Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Recommended fridge temperature+35 Fmedium temperature (MT) applicationTypical for commercial refrigeration: 32 to 40 °F (0 to 4 °C)p. 9
Recommended freezer temperature, 10 °F (-12 °C)low temperature (LT) applicationp. 9
Time to cool downat least 6 hoursbefore putting product in the case after startupTypical for commercial refrigeration: 1 to 24 hoursp. 7
Clearance above4”To comply with UL requirementsTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 6
Clearance at the sides0”To comply with UL requirementsTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 6
Clearance behind4”For proper condensing unit air circulation6”TOP MOUNT cabinets with the condensate pan installedTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 6 p. 8
DefrostELECfactory settingp. 10

Master-Bilt Commercial Refrigerator questions

Answers taken from this manual. Each one links to the page it comes from.

What does the High Temperature Alarm mean?

The temperature has exceeded the high alarm setpoint.

Manual: page 12

What happens if I switch the temperature display between C and F?

Reprogram every temperature-related parameter after switching; the unit does not convert them automatically.

Manual: page 12

What minimum clearances does the cabinet need around it?

Use the clearance that matches your installation condition.

LocationMinimum clearanceCondition
Top4”Proper condensing-unit air circulation
Back4”Proper condensing-unit air circulation
Top4”UL requirements
Rear6”UL requirements
Each side0”UL requirements
Wall6”TOP MOUNT condensate pan

Manual: page 6, page 8

How should I position the cabinet for proper drainage and door operation?
  1. Slide the cabinet into its location.
  2. Level it side-to-side and front-to-back for coil-pan drainage and self-closing doors.

Manual: page 6

How do I start a manual defrost?

Hold MAN DEF for 3 seconds to start a manual defrost.

Manual: page 9

How do I schedule one defrost daily at 11:59 PM?
  1. Hold SET and DOWN for 10 seconds until dSPL appears.
  2. Press DOWN five times to reach Defrost Interval (dFIn).
  3. Press SET, select tdAy with DOWN, then press SET.
  4. Press DOWN seven times to reach Number of Defrosts (noDF).
  5. Press SET, choose 1 with UP or DOWN, then press SET.
  6. Press DOWN to Defrost Start Time (dEF1), then press SET.
  7. Choose 11:59 PM with UP or DOWN, then press SET.
  8. Press DOWN ten times to exit programming.

Manual: page 10, page 12

Why is the unit vibrating or rubbing?

Vibrating or rubbing tubing can cause the noise; dampen and clamp the tubing.

Manual: page 13

What should I do before replacing a burned-out fluorescent tube?

Turn off power to the lighting circuit first, and have a qualified technician service electrical components.

Manual: page 7

How do I reset Er 1 through Er 7?
  • Er 1, Er 2, or Er 5: Cut power and correct the problem to reset the display.
  • Er 3 or Er 4: Press UP or DOWN; if it remains, the sensor must be replaced.
  • Er 6 or Er 7: The message resets automatically after temperature returns within both set points.

Manual: page 12

Error codes in this manual

CodeMeaningWhat to do
ALHiHigh temperature alarm setpoint triggers the alarm and display message.p. 12
Er 1ERC software or hardware failure.Cut power, correct the problem, then restore power to reset the display.p. 12
Er 2ERC communication failure involving the display module cable.Cut power, correct the problem, then restore power to reset the display.p. 12
Er 3Zone temperature sensor is open or shorted.Press UP or DOWN to reset it; replace the sensor if the message remains.p. 12
Er 4Evaporator sensor is open or shorted.Press UP or DOWN to reset it; replace the sensor if the message remains.p. 12
Er 5ERC software or hardware failure.Cut power, correct the problem, then restore power to reset the display.p. 12
Er 6Temperature has fallen below the low alarm setpoint.The error resets automatically when temperature returns within both setpoints.p. 12
Er 7Temperature has risen above the high alarm setpoint.The error resets automatically when temperature returns within both setpoints.p. 12
Er 8Relay and display modules are incompatible.p. 12
All Master-Bilt error codes →

Master-Bilt Commercial Refrigerator compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Master-Bilt Commercial RefrigeratorOther Commercial RefrigeratorTrue TBB-1-HCEdgeStar VBM101SS
Recommended fridge temperature+35 F+4 C··
Recommended freezer temperature, 10 °F (-12 °C)···
Time to cool downat least 6 hours5-6 hours24 hoursat least 24 hours
Clearance above4”·1" (25.4 mm)1/2”
Clearance at the sides0”100 mm (4”) (3.9 in)1" (25.4 mm)1/2”
Clearance behind4”50mm (2”)1" (25.4 mm)3/4”

Similar Master-Bilt commercial refrigeration

Master-Bilt GT-30Instruction Manual16 pages
Master-Bilt Commercial Refrigeration Instruction ManualInstruction Manual16 pages
Master-Bilt GT-50Instruction Manual15 pages
Master-Bilt TEL-2-30User Manual6 pages
Master-Bilt MCR-33-101User Manual6 pages
Master-Bilt BEL-3-24User Manual6 pages
All Master-Bilt commercial refrigeration →