Have a question about the True GDM-23-HST02-HC? The AI assistant looks through this manual and shows the pages with the answer.
Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Door-open alarm after | five (5) consecutive minDoor left openTypical for commercial refrigeration: 1 to 5 minutes | p. 26 |
|---|---|---|
| Clearance above | 0" (0 mm)RefrigeratorsTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm) | p. 12 |
| Clearance at the sides | 0" (0 mm)RefrigeratorsTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm) | p. 12 |
| Clearance behind | 1" (25.4 mm)RefrigeratorsTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm) | p. 12 |
True GDM-23-HST02-HC questions
Answers taken from this manual. Each one links to the page it comes from.
What temperatures trigger the health safety alarm?
What do hSt and dLY mean during startup?
During startup, hSt and dLY show that Product Loading Delay is active, preventing a false alarm while the appliance reaches temperature. The delay is 30 min for refrigerators and 75 min for freezers.
Manual: page 25
How do I clean the door gasket?
Use warm, soapy water on the gasket. Do not scrape it with knives or other sharp tools.
Manual: page 39
What does dEF mean on the display?
dEF indicates the appliance is defrosting; freezer compressors and evaporator fans stop while electric heaters clear the coil.
Manual: page 26
Why do hST and dLY appear after defrosting?
They indicate a 30-minute delay after defrost ends, during which the control delays showing the temperature.
Manual: page 26
How do I prepare the battery backup at startup?
Turn the battery backup system on during installation; it ships with its power switch OFF.
Manual: page 27
What does PF mean after the power goes out?
PF means Power failure. The battery backup keeps temperature monitoring and lock operation powered for a minimum of 2 hours, but cooling stops.
Manual: page 27
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| dEF | Defrost is in progress | p. 29 | |
| dLc | Door lock or unlock password entry | p. 29 | |
| do | Door open alarm | p. 29 | |
| E1 | Probe t1 has failed | p. 29 | |
| E2 | Probe t2 has failed | p. 29 | |
| E3 | Probe t3 has failed | p. 29 | |
| Edt | End time for timed actions | p. 29 | |
| hi | Appliance high temperature alarm | p. 29 | |
| hLA/Loc | Health Safety Alarm or lockout is active | p. 29 | |
| hrS | Hours of the real time clock | p. 29 | |
| hSt | Health Safety Timer password entry | p. 29 | |
| hSt/dLY | Delays checking Health Safety Timer conditions | p. 29 | |
| hSt/tSt | Tests the Health Safety Lock | p. 29 | |
| Lo | Appliance low temperature alarm | p. 29 | |
| Loc | Keypad is locked | p. 29 | |
| min | Minute of the real time clock | p. 29 | |
| oFF | Controller is in standby | p. 29 | |
| PF | Power failure | p. 29 | |
| Stt | Start time for timed actions | p. 29 | |
| t1 | Instant temperature from probe 1 | p. 29 | |
| t2 | Instant temperature from probe 2 | p. 29 | |
| t3 | Instant temperature from probe 3 | p. 29 | |
| thi | Maximum recorded temperature from probe 3 | p. 29 | |
| tLo | Minimum recorded temperature from probe 3 | p. 29 |
True GDM-23-HST02-HC compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| True GDM-23-HST02-HC | Summit AL57G | EdgeStar VBM101SS | Gram Commercial Refrigerator | |
|---|---|---|---|---|
| Door-open alarm after | five (5) consecutive min | 60 seconds | more than three (3) minutes | more than 2 minutes |
| Clearance above | 0" (0 mm) | 2 to 3 mm (about 1/10") | 1/2” | 250 mm (9.8 in) |
| Clearance at the sides | 0" (0 mm) | 5 inches (127mm) (12.7 cm) | 1/2” | 20 mm (0.8 in) |
| Clearance behind | 1" (25.4 mm) | 5 inches (127mm) (12.7 cm) | 3/4” | max. 75 mm (3 in) |
Similar True commercial refrigeration
| True GDM-23-HST02-HCModel family GDM23HST02HC | Installation Manual | 48 pages |
|---|---|---|
| True GDM-05-HC-LDModel family GDM05H | Installation & Operation Manual | 40 pages |
| True GDM-26-HCModel family GDM26H | Service Manual | 40 pages |
| True GDM-05-HC-LDModel family GDM05H | Service Manual | 20 pages |
| True GDM-49-SCI-HCModel family GDM49 | Installation Manual | 56 pages |
| True GDM-49-SCI-HCModel family GDM49 | Installation Manual | 56 pages |
| True TGO-27-POP01Model family TGO27 | Installation Manual | 47 pages |
| True TGO-27-POP01Model family TGO27 | Service Manual | 44 pages |