| Fridge factory setting | “3”Factory setting positionTypical for commercial refrigeration: 35 to 38 °F (2 to 3 °C) | p. 6 |
|---|---|---|
| Fridge adjustment range | “1”-“5”Temperature controller adjustment rangeTypical for commercial refrigeration: 34 to 45 °F (1 to 7 °C) | p. 6 |
| Wait before use | 30 minutesAfter moving the unit, before switching it on | p. 6 |
| Time to cool down | one hourAfter connecting power, keep the unit empty before useTypical for commercial refrigeration: 1 to 24 hours | p. 6 |
| Clearance behind | 20 cm (7.9 in) needs more space than mostMinimum distance between the back and wallTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm) | p. 5 |
| Space to open the doors | 160°Required open angle for the door | p. 5 |
Atosa Commercial Refrigerator questions
Answers taken from this manual. Each one links to the page it comes from.
How do I adjust the storage temperature?
Turn the internal temperature controller according to the ambient temperature and stored food.
- Summer: turn the controller counterclockwise to “2” when ambient temperature is high.
- Winter: turn the controller clockwise to “4” when ambient temperature is low.
Manual: page 6
What do the temperature-control positions mean?
Higher numbers make storage colder; position “0” stops operation, and the factory setting position is “3”.
Manual: page 6
Why is moisture forming on the cabinet or door?
Wipe the moisture with a dry cloth; humid conditions can cause dew on the cabinet or door.
Manual: page 7
How do I remove heavy frost from the evaporator?
Disconnect power before removing heavy frost.
- Remove all items from the cabinet.
- Disconnect the power supply.
- Let the frost melt on its own.
- Clean up the melted water.
- Reconnect the power supply.
Manual: page 6
Atosa Commercial Refrigerator compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Atosa Commercial Refrigerator | Other Commercial Refrigerator | Summit FF64BCSS | Whynter CBM-815WS | |
|---|---|---|---|---|
| Fridge factory setting | “3” | 34 °F to 38 °F (1 °C, 3 °C) | 38 °F, or 3 °C | 38ºF (3ºC) |
| Fridge adjustment range | “1”-“5” | 34 °F to 38 °F (1 °C, 3 °C) | 36 °F to 43 °F (2 °C, 6 °C) | 34 °F - 43 °F / 1 °C - 6 °C |
| Wait before use | 30 minutes | at least 24 hours | about 2 hours | about 4 hours |
| Clearance behind | 20 cm (7.9 in) | 2" (5.1 cm) | 5” (127mm) | at least 5 inches (127mm) (12.7 cm) |
| Space to open the doors | 160° | · | · | · |
Similar Atosa commercial refrigeration
| Atosa MBF8129GR | Owner's Manual | 28 pages |
|---|---|---|
| Atosa MGF24RGR | Owner's Manual | 28 pages |
| Atosa MBF8001GR | Owner's Manual | 24 pages |
| Atosa MCF8703ES | Owner's Manual | 24 pages |
| Atosa Commercial Refrigeration User Manual | User Manual | 24 pages |
| Atosa Commercial Refrigeration User Manual | User Manual | 20 pages |
| Atosa ISU5S-03II | User Manual | 17 pages |