Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Fridge factory setting38º Frefrigerator factory settingTypical for commercial refrigeration: 35 to 38 °F (2 to 3 °C)p. 11
Clearance at the sides0.0 inleft and right sidesTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 7
Clearance behind3.0 inrear, except pass thru modelTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 7
Defrostautomatically defrost as neededp. 12

Beverage-Air MMR19HC********** questions

Answers taken from this manual. Each one links to the page it comes from.

Why does the refrigerator seem to run all the time?
  • Dirty condenser. Clean the condenser.
  • Iced-over evaporator. Defrost the evaporator.
  • High room temperature. Reduce the room temperature.

Manual: page 24

Why is the refrigerator not cooling and silent?
  • Unit unplugged. Connect it to the proper voltage circuit.
  • Tripped fuse or circuit breaker. Replace the fuse or reset the breaker.
  • Loose power cord plug. Check the outlet connection and replace it as needed.

Manual: page 24

What are the cabinet dimensions for the MMR19HC model?

MMR19HC-1 cabinet dimensions are 27 1/4 x 27 1/2 x 78 1/8 inches.

Manual: page 6

The display shows dEF. Is something wrong?

No. dEF indicates defrosting, which is normal operation.

Manual: page 12

Why does the refrigerator fan run continuously?

A continuous fan sound is expected because the Evaporator Fan operates continuously in refrigerators and runs when the unit is plugged in. The Condenser Fan runs only while the Compressor is running.

Manual: page 13

What do the alarm and compressor LEDs mean?

The LED status shows whether an alarm is present and whether the compressor is operating or temporarily blocked.

LED or statusMeaning
Alarm, on fixedALARM Present
Alarm, flashingALARM Silenced
Alarm, offNo Alarm
Compressor, on fixedCompressor active
Compressor, flashingDelay, protection or activation blocked

Manual: page 14

Beverage-Air MMR19HC********** compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Beverage-Air MMR19HC**********Other Commercial RefrigeratorSummit AL57GWhynter CBM-815WS
Fridge factory setting38º F34 °F to 38 °F (1 °C, 3 °C)38 °F, or 3 °C38ºF (3ºC)
Clearance at the sides0.0 in2" (5.1 cm)5 inches (127mm) (12.7 cm)at least 5 inches (127mm) (12.7 cm)
Clearance behind3.0 in2" (5.1 cm)5 inches (127mm) (12.7 cm)at least 5 inches (127mm) (12.7 cm)

Similar Beverage-Air commercial refrigeration

Beverage-Air MMFOperating Instructions26 pages
Beverage-Air MT08-1[#]User Manual69 pages
Beverage-Air BF200RB-PFO-XLOperating Instructions74 pages
Beverage-Air PR3HC-1A*S******Installation & Operation Manual54 pages
Beverage-Air BB58HC****G*******Installation & Operation Manual46 pages
Beverage-Air DD58HC****G*******Installation & Operation Manual39 pages
Beverage-Air 3071629RV05Operating Instructions39 pages
Beverage-Air UCRFOperating Instructions34 pages
All Beverage-Air commercial refrigeration →