Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Clearance behindat least 15 ㎝space between the unit and the wall, for air circulationTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 7
Defrostautomaticp. 23

Turbo Air KGR12-2 questions

Answers taken from this manual. Each one links to the page it comes from.

How much space should I leave between the unit and the wall?

At least 15 ㎝ from the wall is required for air circulation.

Manual: page 7

How do I start a manual defrost cycle?
  1. Press both temperature-adjustment buttons for Five seconds.
  2. Press the down button once.
  3. Press the down button once again.
  4. The manual defrost starts and runs from twenty minutes to 40 minutes.

Manual: page 23, page 24

Does this refrigerator defrost automatically?

Yes, the PCB controls the Defrost cycle automatically.

Manual: page 23

How do I change the defrost temperature?
  1. Hold ▼ ▲ button for five seconds.
  2. Press ▼ button twice.
  3. Press ▼ button three times to reach the defrost-temperature setting.
  4. Press ▲ button to change the setting.

Manual: page 27

Why is the compressor not restarting?

4 minutes: the compressor is prevented from restarting during that period after it stops.

Manual: page 29

What happens during automatic defrost?

The refrigerator resumes running after defrosting for 40 minutes.

Manual: page 29

Similar Turbo Air commercial refrigeration

Turbo Air KUCTB2504User Manual26 pages
Turbo Air KUCTB2503User Manual21 pages
Turbo Air TGF-49FService Manual128 pages
Turbo Air PRO-26-2FService Manual54 pages
Turbo Air TSF-23SDService Manual53 pages
Turbo Air M3F24-1Service Manual46 pages
Turbo Air TSF-23SDService Manual46 pages
Turbo Air TST-28SDService Manual34 pages
All Turbo Air commercial refrigeration →