Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Fridge adjustment range34 °F to 64 °F (1 °C, 18 °C)commercial refrigerator34 °F - 64° (1 °C)Typical for commercial refrigeration: 34 to 45 °F (1 to 7 °C)p. 16 p. 21
Time to cool downat least 24 hoursafter setting the temperature, before storing beveragesTypical for commercial refrigeration: 1 to 24 hoursp. 17
Door-open alarm aftermore than three (3) minutesdoor left openTypical for commercial refrigeration: 1 to 5 minutesp. 17
Clearance above1/2”for proper air circulationTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 16
Clearance at the sides1/2”for proper air circulationTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 16
Clearance behind3/4” needs less space than mostfor proper air circulationTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 16
Space to open the doors2 1/4”when the door side is against a wallp. 8
Defrostautomatically defrostmost refrigerating settings and most ambient conditionsautodefrostUnder certain conditions, manual defrosting may be required.p. 18 p. 20
Room temperature range50 °F to 90 °F (10 °C, 32 °C)ambient temperature all year roundTypical for commercial refrigeration: 60 to 100 °F (16 to 38 °C)p. 16

EdgeStar VBM101SS questions

Answers taken from this manual. Each one links to the page it comes from.

How do I adjust the refrigerator temperature?
  1. Tap Up Button for a 1° increase.
  2. Tap Down Button for a 1° decrease.
  3. Use C/F Button to switch the display between Celsius and Fahrenheit.

Manual: page 16

How long should I wait before storing beverages after changing the temperature?

Allow at least 24 hours before storing beverages.

Manual: page 17

What clearances does the refrigerator need for built-in installation?

Allow these minimum clearances for ventilation and service access.

LocationMinimum clearance
Back3/4”
Top1/2”
Sides1/2”
Door side against wall2 1/4”

Manual: page 8

What room temperature range is suitable for installation?

Choose a location above 50 °F and below 90 °F.

Other brands: Other not higher than 38℃ · Summit above 44 °F (7 °C) and below 90 °F (32 °C) · True 60 °F (15.5 °C) to 104 °F (40 °C) Compare all

Manual: page 8

How do I defrost the refrigerator when frost blocks the door?
  1. Power the unit off if frost prevents the door from closing.
  2. Wait for the frost to melt.
  3. Dry the unit with a soft absorbent towel; never use a sharp object.

Manual: page 18

Does this refrigerator defrost automatically?

Yes, it automatically defrosts under most refrigerating settings and ambient conditions; colder settings or higher humidity can produce frost.

Manual: page 18

Why won't the commercial refrigerator turn on?
  • Power failure or no power at the outlet. Confirm the refrigerator is plugged in and the outlet has power.
  • The refrigerator is unplugged. Connect it to an outlet with sufficient amperage.
  • A fuse is blown or the breaker is tripped. Replace the fuse or reset the breaker.

Manual: page 19

How do I prepare this refrigerator for long-term storage?

Disconnect power, defrost the refrigerator, and dry its interior before storing it.

  1. Unplug the refrigerator from the wall outlet.
  2. Defrost the unit and dry the interior.
  3. Leave the door open for air circulation and odor prevention.

Manual: page 18

What sounds are normal during operation?

Several operating sounds can occur without indicating a problem.

SoundPossible source
RattlingRefrigerant, water line, or stored items
Pulsating or high-pitchedHigh-efficiency compressor
SplashingWater entering the water bin
GurglingRefrigerant flow after a cycle
Forced-air soundCondenser fan airflow

Manual: page 17

EdgeStar VBM101SS compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

EdgeStar VBM101SSSummit FF64BCSSTrue TGO-27-POP01Gram Commercial Refrigerator
Fridge adjustment range34 °F to 64 °F (1 °C, 18 °C)36 °F to 43 °F (2 °C, 6 °C)·2 to 12 °C (36 to 54 °F)
Time to cool downat least 24 hours·30 min·
Door-open alarm aftermore than three (3) minutes60 secondsfive (5) consecutive minmore than 2 minutes
Clearance above1/2”4” (102mm)0" (0 mm)250 mm (9.8 in)
Clearance at the sides1/2”5” (127mm)0" (0 mm)20 mm (0.8 in)
Clearance behind3/4”5” (127mm)1" (25.4 mm)max. 75 mm (3 in)
Space to open the doors2 1/4”···