| Time to cool down | 6 hoursBefore placing product in the case after startupTypical for commercial refrigeration: 1 to 24 hours | p. 7 |
|---|---|---|
| Clearance above | 10”Minimum air space above the cabinetTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm) | p. 7 |
| Clearance at the sides | 0”Minimum air space at each sideTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm) | p. 7 |
| Clearance behind | 6” needs more space than mostMinimum air space at the rearTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm) | p. 7 |
Master-Bilt Commercial Refrigerator questions
Answers taken from this manual. Each one links to the page it comes from.
How do I set the case temperature?
Set the temperature control for the desired temperature range.
Manual: page 8
When can I load product after starting the case?
Where should I place the Master-Bilt case?
Place it in an air-conditioned store at or below 75 °F and 55% relative humidity or less, away from sun, radiant heat, and nearby airflow. Leave 6” behind it against a wall and 10” above the cabinet.
Manual: page 4
How do I route the case drain?
Use the included P-trap and route the drain tubing into the condensate pan.
- Install the included P-trap on the case drain.
- Check that the drain tubing is trapped and enters the condensate pan.
Manual: page 4
What should I do if my shipment arrives damaged?
Inspect the shipment on arrival, then act promptly if unpacking reveals concealed damage.
- Inspect all cartons and crates when they arrive.
- Record damage or shortages on every bill of lading copy before signing.
- Call the delivering truck line immediately if damage appears after unpacking.
- Submit a written report, request immediate inspection, and retain the crating material.
Manual: page 6
What should I provide when selling or giving away the cabinet?
Give the buyer every safety label and the Installation Service Manual with the cabinet. Contact Master-Bilt customer service during the transfer or disposal so its new location can be recorded.
Manual: page 12
Master-Bilt Commercial Refrigerator compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Master-Bilt Commercial Refrigerator | True T-23-HC | EdgeStar VBM101SS | Koolmore KM-FMD12SGD | |
|---|---|---|---|---|
| Time to cool down | 6 hours | 24 hours | at least 24 hours | about 1 hour |
| Clearance above | 10” | 0" (0 mm) | 1/2” | over 4 inches (10.2 cm) |
| Clearance at the sides | 0” | 0" (0 mm) | 1/2” | at least 4 inches (10.2 cm) |
| Clearance behind | 6” | 1" (25.4 mm) | 3/4” | 3 inches (7.6 cm) |
Similar Master-Bilt commercial refrigeration
| Master-Bilt Commercial Refrigeration Instruction Manual | Instruction Manual | 18 pages |
|---|---|---|
| Master-Bilt GT-30 | Instruction Manual | 16 pages |
| Master-Bilt GT-50 | Instruction Manual | 15 pages |
| Master-Bilt TEL-2-30 | User Manual | 6 pages |
| Master-Bilt MCR-33-101 | User Manual | 6 pages |
| Master-Bilt BEL-3-24 | User Manual | 6 pages |