Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Fridge adjustment range34 to 38 °F (1 to 3 °C)Factory setting for refrigeratorsTypical for commercial refrigeration: 34 to 45 °F (1 to 7 °C)p. 6
Wait before useat least 24 hoursafter laying the unit on its side or backp. 5
Clearance above12" (30.5 cm)above the unitTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 5
Clearance at the sides2" (5.1 cm)from any wallTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 5

Maxx Cold Commercial Refrigerator questions

Answers taken from this manual. Each one links to the page it comes from.

What factory temperature range is set for refrigerators?

34 to 38 °F is the factory temperature range for refrigerators.

Other brands: Other 32 °F (0 °C) to 41 °F (5 °C) · Liebherr b1 to b9 · Summit 36 °F/2 °C to 43 °F/6 °C Compare all

Manual: page 6

How do I view the target temperature?

Press SET to display the target set point.

Manual: page 7

What clearance does the unit need around its cabinet?

At least 2" from any wall and 12" above the unit are specified.

LocationMinimum clearance
Any wall2"
Above unit12"

Manual: page 5

How long should I wait before starting the unit after laying it down?

Wait at least 24 hours before startup after laying the unit on its side or back.

Other brands: Other 24 hours · Summit about 2 hours · True 24 hours Compare all

Manual: page 5

How do I clean the door gasket?
  1. Clean the gasket regularly with warm, soapy water.
  2. Avoid full-strength cleaning products, which can make the gasket brittle.
  3. Do not use sharp tools or knives on the gasket.

Manual: page 10

How do I replace the door gasket?
  1. Pull the old gasket out of the door groove.
  2. Press the replacement gasket into the groove by hand.

Manual: page 10

How does automatic defrosting work in refrigerators and freezers?

Every 6 hours, defrosting pauses operation until the coil reaches its restart temperature or 20 minutes pass.

TypeDefrost cycleRestart condition
RefrigeratorUnit shuts off every 6 hours41 °F or 20 minutes
FreezerUnit off, electric heater on every 6 hours45 °F or 20 minutes

Manual: page 6

How do I start a manual defrost?

Press (DEF) to start a manual defrost.

Manual: page 7

How do I reset a recorded temperature alarm?
  1. Press UP or DOWN to display the alarm signal.
  2. Hold SET until rst appears.
  3. Press SET again; when rst blinks, normal temperature returns.

Manual: page 8

How do I shut down the unit before cleaning?
  1. Turn the On/Off Switch to OFF.
  2. Disconnect the unit from the power source before cleaning.

Manual: page 8

Where can I find the refrigerator or freezer serial number?

Look inside the unit on the upper-left wall, and have the number ready for parts or service.

Manual: page 3

Maxx Cold Commercial Refrigerator compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Maxx Cold Commercial RefrigeratorOther Commercial RefrigeratorSummit FF64BCSSPolar UA001-A
Fridge adjustment range34 to 38 °F (1 to 3 °C)34 °F to 38 °F (1 °C, 3 °C)36 °F to 43 °F (2 °C, 6 °C)-2 °C to +4 °C (28 °F, 39 °F)
Wait before useat least 24 hoursat least 24 hoursabout 2 hoursabout 12 hours
Clearance above12" (30.5 cm)12" (30.5 cm)4” (102mm)5cm
Clearance at the sides2" (5.1 cm)2" (5.1 cm)5” (127mm)2.5cm

Similar Maxx Cold commercial refrigeration

Maxx Cold MXM1-23RBHCUser Manual32 pages
Maxx Cold MXCR-23FDHCUser Manual16 pages
Maxx Cold MXCR27UHCUser Manual14 pages
Maxx Cold MCR-72FDHCUser Manual12 pages
Maxx Cold MCF-23FDHCUser Manual11 pages
Maxx Cold MCFT-23FDHCUser Manual8 pages
All Maxx Cold commercial refrigeration →