Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Wait before use2 hoursfirst use24 hoursAfter the equipment tilts during transportation or handlingp. 7 p. 6
Time to cool down2 hoursFirst operation, running without load before adding foodTypical for commercial refrigeration: 1 to 24 hoursp. 6
Clearance behind10cm (4inch)space between the rear unit and the wall or other airflow obstructionsTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 7

Atosa Commercial Refrigerator questions

Answers taken from this manual. Each one links to the page it comes from.

How do I display or adjust the temperature set point?

Press SET for 1 second to display or set the set point.

Manual: page 11

How do I start a manual defrost?

Press and hold DOWN for more than 3s. Defrost starts only when temperature conditions are valid.

Manual: page 12

How often does defrost run, and how long can it last?

The listed defrost settings apply to both product series.

SettingDSRC seriesDSRS series
Interval between defrost cycles4h4h
Maximum defrost length15 min15 min

Manual: page 13

What does E0 mean?

E0 means probe 1 has a control error; the buzzer and alarm relay are active.

Manual: page 12

What should I do after power to the refrigerator is interrupted?

Turn the unit off, then restart it after five (5) minutes when power is interrupted.

Manual: page 7

Can I store products on top of the refrigerator?

No. Do not store materials or products on top of the unit.

Manual: page 7

How do I prepare the display cabinet for first use?
  1. Adjust the four feet until the cabinet is level.
  2. Clean the cabinet parts, bottom cover, and shelf, then reinstall them.
  3. Close the door and connect the cabinet to power.
  4. Turn on the lighting switch and check each shelf light.
  5. Run the cabinet empty for 2 hours.
  6. Add food only after the cabinet temperature reaches the indicated scope.

Manual: page 6

Error codes in this manual

CodeMeaningWhat to do
chtThe condenser is dirty, with a preliminary alarm.p. 12
dFDefrost is currently running.p. 12
dOrThe door is open.p. 12
E0Control probe 1 has failed.p. 12
E1Defrost probe 2 has failed.p. 12
E2Condenser probe 3 has failed.p. 12
EdDefrost stopped because its time limit expired.p. 12
EEThe unit parameters are invalid.p. 12
EFThe operating parameters are invalid.p. 12
EtCA clock alarm is active.p. 12
HIThe temperature is too high.p. 12
IAAn external alarm is active.p. 12
LOThe temperature is too low.p. 12
All Atosa error codes →

Atosa Commercial Refrigerator compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Atosa Commercial RefrigeratorTrue TBB-1-HCKegco XCK-2448IDW RCM-2
Wait before use2 hours24 hoursabout 24 hours1 hour
Time to cool down2 hours24 hours3 to 4 hours12+ hours
Clearance behind10cm (4inch)1" (25.4 mm)1 inch (2.5 cm)4”

Similar Atosa commercial refrigeration

Atosa MBF8129GROwner's Manual28 pages
Atosa MGF24RGROwner's Manual28 pages
Atosa MBF8001GROwner's Manual24 pages
Atosa MCF8703ESOwner's Manual24 pages
Atosa Commercial Refrigeration User ManualUser Manual24 pages
Atosa ISU5S-03IIUser Manual17 pages
Atosa MCF8607G1User Manual15 pages
Atosa Commercial Refrigeration User ManualUser Manual12 pages
All Atosa commercial refrigeration →