Criterion error codes
25 Criterion error and alarm codes from 4 manuals: what each code means and what the manual says to do.
25 codes4 manuals
Codes and what they mean
As described in each manual. The same code can mean different things on different models, so check the model column.
| Code | Meaning | What to do | Manual |
|---|---|---|---|
| C9 | Ice chamber sensor failure. | Contact maintenance personnel for service. | CFDR286M4S |
| CA | Communication failure between control and ice making boards. | Contact maintenance personnel for service. | CFDR286M4S |
| CC | Ice chamber defrost sensor failure. | Contact maintenance personnel for service. | CFDR286M4S |
| CO | Communication failure | CUF14P1W | |
| dr | Door opening alarm | Close the door. | CUF14P1W |
| E01 | Sensor warning | Call Service for assistance as soon as possible. | CTMR142C1B |
| E02 | Sensor warning | Call Service for assistance as soon as possible. | CTMR142C1B |
| E03 | Sensor warning | Call Service for assistance as soon as possible. | CTMR142C1B |
| E06 | Sensor warning | Call Service for assistance as soon as possible. | CTMR142C1B |
| E07 | Sensor warning | Call Service for assistance as soon as possible. | CTMR142C1B |
| E09 | Freezer compartment is not cold enough | Set the freezer colder or Super Freeze, keep doors closed, remove thawed products, and avoid fresh produce until temperature recovers. | CTMR142C1B |
| E1 | Freezer sensor failure | CUF14P1W | |
| E1 | Refrigerator room temperature sensor failure. | Contact maintenance personnel to ensure normal refrigerator use. | CFDR225M3S |
| E1 | Refrigerator compartment temperature sensor failure. | Contact maintenance personnel for service. | CFDR286M4S |
| E2 | Freezer defrosting sensor failure | CUF14P1W | |
| E2 | Freezer room temperature sensor failure. | Contact maintenance personnel to ensure normal refrigerator use. | CFDR225M3S |
| E2 | Freezer compartment temperature sensor failure. | Contact maintenance personnel for service. | CFDR286M4S |
| E3 | Freezer and defrosting sensor failure | CUF14P1W | |
| E5 | Freezer room defrost sensor error. | Contact maintenance personnel to ensure normal refrigerator use. | CFDR225M3S |
| E5 | Freezer defrost sensor error. | Contact maintenance personnel for service. | CFDR286M4S |
| E6 | Communication error. | Contact maintenance personnel to ensure normal refrigerator use. | CFDR225M3S, CFDR286M4S |
| E7 | Ambient temperature sensor error. | Contact maintenance personnel to ensure normal refrigerator use. | CFDR225M3S, CFDR286M4S |
| E10 | Fridge compartment is not cold enough | Set the fridge colder or Super Cool, keep doors closed, clear air ducts, and keep food away from the sensor. | CTMR142C1B |
| E11 | Fridge compartment is too cold | Check Super Cool, lower the fridge temperature, clear vents, and contact an authorised technician if warning continues. | CTMR142C1B |
| EH | Humidity sensor error. | Contact maintenance personnel to ensure normal refrigerator use. | CFDR225M3S |
| EH | Humidity sensor failure. | Contact maintenance personnel for service. | CFDR286M4S |
| EO | Ice maker error. | Contact maintenance personnel to ensure normal refrigerator use. | CFDR225M3S |
| F4 | Ice maker bottom sensor failure. | Contact maintenance personnel for service. | CFDR286M4S |
| F5 | Ice maker cannot overturn ice. | Contact maintenance personnel for service. | CFDR286M4S |
| F6 | Ice maker initialization fault. | Contact maintenance personnel for service. | CFDR286M4S |
| H1 | Freezer heater failure | CUF14P1W |