Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Recommended fridge temperature3-4normal cooler useTypical for commercial refrigeration: 32 to 40 °F (0 to 4 °C)p. 9
Time to cool downabout two hoursinitial operation before storing foodTypical for commercial refrigeration: 1 to 24 hoursp. 9
Clearance behind10 cm at least (3.9 in)Distance from the wallTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 5
Room temperature rangenot higher than 40℃ambient temperatureTypical for commercial refrigeration: 60 to 100 °F (16 to 38 °C)p. 6

Premium Levella PRF1257DX questions

Answers taken from this manual. Each one links to the page it comes from.

How do I adjust the cooler’s temperature?

Turn the temperature control knob clockwise for colder settings; a larger number lowers the temperature. Use position 3-4 normally; position 6 makes the cooler operate continuously.

Manual: page 9

How long should the cooler run empty before I add food?

Run the cooler empty for about two hours before storing food.

Manual: page 9

How much space should I leave behind the cooler?

Leave at least 10 cm from the wall, and level the unit.

Other brands: Other 4” · Summit 5” (127mm) · True 1" (25.4 mm) Compare all

Manual: page 5

What are the cabinet dimensions for each model?

The cabinet dimensions depend on the model.

ModelDimensions (W×D×H/mm)
PRF65DX / PRF657DX575×540×1645
PRF90DX / PRF907DX575×610×1710
PRF125DX / PRF1257DX615×610×1990
PRF155DX / PRF1557DX655×705×1990

Manual: page 7

Is a refrigerant-flow sound normal?

Yes, refrigerant flowing inside the cooler is listed as a common phenomenon.

Manual: page 11

How do I level the cooler?

Use the adjustable feet and a spirit level, then set the specified tilt for closing and drainage.

  1. Set the unit in its selected location.
  2. Place a spirit level on a shelf and check the unit in both directions.
  3. Adjust the feet until the unit is level during operation.
  4. Set a 2° tilt to support door closing and condensate drainage.

Manual: page 5, page 6

Premium Levella PRF1257DX compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Premium Levella PRF1257DXOther Commercial RefrigeratorSummit FF64BCSSTrue T-23-HC
Recommended fridge temperature3-4+4 C··
Clearance behind10 cm at least (3.9 in)50mm (2”)5” (127mm)1" (25.4 mm)
Room temperature rangenot higher than 40℃·above 44 °F (7 °C) and below 90 °F (32 °C)not less than 60 °F (15.5 °C)