Have a question about the Gram Commercial Refrigerator? The AI assistant looks through this manual and shows the pages with the answer.
Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Defrost | automatically performed 4 times every 24 hourscounterautomaticcounter | p. 40 |
|---|
Gram Commercial Refrigerator questions
Answers taken from this manual. Each one links to the page it comes from.
How do I view the cabinet's temperature setting?
Press P to show the cabinet's set temperature on the display.
Manual: page 37
Why is frost forming inside the commercial refrigerator?
Frost inside the compartment can result from high humidity, frequent or prolonged door opening, or a damaged door gasket.
Manual: page 38
What causes condensation around the door?
High humidity, an incompletely closed door, or a damaged door gasket can cause condensation around the door.
Manual: page 38
Does the cabinet defrost when it starts?
Yes. At startup, the cabinet runs a defrost, then ends it shortly after the system check.
Manual: page 36
Why can the cabinet temperature rise during defrost?
A temporary temperature increase can occur during a defrost cycle, and it will not affect the food inside.
Manual: page 38
What happens when power returns after an outage?
The control restarts the counter when power returns and retains the temperature setting; a prolonged outage may restore factory settings.
Manual: page 41
Why is my counter making unusual noises?
- Normal operating sounds. Compressor, condenser fan, and interior fan sounds are normal.
- Loose panels. Close sheet metal, front, or compressor-compartment panels that may be open.
- Abnormal noise. Request service assistance.
Manual: page 38
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| A2 | Local upper limit alarm has been or is currently activated. | Press P to acknowledge the alarm. | p. 18 |
| A4 | External upper limit alarm has been or is currently activated. | Press P to acknowledge the alarm. | p. 18 |
| A5 | External lower limit alarm has been activated. | Press P to acknowledge the alarm. | p. 56 |
| F1 | Room temperature sensor is faulty, affecting temperature stability. | Have the sensor replaced by service. | p. 18 |
| F2 | Evaporator sensor is faulty. | Have the sensor replaced by service as soon as possible. | p. 18 |
| F3 | Condenser sensor is faulty. | Have the sensor replaced by service. | p. 18 |
| F7 | Condenser temperature is too high. | Disconnect power, clean the condenser or filter, improve ventilation, and contact service if unresolved. | p. 18 |
Similar Gram commercial refrigeration
| Gram Commercial Refrigeration Instruction Manual | Instruction Manual | 154 pages |
|---|---|---|
| Gram Commercial Refrigeration User Manual | User Manual | 140 pages |
| Gram IO-REF-1455 | Instruction Manual | 132 pages |
| Gram COMPACT 600 Gram Refrigerator | User Manual | 124 pages |
| Gram IO-REF-1453 | Instruction Manual | 124 pages |
| Gram IO-REF-1421 | Instruction Manual | 120 pages |
| Gram IO-REF-1419 | Operating Instructions | 120 pages |
| Gram 6C1854 | Operating Instructions | 120 pages |