installation Manual | 56 pages |
| True TBR32-RISZ1-L-B-S-1 | Service Manual | 56 pages |
| True GDM-23-HST02-HC | Installation Manual | 48 pages |
| True GDM-23-HST02-HC | Installation Manual | 48 pages |