Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Clearance above1”Minimum clearance above the unit for proper airflowTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 4
Clearance at the sidesThere are no clearance requirementsSidesno clearance requirementsC Series compact modelsTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 4
Clearance behindThere are no clearance requirements needs less space than mostRearno clearance requirementsC Series compact modelsTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 4
Space to open the doors120°; 90° minimum120° door stay-open feature; doors must open at least 90° for maximum clear widthp. 3
DefrostOff-Cyclerefrigeratorsautomaticfreezersp. 6

Traulsen CLUC-27F-SD questions

Answers taken from this manual. Each one links to the page it comes from.

What clearances and door openings does this Traulsen unit require?

Minimum clearances and door openings are listed below.

Location or featureRequirement
Above unitMinimum 1” clearance
Sides and rearNo clearance requirement
Door openingAt least 90°
Door stay-open featureOperates at 120°

Manual: page 3, page 4

Do I need to manually defrost this refrigerator or freezer?

No. Refrigerators and freezers defrost automatically; the control also provides a manual-defrost option if needed.

Manual: page 5

What does dEF mean on a freezer?

It indicates a freezer defrost cycle, during which the compressor and evaporator fans are off. The cycle may occur 3 to 8 times within each 24-hour period, depending on door openings and ambient conditions.

Manual: page 6

What do the second parameter group modes do?

The IISM setting determines how the controller switches to the second parameter group.

  • NON disables use of the second parameter group.
  • MAN lets the button switch between parameter groups.
  • ECO switches automatically when ECO conditions are detected.
  • DI switches when the DIx input is on.

Manual: page 12

What does the SB setting mean?

SB controls whether the Stand-by button is enabled.

Manual: page 13

How do I prepare the refrigerator for an extended shutdown?
  1. Disconnect the electrical power supply and open the doors.
  2. Wait until the cabinet reaches room temperature, then wipe the interior dry.
  3. Leave the doors open and check again for collected moisture.
  4. Restart it using the prestart and operation instructions.

Manual: page 9

What does LOC = YES do on the controller?

LOC = YES disables all button functions; change it to LOC = NO to restore normal keypad operation.

Manual: page 9

Why is the refrigerator slow to return to its normal temperature?
  • Warm food or a heavy load. Allow recovery time; leave space for airflow and avoid overloading.
  • Frequent door or drawer opening. Wait for the cabinet to recover after access.

Manual: page 6

What happens during a refrigerator defrost cycle?

It melts frost from the evaporator coil; the Off-Cycle process can last up to 50 minutes.

Manual: page 6

Traulsen CLUC-27F-SD compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Traulsen CLUC-27F-SDEdgeStar VBM101SSHoshizaki Commercial Refrigerator
Clearance above1”1/2”30 cm (11.8 in)
Space to open the doors120°; 90° minimum2 1/4”120 cm (47.2 in)

Similar Traulsen commercial refrigeration

Traulsen G10000Service Manual78 pages
Traulsen AHT126WPUT-FHGService Manual40 pages
Traulsen G13010Service Manual32 pages
Traulsen AHT126WPUT-FHGOwner's Manual26 pages
Traulsen G10000Owner's Manual24 pages
Traulsen TU044HTOwner's Manual24 pages
Traulsen G10000Owner's Manual20 pages
Traulsen G10000Service Manual20 pages
All Traulsen commercial refrigeration →