Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Wait before useat least 2 hourscabinet transported in horizontal positionp. 32
Clearance above30 mm (1.2 in)All cabinetsTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 35
DefrostautomaticF/FG 210/410p. 42
Room temperature rangeup to +35 °C (95 °F)ambient temperature during operationTypical for commercial refrigeration: 60 to 100 °F (16 to 38 °C)p. 33

Gram Commercial Refrigerator questions

Answers taken from this manual. Each one links to the page it comes from.

When does the controller save a temperature setting automatically?

After 15 seconds without button presses, the controller returns to temperature display and saves the setting automatically.

Manual: page 41

How much space must I leave above the cabinet?

Leave at least 30 mm of clearance above the cabinet, with free air circulation beneath, above and behind it.

Other brands: Other 12" (30.5 cm) · Summit 4“(102mm) · True 1" (25.4 mm) Compare all

Manual: page 35

Does a glass-door cabinet need to be fastened?

Yes. Fasten it to a stable surface with the supplied brackets because it can tilt when the door is open.

Manual: page 34

How do K/KG and F/FG cabinets defrost automatically?

Both cabinet groups defrost automatically 4 times every 24 hours.

ModelsMethodSchedule
K/KG 210/410Air circulation during compressor standstill4 times every 24 hours
F/FG 210/410Heating element at the evaporator4 times every 24 hours

Manual: page 42

When might manual defrosting be needed?

Frequent door opening and replenishment can require manual defrosting under severe load. Do not use sharp or pointed objects to speed defrosting.

Manual: page 42

How long should I wait before turning the appliance on again?

Wait minimum 3 minutes before switching it on again to protect the compressor.

Manual: page 38

What should I do with the front-panel vent holes?

Keep the front-panel vent holes unblocked during use.

Manual: page 38

How long should a horizontally transported cabinet stand before startup?

At least 2 hours before startup, allowing compressor oil to run back.

Manual: page 32

How do I set up the cabinet for use?
  1. Choose a dry, ventilated room away from sunlight and heat-emitting surfaces.
  2. Keep the ambient temperature at or below +35 °C.
  3. Avoid chlorine- or acid-containing environments.
  4. Remove protective film from the cabinet and interior parts.
  5. Clean the cabinet with a mild soap solution.
  6. Place the cabinet on a level, horizontal floor.
  7. For legs, adjust them until the cabinet stands level and upright.
  8. For castors, lock both front castors after positioning, and avoid frames.

Manual: page 33

Gram Commercial Refrigerator compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Gram Commercial RefrigeratorOther Commercial RefrigeratorSummit FF64BCSSBeverage-Air FLG
Wait before useat least 2 hoursat least 24 hoursabout 2 hours3 hours
Clearance above30 mm (1.2 in)12" (30.5 cm)4” (102mm)0 in
Room temperature rangeup to +35 °C (95 °F)below 90 °F (32 °C)above 44 °F (7 °C) and below 90 °F (32 °C)60º F to 100º F

Similar Gram commercial refrigeration

Gram IO-REF-1455Instruction Manual132 pages
Gram Commercial Refrigeration Instruction ManualInstruction Manual131 pages
Gram COMPACT 600 Gram RefrigeratorUser Manual124 pages
Gram IO-REF-1453Instruction Manual124 pages
Gram IO-REF-1421Instruction Manual120 pages
Gram IO-REF-1419Operating Instructions120 pages
Gram 6C1854Operating Instructions120 pages
Gram Compact F220 User ManualUser Manual118 pages
All Gram commercial refrigeration →