Have a question about the Gram Commercial Refrigerator? The AI assistant looks through this manual and shows the pages with the answer.
Same manual for other models
These manuals share their text with this one.
| Gram Commercial RefrigeratorCommercial Refrigerator | Same manual | Service Manual · 28 pages |
|---|---|---|
| Gram Commercial RefrigeratorCommercial Refrigerator | Same manual | Service Manual · 29 pages |
Gram Commercial Refrigerator questions
Answers taken from this manual. Each one links to the page it comes from.
How do I change the temperature setpoint?
- Hold the setpoint control.
- While holding it, press a temperature adjustment control.
- Each press changes the temperature by one degree.
- Release the controls after setting the desired value; a beep confirms it was saved.
Manual: page 7
What does the potential free alarm relay do?
The potential free alarm relay changes position when the cabinet powers on, then returns during alarms or power failure.
Manual: page 20
What do the different defrost modes mean?
The defrost mode varies by cabinet type.
- Defrost mode: Air means the evaporator fan runs at 100 % in a refrigerator.
- Defrost mode: Automatic selects the fan or electrical heater by setpoint in an extended refrigerator.
- Defrost mode: Electrical uses the heater below the evaporator in a freezer.
Manual: page 6
Why does the refrigerator display only +5 °C after startup?
Because the cabinet has not run before, the display shows the setpoint, and +5 °C is the refrigerator's standard setpoint.
Manual: page 6
Can I change the temperature scale?
Yes. The menu includes a choice between Celsius and Fahrenheit temperature scales.
Manual: page 11
What does P4 control?
P4 filters temperature fluctuations around the setpoint.
Manual: page 11
What happens on the display during startup?
- The software loads into MPC-46, and all display segments illuminate white for a control check.
- At approximately the 3rd second, the display identifies version 3.0 and waits for further information.
- At approximately the 7th second, it identifies programme variant F3+, version 3.0, and activates the required lamps.
- At approximately the 10th second, only the compressor lamp remains lit and the large display becomes ready.
Manual: page 4
How many compressors does the startup display identify?
One compressor is identified by the display.
Manual: page 4
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| -0- | Condenser 1 and 2 are overheated. | p. 15 | |
| A1 | Alarm triggered by a door left open too long. | p. 15 | |
| F1 | Room sensor error. | p. 15 | |
| F2 | Evaporator sensor error. | p. 15 | |
| F3 | Condenser sensor 1 error. | p. 15 | |
| F4 | Condenser sensor 2 error. | p. 15 | |
| F7 | Condenser 1 and 2 are overheated. | p. 15 |
Similar Gram commercial refrigeration
| Gram Commercial Refrigeration Instruction Manual | Instruction Manual | 154 pages |
|---|---|---|
| Gram Commercial Refrigeration User Manual | User Manual | 140 pages |
| Gram IO-REF-1455 | Instruction Manual | 132 pages |
| Gram Commercial Refrigeration Instruction Manual | Instruction Manual | 131 pages |
| Gram COMPACT 600 Gram Refrigerator | User Manual | 124 pages |
| Gram IO-REF-1453 | Instruction Manual | 124 pages |
| Gram IO-REF-1421 | Instruction Manual | 120 pages |
| Gram IO-REF-1419 | Operating Instructions | 120 pages |