Have a question about the Hoshizaki Commercial Refrigerator? The AI assistant looks through this manual and shows the pages with the answer.
Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Fridge factory setting | +2 °C (36 °F)HRWE / HRFWE chiller section+2HRWE / HRFWE chiller sectionTypical for commercial refrigeration: 35 to 38 °F (2 to 3 °C) | p. 20 |
|---|---|---|
| Fridge adjustment range | -2 to +12 °C (28 to 54 °F)HRWE / HRFWE chiller section-2 to +12HRWE / HRFWE chiller sectionTypical for commercial refrigeration: 34 to 45 °F (1 to 7 °C) | p. 20 |
| Freezer factory setting | -20 °C (-4 °F)HFWE freezer, HRFWE freezer and Combi-20HRFWE freezer sectionTypical for commercial refrigeration: -4 to 0 °F (-20 to -18 °C) | p. 20 |
| Freezer adjustment range | -7 to -25 °C (19 to -13 °F)HFWE-16 to -23 °C (3 to -9 °F)HRFWE freezer sectionTypical for commercial refrigeration: -8 to 3 °F (-22 to -16 °C) | p. 20 |
| Time to cool down | 1 hourBefore putting foods into the cabinet after energizingTypical for commercial refrigeration: 1 to 24 hours | p. 19 |
| Clearance above | 30 cm (11.8 in)from the ceiling to the top of the unitTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm) | p. 12 |
| Space to open the doors | 120 cm (47.2 in)at the front of the unit for smooth door operation | p. 12 |
| Defrost | automatic defrost cycleFreezer and refrigerator sectionsManual defrost cycleStarted by holding the defrost key | p. 21 |
Hoshizaki Commercial Refrigerator questions
Answers taken from this manual. Each one links to the page it comes from.
How do I change the cabinet temperature setting?
- Hold SET for more than 2 seconds.
- Press the up or down arrows within 10s.
- Press SET again, or wait 10s, to save the new setting.
Manual: page 20
What temperature settings can I use?
The adjustable ranges and factory settings are listed below.
| Model or section | Range | Factory setting |
|---|---|---|
| HFWE freezer | -7 to -25 °C | -20 °C |
| HRFWE freezer | -16 to -23 °C | -20 °C |
| HRWE / HRFWE chiller | -2 to +12 °C | +2 °C |
Other brands: Other 32 °F (0 °C) to 41 °F (5 °C) · Liebherr b1 to b9 · Summit 36 °F/2 °C to 43 °F/6 °C Compare all
Manual: page 20
Why is frost forming inside the compartment?
High ambient humidity, frequent door opening, improperly closed doors, or food packed beyond the load line can cause frost inside.
Manual: page 22
How much clearance does the unit need above and in front?
Allow these minimum clearances for air circulation and door operation.
| Location | Minimum clearance |
|---|---|
| Above unit | 30 cm |
| In front | 120 cm |
Other brands: Other 12" (30.5 cm) · Summit 4“(102mm) · True 1" (25.4 mm) Compare all
Manual: page 12
Can I install the unit side-by-side or back-to-back?
Avoid locations where floor dripping is not permitted. Side-by-side or back-to-back installation can create condensation between units, causing water to fall onto the floor.
Manual: page 12
How do I clean the door gasket?
Clean the gasket and its contact surface thoroughly; food remnants can speed aging.
Manual: page 22
Why is condensation forming around the doors?
High ambient humidity or doors that are not closed properly can cause condensation around the doors.
Manual: page 22
Hoshizaki Commercial Refrigerator compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Hoshizaki Commercial Refrigerator | Other Commercial Refrigerator | Summit FF64BCSS | Turbo Air TGM-10SD-N | |
|---|---|---|---|---|
| Fridge factory setting | +2 °C (36 °F) | 34 °F to 38 °F (1 °C, 3 °C) | 38 °F/3 °C | 37℉(3℃) |
| Fridge adjustment range | -2 to +12 °C (28 to 54 °F) | 34 °F to 38 °F (1 °C, 3 °C) | 36 °F/2 °C to 43 °F/6 °C | From '50℉' to '30℉'('10℃' to '-1℃') |
| Freezer factory setting | -20 °C (-4 °F) | -7°Fto -1 °F (-22 °C, -18 °C) | 0 °F/-18 °C | -8℉(-22℃) |
| Freezer adjustment range | -7 to -25 °C (19 to -13 °F) | -7°Fto -1 °F (-22 °C, -18 °C) | -11 °F/-24 °C to 11 °F/-12 °C | From '5℉' to '-17℉'('-15℃' to '-27℃') |
| Time to cool down | 1 hour | · | · | 24 hours |
| Clearance above | 30 cm (11.8 in) | 12" (30.5 cm) | 4“(102mm) | · |
| Space to open the doors | 120 cm (47.2 in) | · | · | · |
Similar Hoshizaki commercial refrigeration
| Hoshizaki COMMERCIAL FREEZER HFW 77 & 147 - Hoshizaki Europe | Instruction Manual | 32 pages |
|---|---|---|
| Hoshizaki Commercial Refrigeration Owner's Manual | Owner's Manual | 30 pages |
| Hoshizaki Instruction Manual - Wasserstrom | Owner's Manual | 23 pages |