Gram error codes
39 Gram error and alarm codes from 15 manuals: what each code means and what the manual says to do.
39 codes15 manuals
Codes and what they mean
As described in each manual. The same code can mean different things on different models, so check the model column.
| Code | Meaning | What to do | Manual |
|---|---|---|---|
| -0- | Overheated condenser. | Commercial Refrigerator | |
| -0- | Condenser 1 and 2 are overheated. | Commercial Refrigerator, Commercial Refrigerator | |
| -oA1 | The door is open. | Commercial Refrigerator, 765041500GB | |
| A0 | Current or ongoing temperature alarm. | A current alarm cannot be reset or deleted. | Commercial Refrigerator |
| A0 | Present or ongoing temperature alarm. | It cannot be reset or deleted while present. | Commercial Refrigerator |
| A1 | The door alarm was activated. | Close the door, then press the button to delete the alarm. | Commercial Refrigerator |
| A1 | Alarm triggered after the door remains open too long. | Commercial Refrigerator, Commercial Refrigerator | |
| A1 | Alarm triggered by a door left open too long. | Commercial Refrigerator | |
| A1 | The local door alarm is active. | 765041500GB | |
| A1 / OP | The door remains open or is not closed correctly. | Press P to confirm the alarm. | Commercial Refrigerator, Commercial Refrigerator |
| A1..A10 | Logged temperature alarms that are no longer present. | Review alarms, then verify them or hold five seconds to delete them. | Commercial Refrigerator |
| A2 | The local maximum temperature alarm was activated. | Wait until temperature is below the maximum, then press the button. | Commercial Refrigerator |
| A2 | The cabinet has a high internal temperature. | Press P to confirm the alarm. | Commercial Refrigerator |
| A2 | Local high temperature alarm. | Press P to acknowledge the alarm. | Commercial Refrigerator |
| A2 | Local upper limit alarm has been or is currently activated. | Press P to acknowledge the alarm. | Commercial Refrigerator |
| A2 | The door alarm was activated. | Press P to acknowledge the alarm. | Commercial Refrigerator |
| A2 | The upper alarm limit has been reached. | 765041500GB | |
| A3 | The external upper alarm limit has been reached. | 765041500GB | |
| A4 | The cabinet has a high external temperature. | Press P to confirm the alarm. | Commercial Refrigerator |
| A4 | External high temperature alarm. | Press P to acknowledge the alarm. | Commercial Refrigerator |
| A4 | External upper limit alarm has been or is currently activated. | Press P to acknowledge the alarm. | Commercial Refrigerator |
| A4 | The local maximum temperature alarm was activated. | Press P to acknowledge the alarm. | Commercial Refrigerator |
| A4 | The lower alarm limit has been reached. | 765041500GB | |
| A5 | External lower limit alarm has been activated. | Press P to acknowledge the alarm. | Commercial Refrigerator |
| A5 | The external minimum temperature alarm was activated. | Press P to acknowledge the alarm. | Commercial Refrigerator |
| Ah | High temperature alarm. | Commercial Refrigerator, Commercial Refrigerator, Commercial Refrigerator | |
| AL | Low temperature alarm. | Commercial Refrigerator, Commercial Refrigerator, Commercial Refrigerator | |
| COH | Condenser temperature is too high. | Commercial Refrigerator | |
| CSd | Compressor blocked because condenser temperature is too high. | Commercial Refrigerator | |
| d | Dry cooling is activated. | Commercial Refrigerator | |
| dA | The door alarm was activated. | Close the door. | Commercial Refrigerator |
| E01 | Sensor warning | Call authorized service for assistance as soon as possible. | Commercial Refrigerator |
| E02 | Sensor warning | Call authorized service for assistance as soon as possible. | Commercial Refrigerator |
| E03 | Sensor warning | Call authorized service for assistance as soon as possible. | Commercial Refrigerator |
| E06 | Sensor warning | Call authorized service for assistance as soon as possible. | Commercial Refrigerator |
| E07 | Sensor warning | Call authorized service for assistance as soon as possible. | Commercial Refrigerator |
| E08 | Low voltage warning | Wait for voltage recovery; contact authorized service if the warning continues. | Commercial Refrigerator |
| E1 | The room temperature sensor is defective. | Monitor the temperature and request service immediately. | Commercial Refrigerator |
| E1 | Defective room temperature sensor. | Monitor the temperature and request service immediately. | Commercial Refrigerator |
| E1 | Defective room sensor. | Monitor temperature, then request service assistance immediately. | Commercial Refrigerator |
| E2 | The evaporator sensor is defective. | Request service assistance; defrosting becomes time based. | Commercial Refrigerator |
| E2 | Defective evaporator sensor. | Expect time-based defrosting and request service assistance. | Commercial Refrigerator, Commercial Refrigerator |
| E10 | Refrigerator compartment is not cold enough | Lower temperature or enable super cooling; keep doors closed and contact service if persistent. | Commercial Refrigerator |
| E11 | Refrigerator compartment is too cold | Check super cooling, increase the temperature, and contact authorized service if persistent. | Commercial Refrigerator |
| F1 | The room temperature sensor is defective. | Have the service department replace the sensor. | Commercial Refrigerator, Commercial Refrigerator |
| F1 | The room temperature sensor has failed. | Request service assistance. | Commercial Refrigerator |
| F1 | Room sensor error. | Commercial Refrigerator, Commercial Refrigerator, Commercial Refrigerator | |
| F1 | Cabinet temperature sensor is defective. | Request service assistance. | Commercial Refrigerator |
| F1 | Room temperature sensor failure. | Service assistance is required. | Commercial Refrigerator |
| F1 | Room temperature sensor is faulty, affecting temperature stability. | Have the sensor replaced by service. | Commercial Refrigerator |
| F1 | The cabinet sensor has failed. | Request service assistance. | 765041500GB |
| F2 | The evaporator sensor is defective or the evaporator is heavily iced. | Defrost completely for 24 hours; contact service if the fault remains. | Commercial Refrigerator |
| F2 | The evaporator temperature sensor has failed. | Request service assistance. | Commercial Refrigerator |
| F2 | Evaporator sensor error. | Commercial Refrigerator, Commercial Refrigerator, Commercial Refrigerator | |
| F2 | Evaporator temperature sensor has problems. | Have the sensor replaced and request service assistance. | Commercial Refrigerator |
| F2 | Evaporator sensor failure. | Service assistance is required. | Commercial Refrigerator |
| F2 | Evaporator sensor is faulty. | Have the sensor replaced by service as soon as possible. | Commercial Refrigerator |
| F2 | The evaporator sensor is defective. | Have service replace the sensor as soon as possible. | Commercial Refrigerator |
| F2 | The evaporator sensor has failed. | Request service assistance. | 765041500GB |
| F3 | The condensation sensor has a problem. | Have the sensor replaced as soon as possible. | Commercial Refrigerator |
| F3 | Condenser sensor 1 error. | Commercial Refrigerator, Commercial Refrigerator, Commercial Refrigerator | |
| F3 | Condenser temperature sensor has problems. | Have the sensor replaced and request service assistance. | Commercial Refrigerator |
| F3 | Condenser sensor 1 failure. | Service assistance is required. | Commercial Refrigerator |
| F3 | Condenser sensor is faulty. | Have the sensor replaced by service. | Commercial Refrigerator |
| F3 | The condenser sensor or terminating resistor is defective. | Have service replace it promptly. | Commercial Refrigerator |
| F3* | Condenser sensor 1 has failed. | Request service assistance. | Commercial Refrigerator, 765041500GB |
| F4 | The second condensation sensor has failed. | Follow the F3 fault procedure and have the sensor replaced. | Commercial Refrigerator |
| F4 | Condenser sensor 2 error. | Commercial Refrigerator, Commercial Refrigerator, Commercial Refrigerator | |
| F4 | Condenser sensor 2 failure. | Service assistance is required. | Commercial Refrigerator |
| F4* | Condenser sensor 2 has failed. | Request service assistance. | Commercial Refrigerator, 765041500GB |
| F5 | The PCL hard chill temperature sensor has failed. | Contact the service department to replace the sensor. | Commercial Refrigerator |
| F7 | The condenser is overheating or undercooling. | Commercial Refrigerator | |
| F7 | Overheated condenser sensors 1 and 2. | Commercial Refrigerator | |
| F7 | Condenser 1 and 2 are overheated. | Commercial Refrigerator, Commercial Refrigerator | |
| F7 | Condenser temperature is too high. | Check ventilation and condenser cleanliness; relocate the cabinet or request service if needed. | Commercial Refrigerator, Commercial Refrigerator |
| F7 | The condenser temperature is too high. | Disconnect power, clean the condenser or filter, and contact service if unresolved. | Commercial Refrigerator |
| F7* | The condenser temperature is too high. | Check for a clogged condenser or excessive ambient heat. Improve ventilation; request service if unresolved. | Commercial Refrigerator, 765041500GB |
| FILTER | The condenser air filter needs cleaning. | Clean the filter, then reset the controller using the specified key combination. | Commercial Refrigerator, Commercial Refrigerator |
| FILTER | Condenser air filter cleaning is due. | Clean the air filter, then use the specified key combination to reset the alarm. | Commercial Refrigerator |
| OP | The door is open, or has been open over two minutes. | Close the door. | Commercial Refrigerator |
| OP | The door is open. | Close the door. | Commercial Refrigerator, Commercial Refrigerator, Commercial Refrigerator |
| OP | Door is open, or has been open over two minutes. | Close the door. | Commercial Refrigerator |
| OP | Door is open, or has remained open over two minutes. | Close the door. | Commercial Refrigerator |
| Pr1 | Room sensor error. | Commercial Refrigerator | |
| ∟d | Door alarm. | Commercial Refrigerator |