Gram error codes

39 Gram error and alarm codes from 15 manuals: what each code means and what the manual says to do.

39 codes15 manuals

Codes and what they mean

As described in each manual. The same code can mean different things on different models, so check the model column.

CodeMeaningWhat to doManual
-0-Overheated condenser.Commercial Refrigerator
-0-Condenser 1 and 2 are overheated.Commercial Refrigerator, Commercial Refrigerator
-oA1The door is open.Commercial Refrigerator, 765041500GB
A0Current or ongoing temperature alarm.A current alarm cannot be reset or deleted.Commercial Refrigerator
A0Present or ongoing temperature alarm.It cannot be reset or deleted while present.Commercial Refrigerator
A1The door alarm was activated.Close the door, then press the button to delete the alarm.Commercial Refrigerator
A1Alarm triggered after the door remains open too long.Commercial Refrigerator, Commercial Refrigerator
A1Alarm triggered by a door left open too long.Commercial Refrigerator
A1The local door alarm is active.765041500GB
A1 / OPThe door remains open or is not closed correctly.Press P to confirm the alarm.Commercial Refrigerator, Commercial Refrigerator
A1..A10Logged temperature alarms that are no longer present.Review alarms, then verify them or hold five seconds to delete them.Commercial Refrigerator
A2The local maximum temperature alarm was activated.Wait until temperature is below the maximum, then press the button.Commercial Refrigerator
A2The cabinet has a high internal temperature.Press P to confirm the alarm.Commercial Refrigerator
A2Local high temperature alarm.Press P to acknowledge the alarm.Commercial Refrigerator
A2Local upper limit alarm has been or is currently activated.Press P to acknowledge the alarm.Commercial Refrigerator
A2The door alarm was activated.Press P to acknowledge the alarm.Commercial Refrigerator
A2The upper alarm limit has been reached.765041500GB
A3The external upper alarm limit has been reached.765041500GB
A4The cabinet has a high external temperature.Press P to confirm the alarm.Commercial Refrigerator
A4External high temperature alarm.Press P to acknowledge the alarm.Commercial Refrigerator
A4External upper limit alarm has been or is currently activated.Press P to acknowledge the alarm.Commercial Refrigerator
A4The local maximum temperature alarm was activated.Press P to acknowledge the alarm.Commercial Refrigerator
A4The lower alarm limit has been reached.765041500GB
A5External lower limit alarm has been activated.Press P to acknowledge the alarm.Commercial Refrigerator
A5The external minimum temperature alarm was activated.Press P to acknowledge the alarm.Commercial Refrigerator
AhHigh temperature alarm.Commercial Refrigerator, Commercial Refrigerator, Commercial Refrigerator
ALLow temperature alarm.Commercial Refrigerator, Commercial Refrigerator, Commercial Refrigerator
COHCondenser temperature is too high.Commercial Refrigerator
CSdCompressor blocked because condenser temperature is too high.Commercial Refrigerator
dDry cooling is activated.Commercial Refrigerator
dAThe door alarm was activated.Close the door.Commercial Refrigerator
E01Sensor warningCall authorized service for assistance as soon as possible.Commercial Refrigerator
E02Sensor warningCall authorized service for assistance as soon as possible.Commercial Refrigerator
E03Sensor warningCall authorized service for assistance as soon as possible.Commercial Refrigerator
E06Sensor warningCall authorized service for assistance as soon as possible.Commercial Refrigerator
E07Sensor warningCall authorized service for assistance as soon as possible.Commercial Refrigerator
E08Low voltage warningWait for voltage recovery; contact authorized service if the warning continues.Commercial Refrigerator
E1The room temperature sensor is defective.Monitor the temperature and request service immediately.Commercial Refrigerator
E1Defective room temperature sensor.Monitor the temperature and request service immediately.Commercial Refrigerator
E1Defective room sensor.Monitor temperature, then request service assistance immediately.Commercial Refrigerator
E2The evaporator sensor is defective.Request service assistance; defrosting becomes time based.Commercial Refrigerator
E2Defective evaporator sensor.Expect time-based defrosting and request service assistance.Commercial Refrigerator, Commercial Refrigerator
E10Refrigerator compartment is not cold enoughLower temperature or enable super cooling; keep doors closed and contact service if persistent.Commercial Refrigerator
E11Refrigerator compartment is too coldCheck super cooling, increase the temperature, and contact authorized service if persistent.Commercial Refrigerator
F1The room temperature sensor is defective.Have the service department replace the sensor.Commercial Refrigerator, Commercial Refrigerator
F1The room temperature sensor has failed.Request service assistance.Commercial Refrigerator
F1Room sensor error.Commercial Refrigerator, Commercial Refrigerator, Commercial Refrigerator
F1Cabinet temperature sensor is defective.Request service assistance.Commercial Refrigerator
F1Room temperature sensor failure.Service assistance is required.Commercial Refrigerator
F1Room temperature sensor is faulty, affecting temperature stability.Have the sensor replaced by service.Commercial Refrigerator
F1The cabinet sensor has failed.Request service assistance.765041500GB
F2The evaporator sensor is defective or the evaporator is heavily iced.Defrost completely for 24 hours; contact service if the fault remains.Commercial Refrigerator
F2The evaporator temperature sensor has failed.Request service assistance.Commercial Refrigerator
F2Evaporator sensor error.Commercial Refrigerator, Commercial Refrigerator, Commercial Refrigerator
F2Evaporator temperature sensor has problems.Have the sensor replaced and request service assistance.Commercial Refrigerator
F2Evaporator sensor failure.Service assistance is required.Commercial Refrigerator
F2Evaporator sensor is faulty.Have the sensor replaced by service as soon as possible.Commercial Refrigerator
F2The evaporator sensor is defective.Have service replace the sensor as soon as possible.Commercial Refrigerator
F2The evaporator sensor has failed.Request service assistance.765041500GB
F3The condensation sensor has a problem.Have the sensor replaced as soon as possible.Commercial Refrigerator
F3Condenser sensor 1 error.Commercial Refrigerator, Commercial Refrigerator, Commercial Refrigerator
F3Condenser temperature sensor has problems.Have the sensor replaced and request service assistance.Commercial Refrigerator
F3Condenser sensor 1 failure.Service assistance is required.Commercial Refrigerator
F3Condenser sensor is faulty.Have the sensor replaced by service.Commercial Refrigerator
F3The condenser sensor or terminating resistor is defective.Have service replace it promptly.Commercial Refrigerator
F3*Condenser sensor 1 has failed.Request service assistance.Commercial Refrigerator, 765041500GB
F4The second condensation sensor has failed.Follow the F3 fault procedure and have the sensor replaced.Commercial Refrigerator
F4Condenser sensor 2 error.Commercial Refrigerator, Commercial Refrigerator, Commercial Refrigerator
F4Condenser sensor 2 failure.Service assistance is required.Commercial Refrigerator
F4*Condenser sensor 2 has failed.Request service assistance.Commercial Refrigerator, 765041500GB
F5The PCL hard chill temperature sensor has failed.Contact the service department to replace the sensor.Commercial Refrigerator
F7The condenser is overheating or undercooling.Commercial Refrigerator
F7Overheated condenser sensors 1 and 2.Commercial Refrigerator
F7Condenser 1 and 2 are overheated.Commercial Refrigerator, Commercial Refrigerator
F7Condenser temperature is too high.Check ventilation and condenser cleanliness; relocate the cabinet or request service if needed.Commercial Refrigerator, Commercial Refrigerator
F7The condenser temperature is too high.Disconnect power, clean the condenser or filter, and contact service if unresolved.Commercial Refrigerator
F7*The condenser temperature is too high.Check for a clogged condenser or excessive ambient heat. Improve ventilation; request service if unresolved.Commercial Refrigerator, 765041500GB
FILTERThe condenser air filter needs cleaning.Clean the filter, then reset the controller using the specified key combination.Commercial Refrigerator, Commercial Refrigerator
FILTERCondenser air filter cleaning is due.Clean the air filter, then use the specified key combination to reset the alarm.Commercial Refrigerator
OPThe door is open, or has been open over two minutes.Close the door.Commercial Refrigerator
OPThe door is open.Close the door.Commercial Refrigerator, Commercial Refrigerator, Commercial Refrigerator
OPDoor is open, or has been open over two minutes.Close the door.Commercial Refrigerator
OPDoor is open, or has remained open over two minutes.Close the door.Commercial Refrigerator
Pr1Room sensor error.Commercial Refrigerator
∟dDoor alarm.Commercial Refrigerator