Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Wait before use | twice the time it has been laying down (up to four (4) hours)Appliance laid on its back or side24 hoursTime laying down exceeds four (4) hours | p. 12 |
|---|---|---|
| Time to cool down | 24 hoursBefore loading product, run the appliance empty to verify operation.Typical for commercial refrigeration: 1 to 24 hours | p. 30 |
| Clearance above | 0" (0 mm)TBR/TDR modelsTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm) | p. 9 |
| Clearance at the sides | 0" (0 mm)TBR/TDR modelsTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm) | p. 9 |
| Clearance behind | 0" (0 mm) needs less space than mostTBR/TDR modelsTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm) | p. 9 |
| Room temperature range | 60 °F (15.5 °C) to 104 °F (40 °C)For proper operationTypical for commercial refrigeration: 60 to 100 °F (16 to 38 °C) | p. 8 |
True TBR32-RISZ1-L-B-S-1 questions
Answers taken from this manual. Each one links to the page it comes from.
How long should I run the appliance before loading it?
Run the appliance empty for 24 hours before adding product.
Manual: page 30
Why does the temperature display rise or show dEF?
During defrost, dEF may appear and thermometer readings may be higher than normal. Verify product temperature because the control measures coil or air temperature, not product temperature.
Manual: page 32
How do I clean the draft beer dispenser?
Use approved beer-line cleaner and complete the rinse before reconnecting the keg.
- Mix 1/2 oz. (14.2 g) cleaner with each quart of warm water; fill the pump bottle.
- Shut off CO₂ at the regulator and remove the tapping device from the keg.
- Remove the faucet handle, then remove the beer faucet with the spanner wrench.
- Place parts in a bucket; connect the hose and check the rubber gasket for leaks.
- Pump cleaner through the beer lines into the bucket, then wait 10 minutes.
- Brush and rinse faucet parts; rinse the bucket, bottle, and hose with cool water.
- Pump clean cool water through the lines until clear, repeating as needed.
- Reassemble and install the faucet, then reconnect the keg.
Manual: page 40
When should I clean the draft dispenser?
Clean the draft dispenser each time you switch to a fresh keg.
Manual: page 40
What room temperature range is suitable for installation?
For proper operation, the surrounding temperature must stay between 60 °F (15.5 °C) and 104 °F (40 °C).
Other brands: Other not higher than 38℃ · Summit above 44 °F (7 °C) and below 90 °F (32 °C) · EdgeStar 50 °F to 90 °F (10 °C, 32 °C) Compare all
Manual: page 8
How do I install and check the door gasket?
Install the gasket after fitting the hinge components, then check the door closure and seal.
- Remove the existing gasket from the door.
- Install the hinge components.
- Fit the gasket fully into its channel.
- Pull the gasket side outward; the channel should not be visible.
- Reinstall the door and check closure and gaps around the gasket.
What does dEF mean on the display?
It indicates defrost is active; the display may briefly continue showing dEF after defrost ends.
Manual: page 32
How does the appliance clear frost during defrost?
The method depends on the appliance type and temperature control.
- Refrigerator with mechanical control: defrosts during every compressor off-cycle.
- Freezer with mechanical control: defrosts on a defrost timer schedule.
- Refrigerator: evaporator fans clear the coil during defrost.
- Freezer: heaters clear the evaporator coil during defrost.
Manual: page 32
True TBR32-RISZ1-L-B-S-1 compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| True TBR32-RISZ1-L-B-S-1 | EdgeStar VBM101SS | Randell MNL2503 | Other Commercial Refrigerator | |
|---|---|---|---|---|
| Time to cool down | 24 hours | at least 24 hours | about 45 minutes | · |
| Clearance above | 0" (0 mm) | 1/2” | 0 inches (0 cm) | 12" (30.5 cm) |
| Clearance at the sides | 0" (0 mm) | 1/2” | 0 inches (0 cm) | 2" (5.1 cm) |
| Clearance behind | 0" (0 mm) | 3/4” | 0 inches (0 cm) | 2" (5.1 cm) |
| Room temperature range | 60 °F (15.5 °C) to 104 °F (40 °C) | 50 °F to 90 °F (10 °C, 32 °C) | 70 °F (21 °C) - 86 °F (32 °C) | below 90 °F (32 °C) |
Similar True commercial refrigeration
| True TBR32-RISZ1-L-B-S-1Model family TBR32RISZ1LBS1 | Installation Manual | 56 pages |
|---|---|---|
| True TDM-DZ-59-GE | Installation Manual | 31 pages |
| True TBB-1-HC | Installation & Operation Manual | 28 pages |
| True TDC-47 | Installation Manual | 20 pages |
| True TDBD-72-4 | Installation Manual | 18 pages |
| True TSCI-150PR-SWG-R | Installation Manual | 68 pages |
| True GDM-49-SCI-HC | Installation Manual | 56 pages |
| True GDM-49-SCI-HC | Installation Manual | 56 pages |