Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Recommended fridge temperature | 3-4normal cooler useTypical for commercial refrigeration: 32 to 40 °F (0 to 4 °C) | p. 9 |
|---|---|---|
| Time to cool down | about two hoursinitial operation before storing foodTypical for commercial refrigeration: 1 to 24 hours | p. 9 |
| Clearance behind | 10 cm at least (3.9 in)Distance from the wallTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm) | p. 5 |
| Room temperature range | not higher than 40℃ambient temperatureTypical for commercial refrigeration: 60 to 100 °F (16 to 38 °C) | p. 6 |
Premium Levella PRF1257DX questions
Answers taken from this manual. Each one links to the page it comes from.
How do I adjust the cooler’s temperature?
Turn the temperature control knob clockwise for colder settings; a larger number lowers the temperature. Use position 3-4 normally; position 6 makes the cooler operate continuously.
Manual: page 9
How long should the cooler run empty before I add food?
Run the cooler empty for about two hours before storing food.
Manual: page 9
How much space should I leave behind the cooler?
Leave at least 10 cm from the wall, and level the unit.
Other brands: Other 4” · Summit 5” (127mm) · True 1" (25.4 mm) Compare all
Manual: page 5
What are the cabinet dimensions for each model?
The cabinet dimensions depend on the model.
| Model | Dimensions (W×D×H/mm) |
|---|---|
| PRF65DX / PRF657DX | 575×540×1645 |
| PRF90DX / PRF907DX | 575×610×1710 |
| PRF125DX / PRF1257DX | 615×610×1990 |
| PRF155DX / PRF1557DX | 655×705×1990 |
Manual: page 7
Is a refrigerant-flow sound normal?
Yes, refrigerant flowing inside the cooler is listed as a common phenomenon.
Manual: page 11
How do I level the cooler?
Use the adjustable feet and a spirit level, then set the specified tilt for closing and drainage.
- Set the unit in its selected location.
- Place a spirit level on a shelf and check the unit in both directions.
- Adjust the feet until the unit is level during operation.
- Set a 2° tilt to support door closing and condensate drainage.
Premium Levella PRF1257DX compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Premium Levella PRF1257DX | Other Commercial Refrigerator | Summit FF64BCSS | True T-23-HC | |
|---|---|---|---|---|
| Recommended fridge temperature | 3-4 | +4 C | · | · |
| Clearance behind | 10 cm at least (3.9 in) | 50mm (2”) | 5” (127mm) | 1" (25.4 mm) |
| Room temperature range | not higher than 40℃ | · | above 44 °F (7 °C) and below 90 °F (32 °C) | not less than 60 °F (15.5 °C) |