Have a question about the True TGO-27-POP01? The AI assistant looks through this manual and shows the pages with the answer.
Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Wait before use | twice the time it has been laying down (up to four (4) hours); 24 hoursAppliance laid on its back or side; if laying-down time exceeds four (4) hours | p. 14 |
|---|---|---|
| Time to cool down | 30 minRefrigerator startup loading delay75 minFreezer startup loading delayTypical for commercial refrigeration: 1 to 24 hours | p. 26 |
| Door-open alarm after | five (5) consecutive min.Door left openTypical for commercial refrigeration: 1 to 5 minutes | p. 27 |
| Clearance above | 0" (0 mm)TGO RefrigeratorTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm) | p. 12 |
| Clearance at the sides | 0" (0 mm)TGO RefrigeratorTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm) | p. 12 |
| Clearance behind | 1" (25.4 mm)TGO RefrigeratorTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm) | p. 12 |
True TGO-27-POP01 questions
Answers taken from this manual. Each one links to the page it comes from.
How long is the startup loading delay?
The startup loading delay is 30 min for refrigerators and 75 min for freezers.
| Appliance | Delay |
|---|---|
| Refrigerator | 30 min |
| Freezer | 75 min |
Manual: page 26
What clearance does the TGO Refrigerator need around it?
For the TGO Refrigerator, provide these minimum spaces for ventilation.
| Location | Minimum clearance |
|---|---|
| Top | 0" (0 mm) |
| Sides | 0" (0 mm) |
| Back | 1" (25.4 mm) |
Other brands: Other 12" (30.5 cm) · Summit 4“(102mm) · EdgeStar 1/2” Compare all
Manual: page 12
How should I clean the door gasket?
Use warm soapy water; do not scrape the gasket with sharp tools or knives, and avoid full-strength cleaning products.
Manual: page 43
What does dEF mean on the display?
dEF means defrost is running; freezers stop the compressor and evaporator fan while electric heaters clear frost.
Manual: page 27
How long do hST and dLY show after defrost?
30 minutes, the digital control alternates hST and dLY after defrost ends.
Manual: page 27
How do I turn the electronic control off and back on?
Press and hold cancel until oFF appears. This does not disconnect appliance power.
- Press and hold cancel until the display shows oFF.
- Press and hold cancel until the display shows on.
Manual: page 30
The display shows PF. What does it mean?
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| dEF | Defrost is in progress | p. 29 | |
| dLc | Door lock or unlock password entry | p. 29 | |
| do | Door open alarm | p. 29 | |
| E1 | Probe 1 failure | p. 29 | |
| E2 | Probe 2 failure | p. 29 | |
| E3 | Probe 3 failure | p. 29 | |
| Edt | End time for timed actions | p. 29 | |
| hi | Appliance high temperature alarm | p. 29 | |
| hLA/Loc | Health Safety alarm or lockout is active | p. 29 | |
| hrS | Hours of the real time clock | p. 29 | |
| hSt | Health Safety Timer password entry | Press Info to display hSt. | p. 29 |
| hSt/dLY | Delay for checking Health Safety Timer conditions | p. 29 | |
| hSt/tSt | Testing the Health Safety Lock | p. 29 | |
| Lo | Appliance low temperature alarm | p. 29 | |
| Loc | Keypad is locked | Press the Down arrow until Loc appears. | p. 29 |
| min | Minute of the real time clock | p. 29 | |
| oFF | Controller is in standby | Press and hold Cancel until oFF appears. | p. 29 |
| on | Control is turned on | Press and hold Cancel until on appears. | p. 30 |
| PF | Power failure | p. 29 | |
| Stt | Start time for timed actions | p. 29 | |
| t1 | Instant temperature from probe 1 | p. 29 | |
| t2 | Instant temperature from probe 2 | p. 29 | |
| t3 | Instant temperature from probe 3 | p. 29 | |
| thi | Maximum recorded probe 3 temperature | p. 29 | |
| tLo | Minimum recorded probe 3 temperature | p. 29 |
True TGO-27-POP01 compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| True TGO-27-POP01 | EdgeStar VBM101SS | Summit FF64BCSS | Gram Commercial Refrigerator | |
|---|---|---|---|---|
| Time to cool down | 30 min | at least 24 hours | · | · |
| Door-open alarm after | five (5) consecutive min | more than three (3) minutes | 60 seconds | more than 2 minutes |
| Clearance above | 0" (0 mm) | 1/2” | 4” (102mm) | 250 mm (9.8 in) |
| Clearance at the sides | 0" (0 mm) | 1/2” | 5” (127mm) | 20 mm (0.8 in) |
| Clearance behind | 1" (25.4 mm) | 3/4” | 5” (127mm) | max. 75 mm (3 in) |
Similar True commercial refrigeration
| True TGO-27-POP01Model family TGO27POP01 | Service Manual | 44 pages |
|---|---|---|
| True GDM-49-SCI-HCModel family GDM49 | Installation Manual | 56 pages |
| True GDM-49-SCI-HCModel family GDM49 | Installation Manual | 56 pages |
| True GDM-23-HST02-HCModel family GDM23 | Installation Manual | 48 pages |
| True GDM-23-HST02-HCModel family GDM23 | Installation Manual | 48 pages |
| True GDM-26-HCModel family GDM26 | Service Manual | 40 pages |
| True TSCI-150PR-SWG-R | Installation Manual | 68 pages |
| True FGD01 | Service Manual | 44 pages |