Related manuals

These manuals share their text with this one.

Continental Refrigerator DRA118NSSDRA118NSS, DRA118NSSBS, DRA43NSS, DRA43NSSBS, DRA43SNSS, DRA43SNSSBS …Shares large sectionsInstallation & Operation Manual · 36 pages
Continental Refrigerator D27ND27N, D27N-FB, D27N-U, D27NBS, D27NBS-FB, D32N …Shares large sectionsInstallation & Operation Manual · 32 pages
Continental Refrigerator MC3NDMC3ND, MC3NDCW, MC3NS, MC3NSSD, MC3NSSDCW, MC3NSSS …Shares large sectionsInstallation & Operation Manual · 24 pages

Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Fridge factory setting38° to 40 °F (3.3° to 4.4 °C) warmer than mostself-contained refrigeratorsTypical for commercial refrigeration: 35 to 38 °F (2 to 3 °C)p. 11
Recommended fridge temperature38° to 40 °F (3.3° to 4.4 °C)RefrigeratorsTypical for commercial refrigeration: 32 to 40 °F (0 to 4 °C)p. 11
Freezer factory setting-4° to 0 °F (-20° to -18 °C)self-contained freezersTypical for commercial refrigeration: -4 to 0 °F (-20 to -18 °C)p. 12
Recommended freezer temperature-4° to 0 °F (-20° to -18 °C)Freezersp. 12
Time to cool downapproximately 1 hourRefrigerators, reaching 38° to 40 °F (3.3° to 4.4 °C)approximately 2 hoursFreezers, reaching -4° to 0 °F (-20° to -18 °C)Typical for commercial refrigeration: 1 to 24 hoursp. 11
Defrostautomatic, off-cycleRefrigerator modelsautomatic, electricFreezer modelsp. 12

Continental Refrigerator D108GN questions

Answers taken from this manual. Each one links to the page it comes from.

What temperatures should I expect from this refrigerator or freezer?

Use these cabinet temperatures and allow the listed operating time before loading product.

ApplianceCabinet temperatureTime to reach temperature
Refrigerator38° to 40 °F (3.3° to 4.4 °C)approximately 1 hour
Freezer-4° to 0 °F (-20° to -18 °C)approximately 2 hours

Other brands: Other +4 C · Liebherr just above 32 °F (0 °C) · True #4 or #5 Compare all

Manual: page 11

How do I change the electronic temperature set-point?

For electronic controls, adjust the set-point with the control buttons.

  1. Press and hold SET until the current set-point flashes, then release it.
  2. Press UP or DOWN to select the new set-point.
  3. Press and release SET to save the value and resume operation.

Manual: page 13

How long should I wait before restarting the unit after unplugging it?

5-6 minutes, so the system can equalize before restarting the unit.

Manual: page 10

How do I restore the defrost schedule after a power loss?

Reset the defrost timer according to the cabinet type.

  • Refrigerator: Turn the defrost timer knob clockwise until defrost begins, then repeat every 8 hours.
  • Freezer: Turn the defrost manual set knob clockwise until defrost begins, then reset it after power loss.

Manual: page 12

How should I dispose of the refrigerator at the end of its useful life?
  1. Remove all doors before disposal to prevent accidental child entrapment.
  2. Arrange for a qualified technician to remove and properly handle the refrigerant and compressor oil.
  3. Recycle or properly dispose of the cabinet and refrigeration components; much of the metal can be recycled.

Manual: page 19

Error codes in this manual

CodeMeaningWhat to do
AHHigh temperature alarm condition.Press and release SET/MUTE to silence the alarm beeper.p. 14
ALLow temperature alarm condition.Press and release SET/MUTE to silence the alarm beeper.p. 14
E0Regulation probe error.Contact your service provider immediately.p. 14
E1Evaporator probe error.p. 14
E2Ambient probe error.p. 14
HIHigh temperature alarm.Press and release SET/MUTE to silence the alarm beeper.p. 14
LOLow temperature alarm.Press and release SET/MUTE to silence the alarm beeper.p. 14
All Continental Refrigerator error codes →

Continental Refrigerator D108GN compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Continental Refrigerator D108GNEverest ESPT-1G-1SU-Line UCRE552-SS61ADelfield Commercial Refrigerator
Fridge factory setting38° to 40 °F (3.3° to 4.4 °C)35.0 °F (2.0 °C)2 °C (36 °F)35.6 °F (2 °C)
Recommended fridge temperature38° to 40 °F (3.3° to 4.4 °C)35.0 °F (2.0 °C)0 °C to 2 °C (32 °F to 36 °F)36 °F to 40 °F (2 °C to 4 °C)
Freezer factory setting-4° to 0 °F (-20° to -18 °C)-4.0 °F (-20.0 °C)-22 °C (-4 °F)-1.4 °F (-19 °C)
Recommended freezer temperature-4° to 0 °F (-20° to -18 °C)-4.0 °F (-20.0 °C)-22 °C to -20 °C (-7,6 °F to -4 °F)0 °F (-18 °C)
Time to cool downabout 1 hour24 to 72 hours··

Similar Continental Refrigerator commercial refrigeration

Continental Refrigerator 1FENInstallation & Operation Manual44 pages
Continental Refrigerator BB24NInstallation & Operation Manual32 pages
All Continental Refrigerator commercial refrigeration →