Related manuals

These manuals share their text with this one.

Atosa Commercial RefrigeratorCommercial RefrigeratorShares large sectionsUser Manual · 16 pages

Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Wait before use24 hoursAfter the equipment tilts during transportation or handling2 hoursBefore starting for the first timep. 5 p. 6
Time to cool down2 hoursFirst operation, without load, before adding foodTypical for commercial refrigeration: 1 to 24 hoursp. 5
Clearance at the sides10cmdistance from the wall or other objectsTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 3
Clearance behind10cm (4inch)Minimum distance from a wall or other airflow obstructionTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 6
Room temperature range16-32℃/60.8-89.6FOperating room temperatureTypical for commercial refrigeration: 60 to 100 °F (16 to 38 °C)p. 6

Atosa Commercial Refrigerator questions

Answers taken from this manual. Each one links to the page it comes from.

How do I change the defrost settings?
  1. Press SET and ▽ for 3 seconds to enter programming mode.
  2. Select id or Md.
  3. Press SET to display the parameter value.
  4. Use △ or ▽ to change the value.
  5. Press SET to save it and move to the next parameter.
  6. Press SET and △ to exit, or wait 15s.

Manual: page 11

What are the controller's defrost interval and maximum duration?

The controller lists these defrost settings:

ParameterMeaningValue
idDefrost cycle interval6h
MdMaximum defrost length15 min

Manual: page 11, page 12

What does a flashing controller indicator mean?
  • Compressor enabled: anti-short cycle delay is enabled by the AC parameter.
  • Defrost in progress: dripping is in progress.
  • Fans output enabled: the fans are delayed after defrost.

Manual: page 11

What do the controller alarm messages mean?

The controller reports these alarm conditions.

MessageMeaning
P1Room probe failure
P2Evaporator probe failure
HA, LAMaximum or minimum temperature alarm
EA, CAExternal or serious external alarm
dADoor Open

Manual: page 12

How long should I wait before starting the display cabinet?
  • 24 hours after the equipment tilts during transportation or handling.
  • 2 hours before starting it for the first time.

Manual: page 5, page 6

How do I clean the display cabinet?
  1. Disconnect the power before cleaning.
  2. Clean the cabinet with neutral detergent and mild water.
  3. Wipe repeatedly with a clean cloth to remove detergent residue.
  4. Use a damp towel on surfaces, avoiding direct water contact.
  5. Let the equipment dry completely before use.

Manual: page 6

What temperature should the display cabinet maintain?

35.6 to 53.6℉ inside, for DSRC and DSRS series.

Manual: page 3

How much space should I leave around the display cabinet?

Leave at least 10cm from the wall or other objects.

Manual: page 3

Atosa Commercial Refrigerator compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Atosa Commercial RefrigeratorOther Commercial RefrigeratorSummit FF64BCSSTrue TBB-1-HC
Wait before use24 hoursat least 24 hoursabout 2 hours24 hours
Time to cool down2 hours··24 hours
Clearance at the sides10cm2" (5.1 cm)5” (127mm)1" (25.4 mm)
Clearance behind10cm (4inch)2" (5.1 cm)5” (127mm)1" (25.4 mm)
Room temperature range16-32℃/60.8-89.6Fbelow 90 °F (32 °C)above 44 °F (7 °C) and below 90 °F (32 °C)·

Similar Atosa commercial refrigeration

Atosa MBF8129GROwner's Manual28 pages
Atosa MGF24RGROwner's Manual28 pages
Atosa MBF8001GROwner's Manual24 pages
Atosa MCF8703ESOwner's Manual24 pages
Atosa Commercial Refrigeration User ManualUser Manual24 pages
Atosa ISU5S-03IIUser Manual17 pages
Atosa MCF8607G1User Manual15 pages
Atosa Commercial Refrigeration User ManualUser Manual12 pages
All Atosa commercial refrigeration →