Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Wait before usetwice the time it has been laying down (up to four (4) hours); 24 hoursAppliance laid on its back or side; if laying-down time exceeds four (4) hoursp. 14
Time to cool down30 minRefrigerator startup loading delay75 minFreezer startup loading delayTypical for commercial refrigeration: 1 to 24 hoursp. 26
Door-open alarm afterfive (5) consecutive min.Door left openTypical for commercial refrigeration: 1 to 5 minutesp. 27
Clearance above0" (0 mm)TGO RefrigeratorTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 12
Clearance at the sides0" (0 mm)TGO RefrigeratorTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 12
Clearance behind1" (25.4 mm)TGO RefrigeratorTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 12

True TGO-27-POP01 questions

Answers taken from this manual. Each one links to the page it comes from.

How long is the startup loading delay?

The startup loading delay is 30 min for refrigerators and 75 min for freezers.

ApplianceDelay
Refrigerator30 min
Freezer75 min

Manual: page 26

What clearance does the TGO Refrigerator need around it?

For the TGO Refrigerator, provide these minimum spaces for ventilation.

LocationMinimum clearance
Top0" (0 mm)
Sides0" (0 mm)
Back1" (25.4 mm)

Other brands: Other 12" (30.5 cm) · Summit 4“(102mm) · EdgeStar 1/2” Compare all

Manual: page 12

How should I clean the door gasket?

Use warm soapy water; do not scrape the gasket with sharp tools or knives, and avoid full-strength cleaning products.

Manual: page 43

What does dEF mean on the display?

dEF means defrost is running; freezers stop the compressor and evaporator fan while electric heaters clear frost.

Manual: page 27

How long do hST and dLY show after defrost?

30 minutes, the digital control alternates hST and dLY after defrost ends.

Manual: page 27

How do I turn the electronic control off and back on?

Press and hold cancel until oFF appears. This does not disconnect appliance power.

  1. Press and hold cancel until the display shows oFF.
  2. Press and hold cancel until the display shows on.

Manual: page 30

The display shows PF. What does it mean?

PF means power failure. Cooling is unavailable, while the battery backup maintains temperature monitoring and lock operation for a minimum of 2 hours.

Manual: page 28, page 29

What does hLA/Loc mean, and why is the door locked?

The Health Safety Alarm and lockout are active, so the door is mechanically locked. Unlock it with the provided key; the alarm remains active until cleared through the control.

Manual: page 28, page 29

Error codes in this manual

CodeMeaningWhat to do
dEFDefrost is in progressp. 29
dLcDoor lock or unlock password entryp. 29
doDoor open alarmp. 29
E1Probe 1 failurep. 29
E2Probe 2 failurep. 29
E3Probe 3 failurep. 29
EdtEnd time for timed actionsp. 29
hiAppliance high temperature alarmp. 29
hLA/LocHealth Safety alarm or lockout is activep. 29
hrSHours of the real time clockp. 29
hStHealth Safety Timer password entryPress Info to display hSt.p. 29
hSt/dLYDelay for checking Health Safety Timer conditionsp. 29
hSt/tStTesting the Health Safety Lockp. 29
LoAppliance low temperature alarmp. 29
LocKeypad is lockedPress the Down arrow until Loc appears.p. 29
minMinute of the real time clockp. 29
oFFController is in standbyPress and hold Cancel until oFF appears.p. 29
onControl is turned onPress and hold Cancel until on appears.p. 30
PFPower failurep. 29
SttStart time for timed actionsp. 29
t1Instant temperature from probe 1p. 29
t2Instant temperature from probe 2p. 29
t3Instant temperature from probe 3p. 29
thiMaximum recorded probe 3 temperaturep. 29
tLoMinimum recorded probe 3 temperaturep. 29
All True error codes →

True TGO-27-POP01 compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

True TGO-27-POP01EdgeStar VBM101SSSummit FF64BCSSGram Commercial Refrigerator
Time to cool down30 minat least 24 hours··
Door-open alarm afterfive (5) consecutive minmore than three (3) minutes60 secondsmore than 2 minutes
Clearance above0" (0 mm)1/2”4” (102mm)250 mm (9.8 in)
Clearance at the sides0" (0 mm)1/2”5” (127mm)20 mm (0.8 in)
Clearance behind1" (25.4 mm)3/4”5” (127mm)max. 75 mm (3 in)

Similar True commercial refrigeration

True TGO-27-POP01Model family TGO27POP01Service Manual44 pages
True GDM-49-SCI-HCModel family GDM49Installation Manual56 pages
True GDM-49-SCI-HCModel family GDM49Installation Manual56 pages
True GDM-23-HST02-HCModel family GDM23Installation Manual48 pages
True GDM-23-HST02-HCModel family GDM23Installation Manual48 pages
True GDM-26-HCModel family GDM26Service Manual40 pages
True TSCI-150PR-SWG-RInstallation Manual68 pages
True FGD01Service Manual44 pages
All True commercial refrigeration →