As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Fridge factory setting | 35.6 °F (2 °C)Refrigeration factory settingTypical for commercial refrigeration: 35 to 38 °F (2 to 3 °C) | p. 27 |
|---|---|---|
| Recommended fridge temperature | 36 °F to 40 °F (2 °C to 4 °C)Delfield refrigeratorsTypical for commercial refrigeration: 32 to 40 °F (0 to 4 °C) | p. 21 |
| Fridge adjustment range | 30 °F and 60 °F (-1 °C, 16 °C)Refrigeration set point limitsTypical for commercial refrigeration: 34 to 45 °F (1 to 7 °C) | p. 27 |
| Freezer factory setting | -1.4 °F (-19 °C)Freezer factory settingTypical for commercial refrigeration: -4 to 0 °F (-20 to -18 °C) | p. 27 |
| Recommended freezer temperature | 0 °F (-18 °C)Delfield freezers | p. 21 |
| Freezer adjustment range | -5 °F and 36 °F (-21 °C, 2 °C)Freezer set point limitsTypical for commercial refrigeration: -8 to 3 °F (-22 to -16 °C) | p. 27 |
| Clearance above | 12.00” (305mm)Typical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm) | p. 7 |
| Defrost | Adaptive DefrostFactory default | p. 26 |
Delfield Commercial Refrigerator questions
Answers taken from this manual. Each one links to the page it comes from.
Why is water collecting inside or underneath the unit?
- Drain connection is loose. For water inside, reconnect the drain tube to the evaporator drain pan.
- Drain outlet is misplaced. For water below, put the tube end in the condensate evaporator.
- Unit is not level or lines are blocked. Level it and clear drain-line obstructions.
Manual: page 34
Why is condensation forming around the door?
- Frame heater is not set to heat continuously. From Frame Heater, select Always On; access requires the manager password.
- Power Save heats only during compressor operation. Select Always On to heat the door continuously.
Manual: page 37
What top clearance does the equipment require?
12.00” (305mm) of clearance is required above the equipment.
Other brands: Other 12" (30.5 cm) · Summit 4“(102mm) · True 1" (25.4 mm) Compare all
Manual: page 7
How do I clean the door gasket?
- Wash the gasket with water and mild, non-citrus soap.
- Do not use full-strength cleaners, sharp tools, or knives.
- Clean the gasket regularly to limit mold and mildew buildup and preserve flexibility.
Manual: page 34
How do I replace a damaged door gasket?
- Pull the dart-style gasket out of the door groove.
- Soak the replacement gasket in warm water so it becomes more flexible.
- Dry the gasket, then press it into the groove.
- No tools or authorized service person are required for gasket replacement.
Manual: page 34
How long can the initial defrost take after startup?
Up to 35 minutes, then the defrost icon remains for another 30 minutes while the box cools.
Manual: page 22
What does the defrost icon mean on the display?
The unit is in defrost, and the icon replaces the cabinet temperature throughout the defrost process.
Manual: page 24
Delfield Commercial Refrigerator compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Delfield Commercial Refrigerator | U-Line UCRE552-SS61A | Everest EMGR24 | Other Commercial Refrigerator | |
|---|---|---|---|---|
| Fridge factory setting | 35.6 °F (2 °C) | 2 °C (36 °F) | 35.0 °F (2.0 °C) | 34 °F to 38 °F (1 °C, 3 °C) |
| Recommended fridge temperature | 36 °F to 40 °F (2 °C to 4 °C) | 0 °C to 2 °C (32 °F to 36 °F) | 35.0 °F (2.0 °C) | · |
| Fridge adjustment range | 30 °F and 60 °F (-1 °C, 16 °C) | -2 °C (-28 °F) to 8 °C (46 °F) | 33.0 °F to 54.0 °F (1.0 °C to 12.0 °C) | 34 °F to 38 °F (1 °C, 3 °C) |
| Freezer factory setting | -1.4 °F (-19 °C) | -22 °C (-4 °F) | -4.0 °F (-20.0 °C) | -7°Fto -1 °F (-22 °C, -18 °C) |
| Recommended freezer temperature | 0 °F (-18 °C) | -22 °C to -20 °C (-7,6 °F to -4 °F) | -4.0 °F (-20.0 °C) | · |
| Freezer adjustment range | -5 °F and 36 °F (-21 °C, 2 °C) | -25 °C (-13 °F) to -10 °C (14 °F) | -10.0 °F to 54.0 °F (-23.0 °C to 12.0 °C) | -7°Fto -1 °F (-22 °C, -18 °C) |
| Clearance above | 12.00” (305mm) | · | · | 12" (30.5 cm) |
Similar Delfield commercial refrigeration
| Delfield DEL1157S | Service Manual | 37 pages |
|---|---|---|
| Delfield Commercial Refrigeration Service Manual | Service Manual | 24 pages |
| Delfield 6000XL | Operating Instructions | 24 pages |
| Delfield D4460N | User Manual | 20 pages |
| Delfield Enodis 400 Series User Manual | User Manual | 16 pages |
| Delfield Commercial Refrigeration User Manual | User Manual | 4 pages |