Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Fridge factory setting“3”Factory setting positionTypical for commercial refrigeration: 35 to 38 °F (2 to 3 °C)p. 6
Fridge adjustment range“1”-“5”Temperature controller adjustment rangeTypical for commercial refrigeration: 34 to 45 °F (1 to 7 °C)p. 6
Wait before use30 minutesAfter moving the unit, before switching it onp. 6
Time to cool downone hourAfter connecting power, keep the unit empty before useTypical for commercial refrigeration: 1 to 24 hoursp. 6
Clearance behind20 cm (7.9 in) needs more space than mostMinimum distance between the back and wallTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 5
Space to open the doors160°Required open angle for the doorp. 5

Atosa Commercial Refrigerator questions

Answers taken from this manual. Each one links to the page it comes from.

How do I adjust the storage temperature?

Turn the internal temperature controller according to the ambient temperature and stored food.

  • Summer: turn the controller counterclockwise to “2” when ambient temperature is high.
  • Winter: turn the controller clockwise to “4” when ambient temperature is low.

Manual: page 6

What do the temperature-control positions mean?

Higher numbers make storage colder; position “0” stops operation, and the factory setting position is “3”.

Manual: page 6

Why is moisture forming on the cabinet or door?

Wipe the moisture with a dry cloth; humid conditions can cause dew on the cabinet or door.

Manual: page 7

How do I remove heavy frost from the evaporator?

Disconnect power before removing heavy frost.

  1. Remove all items from the cabinet.
  2. Disconnect the power supply.
  3. Let the frost melt on its own.
  4. Clean up the melted water.
  5. Reconnect the power supply.

Manual: page 6

Atosa Commercial Refrigerator compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Atosa Commercial RefrigeratorOther Commercial RefrigeratorSummit FF64BCSSWhynter CBM-815WS
Fridge factory setting“3”34 °F to 38 °F (1 °C, 3 °C)38 °F, or 3 °C38ºF (3ºC)
Fridge adjustment range“1”-“5”34 °F to 38 °F (1 °C, 3 °C)36 °F to 43 °F (2 °C, 6 °C)34 °F - 43 °F / 1 °C - 6 °C
Wait before use30 minutesat least 24 hoursabout 2 hoursabout 4 hours
Clearance behind20 cm (7.9 in)2" (5.1 cm)5” (127mm)at least 5 inches (127mm) (12.7 cm)
Space to open the doors160°···

Similar Atosa commercial refrigeration

Atosa MBF8129GROwner's Manual28 pages
Atosa MGF24RGROwner's Manual28 pages
Atosa MBF8001GROwner's Manual24 pages
Atosa MCF8703ESOwner's Manual24 pages
Atosa Commercial Refrigeration User ManualUser Manual24 pages
Atosa Commercial Refrigeration User ManualUser Manual20 pages
Atosa ISU5S-03IIUser Manual17 pages
Atosa Commercial Refrigeration User ManualUser Manual16 pages
All Atosa commercial refrigeration →