Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Fridge factory setting+2 °C (36 °F)HRWE / HRFWE chiller section+2HRWE / HRFWE chiller sectionTypical for commercial refrigeration: 35 to 38 °F (2 to 3 °C)p. 20
Fridge adjustment range-2 to +12 °C (28 to 54 °F)HRWE / HRFWE chiller section-2 to +12HRWE / HRFWE chiller sectionTypical for commercial refrigeration: 34 to 45 °F (1 to 7 °C)p. 20
Freezer factory setting-20 °C (-4 °F)HFWE freezer, HRFWE freezer and Combi-20HRFWE freezer sectionTypical for commercial refrigeration: -4 to 0 °F (-20 to -18 °C)p. 20
Freezer adjustment range-7 to -25 °C (19 to -13 °F)HFWE-16 to -23 °C (3 to -9 °F)HRFWE freezer sectionTypical for commercial refrigeration: -8 to 3 °F (-22 to -16 °C)p. 20
Time to cool down1 hourBefore putting foods into the cabinet after energizingTypical for commercial refrigeration: 1 to 24 hoursp. 19
Clearance above30 cm (11.8 in)from the ceiling to the top of the unitTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 12
Space to open the doors120 cm (47.2 in)at the front of the unit for smooth door operationp. 12
Defrostautomatic defrost cycleFreezer and refrigerator sectionsManual defrost cycleStarted by holding the defrost keyp. 21

Hoshizaki Commercial Refrigerator questions

Answers taken from this manual. Each one links to the page it comes from.

How do I change the cabinet temperature setting?
  1. Hold SET for more than 2 seconds.
  2. Press the up or down arrows within 10s.
  3. Press SET again, or wait 10s, to save the new setting.

Manual: page 20

What temperature settings can I use?

The adjustable ranges and factory settings are listed below.

Model or sectionRangeFactory setting
HFWE freezer-7 to -25 °C-20 °C
HRFWE freezer-16 to -23 °C-20 °C
HRWE / HRFWE chiller-2 to +12 °C+2 °C

Other brands: Other 32 °F (0 °C) to 41 °F (5 °C) · Liebherr b1 to b9 · Summit 36 °F/2 °C to 43 °F/6 °C Compare all

Manual: page 20

Why is frost forming inside the compartment?

High ambient humidity, frequent door opening, improperly closed doors, or food packed beyond the load line can cause frost inside.

Manual: page 22

How much clearance does the unit need above and in front?

Allow these minimum clearances for air circulation and door operation.

LocationMinimum clearance
Above unit30 cm
In front120 cm

Other brands: Other 12" (30.5 cm) · Summit 4“(102mm) · True 1" (25.4 mm) Compare all

Manual: page 12

Can I install the unit side-by-side or back-to-back?

Avoid locations where floor dripping is not permitted. Side-by-side or back-to-back installation can create condensation between units, causing water to fall onto the floor.

Manual: page 12

How do I clean the door gasket?

Clean the gasket and its contact surface thoroughly; food remnants can speed aging.

Manual: page 22

Why is condensation forming around the doors?

High ambient humidity or doors that are not closed properly can cause condensation around the doors.

Manual: page 22

Hoshizaki Commercial Refrigerator compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Hoshizaki Commercial RefrigeratorOther Commercial RefrigeratorSummit FF64BCSSTurbo Air TGM-10SD-N
Fridge factory setting+2 °C (36 °F)34 °F to 38 °F (1 °C, 3 °C)38 °F/3 °C37℉(3℃)
Fridge adjustment range-2 to +12 °C (28 to 54 °F)34 °F to 38 °F (1 °C, 3 °C)36 °F/2 °C to 43 °F/6 °CFrom '50℉' to '30℉'('10℃' to '-1℃')
Freezer factory setting-20 °C (-4 °F)-7°Fto -1 °F (-22 °C, -18 °C)0 °F/-18 °C-8℉(-22℃)
Freezer adjustment range-7 to -25 °C (19 to -13 °F)-7°Fto -1 °F (-22 °C, -18 °C)-11 °F/-24 °C to 11 °F/-12 °CFrom '5℉' to '-17℉'('-15℃' to '-27℃')
Time to cool down1 hour··24 hours
Clearance above30 cm (11.8 in)12" (30.5 cm)4“(102mm)·
Space to open the doors120 cm (47.2 in)···