Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Freezer factory setting-10 °F to 8 °F (-23.3 °C to -13.3 °C) colder than mostfactory setting for freezersTypical for commercial refrigeration: -4 to 0 °F (-20 to -18 °C)p. 10
Time to cool downtwo to three days longer than mostrecommended empty run before loading productTypical for commercial refrigeration: 1 to 24 hoursp. 10
DefrostmanualTFM/TDC mechanical temperature controloff cycle defrostevaporator coil sensing temperature controlp. 11
Room temperature range75˚F / 55% humiditymaximum ambient operating temperatureTypical for commercial refrigeration: 60 to 100 °F (16 to 38 °C)p. 8

True TDC-47 questions

Answers taken from this manual. Each one links to the page it comes from.

What number should I set the mechanical temperature control to?

#4 or #5 is recommended; #1 is warmest, #9 is coldest, and #0 turns it off.

Manual: page 11

Can I adjust the temperature control for my installation?

Only for a high-altitude location. Upright units ordered with high-altitude controls are pre-calibrated and need no adjustment.

Manual: page 12, page 13

How much space should loaded product leave near the evaporator housing?

Keep product at least four inches from the evaporator housing and away from the back wall.

Manual: page 10

How is defrosting handled in this freezer?

Off cycle defrost keeps the evaporator coil clear by delaying compressor restart until the coil is above freezing. The control does not start defrosting, so manually defrost the cabinet; frequency depends on usage, environment, and frost amount.

Manual: page 11

How do I replace the light bulb?
  1. Turn the Light Switch off before changing the bulb.
  2. Grip the bulb end and pull it toward the cabinet center.
  3. Install the replacement bulb with its prongs seated correctly in the lampholders.

Manual: page 19

True TDC-47 compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

True TDC-47Other Commercial RefrigeratorSummit FF64BCSSU-Line UCRE552-SS61A
Freezer factory setting-10 °F to 8 °F (-23.3 °C to -13.3 °C)-7°Fto -1 °F (-22 °C, -18 °C)0 °F/-18 °C-22 °C (-4 °F)
Room temperature range75˚F / 55% humiditybelow 90 °F (32 °C)above 44 °F (7 °C) and below 90 °F (32 °C)10 °C to 40 °C (50 °F, 104 °F)

Similar True commercial refrigeration

True TBR32-RISZ1-L-B-S-1Installation Manual56 pages
True TBR32-RISZ1-L-B-S-1Service Manual56 pages
True TDM-DZ-59-GEInstallation Manual31 pages
True TDBD-72-4Installation Manual18 pages
True TSCI-150PR-SWG-RInstallation Manual68 pages
True GDM-49-SCI-HCInstallation Manual56 pages
True GDM-49-SCI-HCInstallation Manual56 pages
True GDM-23-HST02-HCInstallation Manual48 pages
All True commercial refrigeration →