Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Clearance above12”Above the condensing unitTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 5
Defrostautomaticall Traulsen unitsPredictive Defrost™Freezer modelsp. 9 p. 6

Traulsen AHT126WPUT-FHG questions

Answers taken from this manual. Each one links to the page it comes from.

The food compartment is too warm. What should I check?
  • Setpoint too high. Readjust the setpoint.
  • Dirty condenser coil. Clean the condenser coil properly.
  • Blocked airflow. Load product with proper airflow.
  • Poor door or gasket seal. Check alignment and sealing.
  • Warm food or prolonged door opening. Allow time for cabinet recovery.

Manual: page 12

How much clearance does the refrigerator need above the condensing unit?

At least 12” above the condensing unit is required, unless unrestricted airflow is provided at the back. This space also permits certain maintenance tasks.

Manual: page 5

How do I replace the door gasket?
  1. Pull the old gasket out by one corner.
  2. Bring the unit and replacement gasket to room temperature.
  3. Seat the four corners first with a rubber mallet or hammer with a wood block.
  4. Tap from both ends toward the center until the gasket is fully seated.

Manual: page 7

How do I clean the door gasket?

Clean the gasket with baking soda and water, mixed at 1 tablespoon baking soda : 1 pint water.

Manual: page 7

Do I need to manually defrost this refrigerator or freezer?

No. Refrigerators defrost every 8 hours, while freezers use Predictive Defrost™ only when operating conditions require it.

Manual: page 6

What does the defrost indicator mean?

It indicates a defrost cycle: the control shows the cabinet temperature from when defrost began and activates the defrost symbol LED.

Manual: page 6

How do I check and clear the power-failure alarm?

Use the alarm menu to review the outage duration, restoration temperature, and alarm status.

  1. Press Unlock / Modify twice to open the keypad.
  2. From the cabinet-temperature screen, press Display / Enter; SEn appears.
  3. Use Plus (+) or Minus (-) until Al appears.
  4. Press Display / Enter to open the alarm menu.
  5. Select tPd to view how long power was off.
  6. Select tCu to view the temperature when power returned.
  7. Select PFA, then press Display / Enter twice until nor appears.
  8. Press Escape /Back / Cancel twice to leave the submenu.

Manual: page 10

How do I turn a hot food unit back on?
  1. Press Escape /Back / Cancel until the screen is blank.
  2. Press any key to switch the unit back on.

Manual: page 10

What does the alarm indicator mean?

The Alarm / Door Open indicator shows an alarm or door-open status.

Manual: page 8

Similar Traulsen commercial refrigeration

Traulsen AHT126WPUT-FHGModel family AHT126WPUTFHGService Manual40 pages
Traulsen AHT126WPUT-FHGModel family AHT126WPUTFHGOwner's Manual26 pages