Aspenora error codes

16 Aspenora error and alarm codes from 1 manual: what each code means and what the manual says to do.

16 codes1 manual

Codes and what they mean

As described in each manual. The same code can mean different things on different models, so check the model column.

CodeMeaningWhat to doManual
E1Calibrates the lower temperature setting range.Use UP or DOWN to adjust the parameter.AS-BPR35S
E2Calibrates the upper temperature setting range.Use UP or DOWN to adjust the parameter.AS-BPR35S
E3Calibrates displayed temperatures above minus 6 °C.Use UP or DOWN to adjust the parameter.AS-BPR35S
E4Calibrates displayed temperatures from minus 7 °C to 12 °C.Use UP or DOWN to adjust the parameter.AS-BPR35S
E5Calibrates displayed temperatures below minus 13 °C.Use UP or DOWN to adjust the parameter.AS-BPR35S
E6Sets the temperature at which the compressor starts.Use UP or DOWN to set the value from 1 to 10 °C.AS-BPR35S
E7Sets the temperature at which the compressor stops.Use UP or DOWN to set the value from 1 to 10 °C.AS-BPR35S
E8Resets the control program to factory settings.Hold the plus and minus buttons together for three seconds.AS-BPR35S
F1Input voltage is too low.Recharge the battery or reduce the battery protection level.AS-BPR35S
F2Fan overload protection is active.Turn off the refrigerator for 30 minutes, then restart it.AS-BPR35S
F3The compressor cycles on and off too frequently.Turn off the refrigerator for 30 minutes, then restart it.AS-BPR35S
F4Compressor speed is too low.Turn off the refrigerator for 30 minutes, then restart it.AS-BPR35S
F5Control module overheat protection is active.Move the refrigerator to ventilation, turn it off 30 minutes, and restart it.AS-BPR35S
F6Controller hardware has failed.Turn it off and restart it.AS-BPR35S
F7Temperature sensor has a short circuit.Check the temperature sensor.AS-BPR35S
F8Temperature sensor is out of position.Check the temperature sensor.AS-BPR35S