Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Wait before use24 hoursafter leaving the cabinet upright, before plugging into a power sourcep. 5
Door-open alarm after≥ 60 secwhen the door remains openTypical for commercial refrigeration: 1 to 5 minutesp. 18
Clearance above1" (25.4 mm)TSCI Refrigerator12" Open (304.8 mm)TSCI FreezerTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 4
Clearance at the sides0" (0 mm)TSCI FreezerTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 4
Clearance behind1" (25.4 mm)TSCI Refrigerator3" (76.2 mm)TSCI FreezerTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 4

True Commercial Refrigerator questions

Answers taken from this manual. Each one links to the page it comes from.

Why is the display showing hi?

A cabinet temperature above 46 °F (8 °C) for 5 consecutive minutes triggers the alarm; press any display button to silence it. hi remains until the cabinet drops below 46 °F; alarm values may vary by model.

Manual: page 12

When can I plug in the cabinet after moving it?

Leave the cabinet upright for 24 hours before plugging it into a power source.

Other brands: Other 24 hours · Summit about 2 hours · Whynter about 4 hours Compare all

Manual: page 5

Why does defrost continue after I start it?

The cycle ends only after its preset temperature or duration is reached, clearing frost and ice from the evaporator coil.

Manual: page 15

How do I reset the high or low temperature log?
  1. After 24 hours of operation, reset thi because startup temperatures are typically recorded.
  2. Tap info until thi or tLo appears.
  3. Press and hold info until the logged temperature appears. Do not release info.
  4. Tap cancel to replace the log with the current cabinet temperature.

Manual: page 21

What do the alarm beeps and displays do, hi, and Lo mean?

Each message identifies a different alarm condition.

DisplayCauseAlarm condition
doDoor openOpen for ≥ 60 sec
hiHigh temperature≥ 46 °F (8 °C) for ≥ 5 min
LoLow temperature≤ 36 °F (2 °C) for ≥ 5 min

Manual: page 18

Error codes in this manual

CodeMeaningWhat to do
doDoor openOpen for ≥ 60 secp. 18
hiHigh temperature≥ 46 °F (8 °C) for ≥ 5 minp. 18
LoLow temperature≤ 36 °F (2 °C) for ≥ 5 minp. 18
All True error codes →

True Commercial Refrigerator compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

True Commercial RefrigeratorSummit AL57GGram Commercial RefrigeratorOther Commercial Refrigerator
Wait before use24 hoursat least 2 hoursat least 2 hoursat least 24 hours
Door-open alarm after≥ 60 sec60 secondsmore than 2 minutes·
Clearance above1" (25.4 mm)2 to 3 mm (about 1/10")250 mm (9.8 in)12" (30.5 cm)
Clearance at the sides0" (0 mm)5 inches (127mm) (12.7 cm)20 mm (0.8 in)2" (5.1 cm)
Clearance behind1" (25.4 mm)5 inches (127mm) (12.7 cm)max. 75 mm (3 in)2" (5.1 cm)

Similar True commercial refrigeration

True Commercial Refrigeration Installation ManualInstallation Manual300 pages
True Commercial Refrigeration Installation ManualInstallation Manual240 pages
True TSCI-150PR-SWG-RInstallation Manual68 pages
True GDM-49-SCI-HCInstallation Manual56 pages
True GDM-49-SCI-HCInstallation Manual56 pages
True TBR32-RISZ1-L-B-S-1Installation Manual56 pages
True TBR32-RISZ1-L-B-S-1Service Manual56 pages
True GDM-23-HST02-HCInstallation Manual48 pages
All True commercial refrigeration →