Engel error codes
15 Engel error and alarm codes from 5 manuals: what each code means and what the manual says to do.
15 codes5 manuals
Codes and what they mean
As described in each manual. The same code can mean different things on different models, so check the model column.
| Code | Meaning | What to do | Manual |
|---|---|---|---|
| E-01 | Abnormal input voltage | Check whether the power voltage is too low. | MT35F, MT45F, MT35F-U1D-P, MT45F-U1CD-P |
| E-04 | Ambient temperature is too low | Check whether the ambient temperature is too low. | MT35F, MT45F, MT35F-U1D-P, MT45F-U1CD-P |
| E-05 | Temperature sensor cord is shorted | Contact a service agent. | MT35F, MT45F, MT35F-U1D-P, MT45F-U1CD-P |
| E-06 | Temperature sensor cord is open | Contact a service agent. | MT35F, MT45F, MT35F-U1D-P, MT45F-U1CD-P |
| E-07 | Abnormal input voltage, too high | Check whether the power voltage is too high. | MT35F |
| E-07 | Input voltage is abnormally high | Check whether the power voltage is too high. | MT45F |
| E-07 | Abnormally high input voltage. | Check whether the power voltage is too high. | MT35F-U1D-P, MT45F-U1CD-P |
| E-08 | Fridge side temperature sensor cord is shorted | Contact a service agent. | MT45F |
| E-08 | Fridge temperature sensor cord is shorted | Contact a service agent. | MT45F-U1CD-P |
| E-09 | Fridge side temperature sensor cord is open | Contact a service agent. | MT45F |
| E-09 | Fridge temperature sensor cord is open | Contact a service agent. | MT45F-U1CD-P |
| E-4 | Ambient temperature around the board is too low. | Reset power and move the refrigerator somewhere warmer. | MT35F-U1D-P |
| E-5 | Evaporator thermistor is shorted or internal temperature is too high. | Reset power and inspect the evaporator thermistor. | MT35F-U1D-P |
| E-6 | Evaporator thermistor is disconnected or internal temperature is too low. | Reset power and inspect the evaporator thermistor. | MT35F-U1D-P |
| E-7 | DC input voltage is abnormally high. | Reset power and check the battery. | MT35F-U1D-P |
| E-8 | Internal thermistor is shorted or internal temperature is too high. | Reset power and inspect the internal thermistor. | MT35F-U1D-P |
| E-9 | Internal thermistor is disconnected or internal temperature is too low. | Reset power and inspect the internal thermistor. | MT35F-U1D-P |
| E-10 | Fridge side fan cord is open | Contact a service agent. | MT45F |
| E-10 | Internal fan motor is disconnected. | Reset power and inspect the internal fan motor. | MT35F-U1D-P |
| E-10 | Fridge fan cord is open | Contact a service agent. | MT45F-U1CD-P |
| OFF | Abnormal DC voltage input. | Check the battery. | MT35F-U1D-P |